Extron electronic IPL T S manual  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM,  X1$ ,X1% ,X7# ,X7$ CM

Page 51

IPL T S Series • Communication and Control 4-11

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

Send e-mail (using

E X4%,X7),X4&SM}

WX4%%2CX7)%2CX4&SM

EmlX4%]

X7) = The number to insert into an e‑mail

 

 

 

 

____

 

 

 

 

server-side include “<!--#echo var =

 

 

 

 

“WCR-->” (the E} command with

 

 

 

 

no parameters.) The numeral is a 16-bit

 

 

 

 

number to be employed as the user defines.

 

 

 

 

This is an optional parameter. Use 0 as a

 

 

 

 

placeholder if the optional X4& variable is

 

 

 

 

used but X7) is not needed.

 

 

 

 

X4& = xxx, where xxx = a number 1 to 999

 

 

 

 

corresponding to the e-mail’s filename (xxx.

 

 

 

 

eml). If xxx = 0 or no parameter is given, the

 

 

 

 

IPL T S unit sends the file that was set via the

 

 

 

 

CR command.

NIf file X4&.eml is not found when the SM command is executed, the MLC sends a default e-mail message.

Set e-mail server IP

EX1$,X1%,X7#,X7$ CM}

W X1$%2C X1% %2C X7# %2C X7$

 

X1$ = IP address (xxx.xxx.xxx.xxx). Leading

Ipm•X1$,X1%,X7#,X7$]

address and user

 

%2C CM

 

zeros are optional in setting values. Leading

 

 

domain name24

 

 

 

zeros are suppressed in returned values.

 

 

 

 

X1% = E-mail domain name, e.g., extron.com

 

 

 

 

X7# = An e-mail account username (for

 

 

 

 

SMTP authentication) of up to 31 characters.

 

 

 

 

Do not use commas. This parameter is

 

 

 

 

optional during setup.

 

 

 

 

X7$ = An e-mail account password (for

 

 

 

 

SMTP authentication) of up to 31 characters.

 

 

 

 

Do not use commas. This parameter is

 

 

 

 

optional during setup. In a response,

 

 

 

 

instead of the actual password, X7$ is

 

 

 

 

displayed as 4 asterisks (****) if a password

 

 

 

 

has been set up or as nothing (      ) if it has

 

 

 

 

not.

Mail server setup

Set mail server IP, unit

E X1&,X1%CM]

WX1$%2CX1%CM

Ipm•X1$,X1%]

domain name24

 

 

 

View mail server IP,

ECM}

WCM

X1$,X1%]

unit domain name

 

 

 

different file)

24

message if a

.

eml file has an embedded

Image 51
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One Introduction About This ManualAbout the IPL T S Series Interface IPL T S6 FeaturesIntroduction, cont’d Two Mounting the IPL T S Interface Installation and OperationInstallation Overview IPL T S Series Installation and OperationMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationFront panel indicators OperationIdentification 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Ethernet connection Connection and ConfigurationConnecting the Hardware IPL T S Series Connection and ConfigurationIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesConfiguration System SettingsSystem Status Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four IPL T S Series Communication and Control Using the command/response tableCommunication and Control Programmer’s Guide for Telnet and Web BrowsersIPL T S Series Communication and Control Copyright information Password informationError responses Ascii to Decimal Conversion Table CommunicationBidirectional serial data port Series Communication and Control X!*X3,X3!CF  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X2CYEthernet data port X5,X5#,X2X6 TC Series Communication and ControlX1!  SeriesFirmware version, part number and information requests  X4%SM  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR X4, X4&  X1& ,X1% CM WX1$ %2CX1% CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM IpmX1$ ,X1% ,X7# ,X7$X1#  X1@CNX1@  X1#CTX6$,X1$  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$   X6$ EB X5@ Password and security settings X3# CA  X3# CU WX3# CUWMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Customization Custom Web pagesServer Side Includes SSI Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingSerial pass-through redirect mode Advanced Serial Port ControlUnsafe characters IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationTroubleshooting Power connectionsData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories EMI/EMC Accessories Part number Part Numbers and AccessoriesOptional accessories Included parts Replacement part NumberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron USA West
Related manuals
Manual 6 pages 25.01 Kb

IPL T S specifications

The Extron Electronics IPL T S is a powerful tool designed for seamless integration and control in AV applications. It provides a complete AV control solution that is highly intuitive and customizable. With its diverse set of features, the IPL T S caters to various environments, from educational institutions to corporate settings, delivering functionality and flexibility.

One of the standout features of the IPL T S is its user-friendly interface, which allows users to easily navigate through different control options. The device supports customizable touchscreen control, enabling users to personalize layouts according to their specific needs. This adaptability not only enhances user experience but also increases efficiency during presentations or meetings.

The technology behind the IPL T S includes advanced network control capabilities. It utilizes Extron’s well-rounded Global Viewer® technology, allowing users to manage and monitor their AV systems through a web-based application. This feature is crucial for IT managers or AV administrators who need real-time insight into the performance and status of their equipment, ensuring seamless operation.

Connectivity is another critical aspect of the IPL T S. It supports various control protocols, including IP, RS-232, and USB, making it compatible with a wide range of third-party devices. This compatibility not only simplifies integration but also offers users the flexibility to expand their AV systems as needed.

Moreover, the IPL T S is designed with robust security features, ensuring that control systems remain secure from unauthorized access. This is particularly important in corporate environments where sensitive information may be presented during meetings.

The device is built with reliability in mind, featuring Extron’s renowned quality assurance processes. It’s designed for uninterrupted performance, ensuring that users can rely on it during critical situations. Additionally, the IPL T S is backed by Extron’s extensive technical support, providing users with peace of mind.

In summary, the Extron IPL T S is an advanced, versatile AV control solution that greatly enhances the user experience in various settings. With its intuitive interface, extensive connectivity options, robust security features, and reliable performance, it stands out as an essential tool for modern AV applications, streamlining control and enabling effective communication.