| Figure 3-6 — Web server System Settings screen |
To return the local PC to its original TCP/IP settings: |
1. | Close the Web browser. |
2. | Disconnect the Ethernet crossover cable from the PC and the device. |
3. | Return to the TCP/IP Properties dialog box on the PC. |
4. | Return the IP address, Subnet mask, Default gateway, and DHCP fields to |
| their original settings. |
5. | Reboot the PC. |
Setting the IP address using the ARP command
An IPL T S unit’s IP address can be set using the DOS Address Resolution Protocol (ARP) command.
The IPL T S unit must be:
•physically connected to the network
•at its factory default IP address
To set an IP address using the ARP command:
1. | Open a command prompt window on a local PC. On Windows XP, a |
| command prompt window can be found at: |
| Start > All Programs > Accessories > Command Prompt |
2. | At the command prompt type: |
| arp - s<IP address><MAC address> |
example: C:\>arp -s 10.13.197.64 00-05-A6-00-30-5F
The example command assigns IP address 10.13.197.64 to the device that has a MAC address of 00-05-A6-00-30-5F.
IPL T S Series • Connection and Configuration | 3-7 |
Contents
IP Link Ethernet Control Interfaces
IPL T S Series
Sicherheitsanleitungen Deutsch
Precautions
Safety Instructions English
Consignes de Sécurité Français
FCC Class a Notice
IPL T S Series
Ii IPL T S Series
IPL T S Series Quick Start QS-1
Quick Start IPL T S Series
QS-2 IPL T S Series Quick Start
Table of Contents
Table of Contents, cont’d
One
About This Manual
Introduction
About the IPL T S Series Interface
IPL T S6
Features
Introduction, cont’d
Two
Mounting the IPL T S Interface
Installation and Operation
Installation Overview
IPL T S Series Installation and Operation
Rack mounting an IPL T S Series interface
Mounting options
Mounting Type Kit PN
Furniture or projector mounting
Installation and Operation, cont’d
Mounting the interface
Rear Panel Features and Cabling
Section A-A
Power
Serial Communication
Ethernet/LAN
Pin Function RS-232 RS-422 RS-485
IPL T S Series Installation
Operation
Front panel indicators
Identification
13 IPL T S4 front panel
Resetting the unit
Mode Activation Result
Reset Mode Comparison/Summary
Installation and Operation, cont’d
Three
Ethernet connection
Connection and Configuration
Connecting the Hardware
IPL T S Series Connection and Configuration
IPL T S4
Setting the Internet Protocol IP Address
Setting the IP address using Global Configurator
Connection and Configuration, cont’d
Setting the IP address in Global Configurator
Setting the IP address using embedded Web pages
Internet Protocol TCP/IP Properties dialog box
Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F
Setting the IP address using the ARP command
Click the Download GCSW3XX.exe button
Configuration using Global Configurator
Global Configurator
Configuration using Embedded Web Pages
Web server Password dialog box
Connecting via the Web server pages
System Settings
Configuration
System Status
Port Settings
12 System Settings screen
Email Alerts
Passwords
File Management
Firmware Upgrade
Click the Control Software icon
Configuration using DataViewer
19 Communication Setup dialog box
Four
IPL T S Series Communication and Control
Using the command/response table
Communication and Control
Programmer’s Guide for Telnet and Web Browsers
IPL T S Series Communication and Control
Copyright information
Password information
Error responses
Ascii to Decimal Conversion Table
Communication
Bidirectional serial data port
Series Communication and Control
X!*X3,X3!CF
X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2
X2%, X2, X2&, X2
X!*X2CY
Ethernet data port
X5,X5#,X2
X6 TC
Series Communication and Control
Series
X1!
Firmware version, part number and information requests
X4%SM
X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&
X4%CR
X4, X4&
X1& ,X1% CM WX1$ %2CX1% CM
X4%,X7,X4&SM WX4%%2CX7%2CX4&SM
X1$ ,X1% ,X7# ,X7$ CM
IpmX1$ ,X1% ,X7# ,X7$
X1#
X1@CN
X1@
X1#CT
X6$,X1$
X2@
X6$,X1$ EB WX6$%2CX1$EB Bmd X6$,X1$
X6$ EB
X5@
Password and security settings
X3# CA
X3# CU WX3# CU
WMT
Remap port designations
ECJ WCJ
Directories
Stream files via Telnet or RS-232
EDF
ZQQQ
Custom Web pages
Customization
Server Side Includes SSI
Query string
Server Side Include Using a Remote SIS command
Example
Code examples
6b Browser view of previous Html source code
Reserved characters
URL encoding
Advanced Serial Port Control
Serial pass-through redirect mode
Unsafe characters
IPL T S2
Direct port access ports 2001 through
Hardware connection
Serial Bridging
IPL T S4
Serial bridge configuration
Power connections
Troubleshooting
Data connections
IPL T S Series Communication and Control
Communication and Control, cont’d
Specifications, Part Numbers, Accessories
Specifications
Specifications, Part Numbers, Accessories
IPL T S Series Specifications, Part Numbers, Accessories
EMI/EMC
Accessories Part number
Part Numbers and Accessories
Optional accessories
Included parts Replacement part Number
Appendix B
Glossary
Glossary
IPL T S Series Glossary
IPL T S Series Glossary
Extron’s Warranty
Extron USA West