If the correct password is entered, the unit responds with “]Login Administrator ]” or “]Login User]”, depending on the password entered. If the passwords are the same for both administrator and user, the unit defaults to administrator privileges.
Error responses
When the IPL T S interface receives a valid command, it executes the command and sends a response to the host device. If the unit is unable to execute the command because the command contains invalid parameters, it returns an error response to the host.
E12 — Invalid port number
E13 — Invalid parameter
E14 — Not valid for this configuration
E17 — System timed out
E22 — Busy
E24 — Privilege violation
E25 — Device not present
E26 — Maximum number of connections exceeded
E27 — Invalid event number
E28 — Bad filename/file not found
E31 — Attempt to break port
References to errors (at command descriptions on the following pages)
13= Commands that give an E13 (invalid parameter) error
24= Commands that give an E24 (privilege violation) error if not administrator level
27= Commands that may give an E27 (invalid event number) error
28= Commands that may give an E28 (file not found) error
IPL T S Series • Communication and Control |