Extron electronic manual Options and Accessories, MLC 52 Configuration Software

Page 9

Inactivity timer for display shutoff — Adjustable timer control provides automatic shutdown of the display device to conserve energy, prevent plasma burn-in, and extend projector lamp life.

Front panel security lockout — Front panel lockout (executive mode) can be implemented where the MLC 52 is installed in an unsecured environment and universal access is not desirable.

Flexible mounting options — With a standard electrical box or one of the included mounting brackets (“mud rings”), the MLC 52 can be mounted in a variety of locations, including walls and lecterns.

Volume control (VC) faceplates — The two-gang sized VC models each have an integrated volume control knob in addition to the six control buttons. To use this knob, connect the MLC 52 to a power amplifier (purchased separately), such as the Extron MPA Series Mini Power Amplifier that is also connected to the projector or display (see the application diagrams on page 4). The volume control knob adjusts the volume on the amplifier.

This option frees the two volume control buttons on the MLC to be used or reconfigured for other display device functions. On these models, the two buttons normally used for volume control on the standard MLC 52 models can be programmed to control additional outputs or other projector or display functions.

Section 508 Compliant — The MLC 52 meets or exceeds accessibility standards for Electronic Information Technology. For more information about the Extron Commitment to Accessibility, see the Accessibility at Extron web page at www.extron.com/company/article.aspx?id=accessibility.

Power supply — A 12 V, 1 A, external universal ENERGY STAR® qualified power supply, part number 70-775-01, is included and provides worldwide compatibility, low power consumption, and reduced operating costs.

NOTE: The Extron PS 124 and other Extron power supplies can also be used with the MLC 52.

Options and Accessories

MPA Series Mini Power Amplifier — Connect an MPA 152 (part number

60-844-01) to the volume control port of the MLC 52 VC models, and to your projector or display and speakers. This enables you to use the MLC volume knob to control the volume of the speakers via the MPA.

Remote control — The optional IRL 20 signal repeater provides infrared remote control of the MLC unit from up to 30 feet (9.1 m) away. The signal repeater works with any Extron hand-held IR remote control.

MLC 52 Configuration Software

The included MLC 52/DVCM 50 Configuration Program is used to configure the MLC buttons and ports via an RS-232 connection. This software, provided on a DVD that is delivered with the product, enables you to set functions for the front panel buttons and to configure the MLC ports in order to control devices via the MLC. The software works in combination with the IR or RS-232 drivers, also provided with the MLC on DVD or at www.extron.com (see Installing the Software from the DVD on page 48 to access this program).

MLC 52 MediaLink Controllers • Introduction

3

Image 9
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeSoftware Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Reference Information Serial CommunicationAbout this Guide IntroductionAbout the MLC 52 Series MediaLink Controllers ModelsStandard Features European modelsMK models MLC 52 Configuration Software Options and AccessoriesApplication Diagrams Device DriversSystem Requirements MLC 52 RS VC Installation Configuration Rear Panel and Cable ConnectionsMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLConfiguring the MLC 52 Using IR Wiring the Power ConnectorConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCConfiguring the MLC 52 IR VC and MLC 52 RS VC Vol Buttons Mounting the MLCPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureSwitch modes Front Panel FeaturesOperation Buttons on the Front PanelMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Configuration Ports Using the MLC 52/DVCM 50 Configuration ProgramSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Using the Command and Response Table Using SIS CommandsError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Included Parts Replacement Part Number Part Numbers and AccessoriesReference Information Included PartsRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty