Extron electronic IPL T S manual Setting the IP address using the ARP command

Page 31

 

Figure 3-6 — Web server System Settings screen

To return the local PC to its original TCP/IP settings:

1.

Close the Web browser.

2.

Disconnect the Ethernet crossover cable from the PC and the device.

3.

Return to the TCP/IP Properties dialog box on the PC.

4.

Return the IP address, Subnet mask, Default gateway, and DHCP fields to

 

their original settings.

5.

Reboot the PC.

Setting the IP address using the ARP command

An IPL T S unit’s IP address can be set using the DOS Address Resolution Protocol (ARP) command.

The IPL T S unit must be:

physically connected to the network

at its factory default IP address

To set an IP address using the ARP command:

1.

Open a command prompt window on a local PC. On Windows XP, a

 

command prompt window can be found at:

 

Start > All Programs > Accessories > Command Prompt

2.

At the command prompt type:

 

arp - s<IP address><MAC address>

example: C:\>arp -s 10.13.197.64 00-05-A6-00-30-5F

The example command assigns IP address 10.13.197.64 to the device that has a MAC address of 00-05-A6-00-30-5F.

IPL T S Series • Connection and Configuration

3-7

Image 31
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About This Manual IntroductionAbout the IPL T S Series Interface IPL T S6 FeaturesIntroduction, cont’d Two Mounting the IPL T S Interface Installation and OperationInstallation Overview IPL T S Series Installation and OperationRack mounting an IPL T S Series interface Mounting optionsMounting Type Kit PN Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationOperation Front panel indicatorsIdentification 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Ethernet connection Connection and ConfigurationConnecting the Hardware IPL T S Series Connection and ConfigurationIPL T S4 Setting the Internet Protocol IP Address Setting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Settings ConfigurationSystem Status Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four IPL T S Series Communication and Control Using the command/response tableCommunication and Control Programmer’s Guide for Telnet and Web BrowsersIPL T S Series Communication and Control Copyright information Password informationError responses Ascii to Decimal Conversion Table CommunicationBidirectional serial data port Series Communication and Control X!*X3,X3!CF  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X2CYEthernet data port X5,X5#,X2X6 TC Series Communication and ControlSeries X1! Firmware version, part number and information requests  X4%SM  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR X4, X4&  X1& ,X1% CM WX1$ %2CX1% CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM IpmX1$ ,X1% ,X7# ,X7$X1#  X1@CNX1@  X1#CTX6$,X1$  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$   X6$ EB X5@ Password and security settings X3# CA  X3# CU WX3# CUWMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Custom Web pages CustomizationServer Side Includes SSI Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingAdvanced Serial Port Control Serial pass-through redirect modeUnsafe characters IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationPower connections TroubleshootingData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications Specifications, Part Numbers, AccessoriesIPL T S Series Specifications, Part Numbers, Accessories EMI/EMC Accessories Part number Part Numbers and AccessoriesOptional accessories Included parts Replacement part NumberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron USA West
Related manuals
Manual 6 pages 25.01 Kb