Setting the Internet Protocol (IP) Address

The IPL T S Series units have a factory default IP address of 192.168.254.254. This IP address must be changed to an address that will operate on your local network.

There are three ways to change the IP address setting:

Add Device > Auto Config IP option in Global Configurator

IPL T S unit’s embedded Web pages

Address Resolution Protocol (ARP) command

Before you begin:

1.

Obtain a valid IP address for your IPL T S Series device from your A/V

 

system’s network administrator.

2.

Write down the unit’s MAC address (a 12-digit number) found on a label on

 

the rear panel of the unit (for example, 00-05-A6-01-0A-74).

3.

If the unit is not at it’s factory default IP address (192.168.254.254), perform a

 

Mode 4 reset:

 

a.

Hold down the Reset button until the Power LED blinks twice

 

 

(6 seconds), then release.

 

b.

Press and release the Reset button again within 1 second.

 

 

The Power LED blinks quickly four times, confirming the Mode 4 reset,

 

 

which returns the unit to its factory default IP address.

IPL T S Series • Connection and Configuration

3-3

Image 27
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One Introduction About This ManualAbout the IPL T S Series Interface IPL T S6 FeaturesIntroduction, cont’d Two Mounting the IPL T S Interface Installation and OperationInstallation Overview IPL T S Series Installation and OperationMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationFront panel indicators OperationIdentification 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/Summary Installation and Operation, cont’d Three Ethernet connection Connection and ConfigurationConnecting the Hardware IPL T S Series Connection and ConfigurationIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesConfiguration System SettingsSystem Status Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four IPL T S Series Communication and Control Using the command/response tableCommunication and Control Programmer’s Guide for Telnet and Web BrowsersIPL T S Series Communication and Control Copyright information Password informationError responses Ascii to Decimal Conversion Table CommunicationBidirectional serial data port Series Communication and Control X!*X3,X3!CF  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X2CYEthernet data port X5,X5#,X2X6 TC Series Communication and ControlX1!  SeriesFirmware version, part number and information requests  X4%SM  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR X4, X4&  X1& ,X1% CM WX1$ %2CX1% CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM IpmX1$ ,X1% ,X7# ,X7$X1#  X1@CNX1@  X1#CTX6$,X1$  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$   X6$ EB X5@ Password and security settings X3# CA  X3# CU WX3# CUWMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Customization Custom Web pagesServer Side Includes SSI Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingSerial pass-through redirect mode Advanced Serial Port ControlUnsafe characters IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationTroubleshooting Power connectionsData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories EMI/EMC Accessories Part number Part Numbers and AccessoriesOptional accessories Included parts Replacement part NumberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron USA West