Extron electronic MLC 52 manual Programming RGB inputs projector remote control type B

Page 49

Configuration for a System with a Projector Remote Control Type B (Application 3)

A type B remote control has only two input buttons: one for the RGB inputs and one for the S-video and composite video inputs (see page 34). Each of these buttons contains two commands (“A” and “B”) that cause the button to toggle between inputs.

Following these steps, use IR learning to program the input selection commands from the projector type B hand-held remote control onto the MLC PC and Video or blank (VC models) buttons.

Programming RGB inputs — projector remote control type B

1.Place the rear panel configuration DIP switch 1 in the On (up) position to enter learning mode.

ON

 

 

 

1

2

3

4

2.Using IR learning, program command “A” from the RGB input selection button on the projector remote control into memory block 1 of the MLC 52 PC button as follows:

a.Press the PC button on the MLC front panel. The button blinks, indicating that the MLC is ready to learn the command. On the rear panel, the bottom IR Learning LED flashes.

b.Within 5 seconds (while the PC button on the MLC 52 is blinking), press the RGB button on the projector remote control. The MLC learns command “A” for RGB.

3.Program the input selection command “B” from the RGB input selection button on the projector remote control into memory block 2 of the MLC 52 PC button as follows:

a.Press the PC button on the MLC front panel. The button blinks, indicating that the MLC is ready to learn the command. On the rear panel, the second LED from the bottom flashes.

b.Within 5 seconds (while the PC button on the MLC 52 is blinking), press the RGB button on the projector remote control. The MLC learns command “B” for RGB.

4.If finished programming the MLC 52 buttons, return configuration DIP switch 1 to its Off (down) position, and test the system.

If you want to program video input selection at this time, proceed to Programming video inputs — projector remote control type B.

Programming video inputs — projector remote control type B

COMPUTER

VIDEO

VIDEO

AUDIO

A/V

MUTE

MUTE

MUTE

MENU

 

ENTER

CONT/ COL/

SIZE CENTER BRT TINT

SHARP

PHASE

ASPECT

RATIO

 

DISPLAY

ON

OFF

VOL

PC

 

VOL

VIDEO

 

Command 1: RGB / IR Command “A”

Command 2: RGB / IR Command “B”

Command 1: Video / IR Command “A”

Command 2: Video / IR Command “B”

MLC 52

Projector Remote Type B

Figure 39. Programming MLC 52 Input Selection Buttons from a Projector Remote Control Type B

MLC 52 MediaLink Controllers • Special Applications

43

Image 49
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeSoftware Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Reference Information Serial CommunicationAbout this Guide IntroductionAbout the MLC 52 Series MediaLink Controllers ModelsEuropean models Standard FeaturesMK models MLC 52 Configuration Software Options and AccessoriesDevice Drivers Application DiagramsSystem Requirements MLC 52 RS VC Rear Panel and Cable Connections Installation ConfigurationMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLWiring the Power Connector Configuring the MLC 52 Using IRConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCMounting the MLC Configuring the MLC 52 IR VC and MLC 52 RS VC Vol ButtonsPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureSwitch modes Front Panel FeaturesOperation Buttons on the Front PanelMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Using the MLC 52/DVCM 50 Configuration Program Configuration PortsSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Using the Command and Response Table Using SIS CommandsError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Included Parts Replacement Part Number Part Numbers and AccessoriesReference Information Included PartsRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty