Extron electronic manual Standard MLC 52 with a type B remote control

Page 43

Standard MLC 52 with a type B remote control

If you are using an MLC 52 IR or an MLC 52 RS with a type B remote control, program the buttons using the following scheme:

COMPUTER VIDEO

VIDEO AUDIO A/V

MUTE MUTE MUTE

MENUENTER

CONT/ COL/

SIZE CENTER BRT TINT

SHARP

PHASE

ASPECT

RATIO

PROJECTOR

ON

OFF

VOL

PC

 

VOL

VIDEO

 

 

MLC 52

Command 1: Computer The button should be in input switch mode.

Command 2: Video The button should be in input switch mode.

Projector Remote Control Type B

Figure 33. Programming MLC 52 Input Selection Buttons from a Projector Remote Control Type B

MLC 52 VC models with a type B remote control

If you are using an MLC 52 IR VC or an MLC 52 RS VC with a type B remote control, program the buttons using the following scheme:

COMPUTER VIDEO

VIDEO AUDIO A/V

MUTE MUTE MUTE

MENUENTER

CONT/ COL/

SIZE CENTER BRT TINT

SHARP

PHASE

ASPECT

RATIO

VOLUME

Leave blank and do not program. The button should be in single switch mode.

Leave blank and do not program. The button should be in single switch mode.

DISPLAY

ON

OFF

PC

VIDEO

Command 1: Computer The button should be in input switch mode.

Command 1: Video. The button should be placed in input switch mode.

Projector Remote ControlType B

MLC 52

Figure 34. Programming MLC 52 IR VC and MLC 52 RS VC with a Projector Remote Control Type B

Programming Buttons for Multiple Inputs on an RS-232 Controlled System

If the MLC 52 RS will control the projector via RS-232, you do not need to use the projector remote control. Program the MLC buttons directly via the front panel configuration port using the configuration software (see the configuration program help file for instructions on programming RS-232 commands to MLC buttons).

1.Program commands 1 and 2 on the PC and Video buttons with the projector RS-232 command for discrete input selection. The MLC now has two commands each on the PC and Video buttons.

2.Press the buttons repeatedly to switch between the two input selection commands that you entered on each button.

MLC 52 MediaLink Controllers • Special Applications

37

Image 43
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeNotifications Specifications AvailabilitySoftware Commands Conventions Used in this GuideContents Reference Information Serial CommunicationModels IntroductionAbout this Guide About the MLC 52 Series MediaLink ControllersEuropean models Standard FeaturesMK models MLC 52 Configuration Software Options and AccessoriesDevice Drivers Application DiagramsSystem Requirements MLC 52 RS VC Rear Panel and Cable Connections Installation ConfigurationMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLWiring the Power Connector Configuring the MLC 52 Using IRConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCMounting the MLC Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureButtons on the Front Panel Front Panel FeaturesSwitch modes OperationMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLC Programming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Using the MLC 52/DVCM 50 Configuration Program Configuration PortsSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Host-to-Controller Communications Using SIS CommandsUsing the Command and Response Table Error ResponsesSymbol Definitions Command and Response Table for SIS Commands Included Parts Part Numbers and AccessoriesIncluded Parts Replacement Part Number Reference InformationRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty
Related manuals
Manual 124 pages 24.39 Kb