4.Put the MLC Off button that you have just programmed into macro mode by pressing and holding the button for 3 seconds. The orange LED on the back panel, labeled “E,” flashes rapidly five times, then turns off, indicating that the button is now configured for macro mode.

5.Set configuration DIP switch 1 on the MLC rear panel to Off (down).

Now, with one press of the MLC Off button, you can issue the command to projector off and respond to the projector confirmation prompt. The commands are issued in succession at 1.5-second intervals.

Application 3: Controlling Projectors That Have Multi-coded IR Functionality

Certain projectors, such as Philips projectors, have multiple IR codes for the same function. Projectors with multi-coded IR functionality issue two commands for each IR remote control button. Command “A” is initiated by the first press of the button; command “B” is initiated by the second press. Because the buttons on the MLC 52 can store up to four commands, it is ideal for projectors of this type.

If controlled via RS-232, projectors that have multi-coded IR functions typically have a specific RS-232 command that selects or performs each desired function. Therefore, there is no command “A” or “B” for RS-232 control.

This section provides instructions for using IR learning to program multiple input selection commands onto the MLC 52 buttons from two common types of hand-held projector remote controls that have multi-coded IR functionality.

NOTE: For best results, select a projector that has a dedicated audio and video input

for each source used in the system. Video and audio should not share an input.

Configuration for a System with a Projector Remote Control Type A (Application 3)

A type A remote control has a discrete button for each input (see page 34). Two buttons are designated for RGB inputs, one for S-video, and one for video (composite). Each of these input selection buttons on the type A remote control has a command “A” and “B” coded on it. Follow these steps to use IR learning to program the input selection commands from the projector type A hand-held remote control onto the MLC PC and Video buttons.

NOTE: When a command has been successfully learned, the IR learning LEDs on the MLC rear panel flash in rapid progression from top to bottom, then back to top.

Programming RGB inputs — projector remote control type A

1.Place the rear panel configuration DIP switch 1 in the On (up) position to enable learning mode.

ON

 

 

 

1

2

3

4

2.Using IR learning, program command “A” from the RGB 1 input selection button on the projector remote control into memory block 1 of the MLC PC button:

a.Press the PC button on the MLC front panel. The button blinks, indicating that the MLC is ready to learn the command. On the rear panel, the bottom IR learning LED should be flashing.

b.Within 5 seconds (while the PC button on the MLC 52 is blinking), press the RGB 1 button on the remote control. The MLC learns command “A” for RGB 1.

MLC 52 MediaLink Controllers • Special Applications

39

Image 45
Contents MLC 52 Series Safety Instructions English Chinese Simplified(简体中文) Safety InstructionsTrademarks FCC Class a NoticeSoftware Commands Specifications AvailabilityConventions Used in this Guide NotificationsContents Reference Information Serial CommunicationAbout this Guide IntroductionAbout the MLC 52 Series MediaLink Controllers ModelsStandard Features European modelsMK models MLC 52 Configuration Software Options and AccessoriesApplication Diagrams Device DriversSystem Requirements MLC 52 RS VC Installation Configuration Rear Panel and Cable ConnectionsMLC MLC 52 RS EU and MLC 52 RS EU VC Rear Views MLC 52 RS MK VC MLC 52 RS MK and MLC 52 RS MK VC Rear ViewsInstallation Steps Replacing the Faceplate US Models Only Screws to Remove from the MLC Faceplate Replacing Button LabelsRemoving and Replacing a Button Label Wiring for RS-232 Control RS Models Only Wiring the Control ConnectorWiring for IR Control Wiring an IRL Wiring an IRLConfiguring the MLC 52 Using IR Wiring the Power ConnectorConfiguring Using IR Data Transfer IR Beaming Data Transfer Percent Complete MLC 52 Models MLC 52 VC Models Buttons Lit Order in which the Buttons Blink during Data TransferActivation of LEDs During Button Configuration Configuring Using IR LearningRemoving IR Commands from a Button Setting Up Button Macros Using IR Wiring the VC Port Setting Up an MLC 52 VC Model with an Extron AmplifierExtron MPA Requirements for the MLC 52 VCConfiguring the MLC 52 IR VC and MLC 52 RS VC Vol Buttons Mounting the MLCPreparing the Site Mounting the MLC to an Electrical Box Mounting the MLC 52 to an Electrical Box Mounting the MLC to a Decora Mounting BracketMounting an MLC 52 to a Decora Mounting Bracket Mounting the MLC to a Wall or FurnitureSwitch modes Front Panel FeaturesOperation Buttons on the Front PanelMLC 52 IR and RS MLC 52 IR VC and RS VC Front Panel ComponentsMLC 52 RS Mkmlc 52 RS MK VC Mm TRS Cable for the Configuration Port Input Selection Buttons on the MLC 52 Front Panel Selecting InputsLocking the Front Panel Executive Mode ResettingSpecial Applications Application 1 Using Multiple Sources with an MLCProgramming Buttons for an IR Controlled System Examples of Projector Remote Control Types a and BStandard MLC 52 models with a type a remote control Projector remote control type a applicationMLC 52 VC models with a type a remote control Projector remote control type B applicationStandard MLC 52 with a type B remote control Turn Power OFF? Yes Press Again No Please Wait Programming RGB inputs projector remote control type a Programming video inputs projector remote control type a Projector Remote Type a Using the Video button S-video or composite video Using the PC button RGBProgramming video inputs projector remote control type B Programming RGB inputs projector remote control type BProjector Remote Type B Using the PC button RGB Configuration Ports Using the MLC 52/DVCM 50 Configuration ProgramSerial Communication Extron Software DVD Screen Installing the Software from the DVDControl Software Button on Download Center Screen Downloading and Installing the Software from the WebsiteSelect a Comm Port Tab Starting the Configuration ProgramMLC 52/DVCM 50 Configuration Program Window Loading the serial RS-232 drivers Loading Extron DriversSelecting the MLC 52/DVCM 50 IR Driver Package Downloading IR drivers from the DVDIR Device Drivers Package List Saving a Single Driver to the Computer To download a single driverDevice Drivers Screen Downloading drivers from the websiteEntering MLC 62 Driver Search Criteria Using the Command and Response Table Using SIS CommandsError Responses Host-to-Controller CommunicationsSymbol Definitions Command and Response Table for SIS Commands Included Parts Replacement Part Number Part Numbers and AccessoriesReference Information Included PartsRecommended Cables Optional AccessoriesMounting an Electrical Box Attaching an Electrical Box to a Wall Stud Templates for MLC 52 and MLC 52 VC US ModelsMLC MLC 52 VC Surface CUT-OUT Area For Furniture Mount 50 8.90 cm 40 cm Extron Warranty