Extron electronic IPL T S  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2, X2%, X2, X2&, X2 

Page 47

IPL T S Series • Communication and Control 4-7

Command

ASCII (Telnet)

URL Encoded (Web)

Response

 

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configure

E X!* X2%, X2^, X2&, X2*CP}

WX! %2A X2% %2CX2^ %2CX2&

Cpn X!•CcpX2%, X2^, X2&,

 

Set baud rate (X2%), parity (X2^), data bits

parameters24

 

%2CX2*CP 

X2*]

(X2&), and stop bits (X2*) for port X!.

 

 

 

 

 

X2% = 300, 600, 1200, 1800, 2400, 3600, 4800,

 

 

 

 

7200, 9600, 14400, 19200, 28800, 38400, 57600,

 

 

 

 

or 115200 baud.

 

 

 

 

 

 

X2^ = parity (only the first letter is needed):

 

 

 

 

 

Odd

 

 

 

 

 

 

E

 

ven

 

 

 

 

 

 

None (default)

 

 

 

 

 

 

M

 

ark

 

 

 

 

 

 

S

 

pace.

 

 

 

 

 

 

X2& = data bits: 7, 8

(default = 8).

 

 

 

 

 

X2* = stop bits: 1, 2

(default = 1).

Example:

E4*9600,N,8,1CP}

W4%2A9600%2CN%2C8%2C

Cpn4•Ccp9600,N,8,1]

 

Set the projector control port for 9600 baud,

 

 

1CP

 

 

no parity, 8 data bits, and 1 stop bit.

View parameters

E X!CP}

W X!CP

X2%, X2^, X2&, X2(]

 

 

 

 

 

 

Configure mode24

E X!*X2(CY}

WX!%2AX2(CY

CpnX!•CtyX2)]

 

 

 

 

 

 

View mode

E X!CY}

WX!CY

X2(]

 

 

 

 

 

 

Configure flow

E X!*X3),X3!CF}

WX!%2AX3)%2CX3!CF

CpnX!•CflX3), X3!]

 

 

 

 

 

 

control

 

 

 

 

 

 

 

 

 

View flow control

E X!CF}

WX!CF

X3), X3!]

 

 

 

 

 

 

Configure receive

E X!*X1&*X2)*X2#*X2!CE}

WX!%2AX1&%2AX2)%2AX2#

CpnX!•CceX1& , X2) , X2# , 

 

Set the time to wait (X1& = waiting time in

timeout24

 

%2AX2!CE

X2!]

tens of ms until receipt of the first response

 

 

 

 

character before terminating the receive

 

 

 

 

operation, X2) = waiting time in

 

 

 

 

 

tens of ms between characters before

 

 

 

 

 

terminating) and priority status

 

 

 

 

 

(X2#: 0 = default, use send data string

 

 

 

 

 

command parameters; 1 = use configure

 

 

 

 

 

receive timeout command parameters) for

 

 

 

 

 

port X!. X2! = #L or #D (see previous page).

 

 

 

 

 

The response includes leading zeros.

View receive timeout

E X!CE}

WX!CE

X1& , X2) , X2# , X2!]

 

 

 

 

 

 

Configure pass-thru

E X!*X5)*X5#*X2!CD}

WX!%2AX5)%2AX5#%2AX2!

CpnX!•CcdX5),X5#,X2!]

 

 

 

 

 

 

mode24

 

CD

 

 

 

 

 

 

 

Terminate pass-thru

E X!*0CD}

WX!%2A0CD

CpnX!•Ccd

 

 

 

 

 

 

mode24

 

 

00000,00000,00000L]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 47
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSicherheitsanleitungen Deutsch PrecautionsSafety Instructions English Consignes de Sécurité FrançaisFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About the IPL T S Series Interface IntroductionAbout This Manual IPL T S6 FeaturesIntroduction, cont’d Two Mounting the IPL T S Interface Installation and OperationInstallation Overview IPL T S Series Installation and OperationMounting Type Kit PN Mounting optionsRack mounting an IPL T S Series interface Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationIdentification Front panel indicatorsOperation 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Ethernet connection Connection and ConfigurationConnecting the Hardware IPL T S Series Connection and ConfigurationIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Status ConfigurationSystem Settings Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four IPL T S Series Communication and Control Using the command/response tableCommunication and Control Programmer’s Guide for Telnet and Web BrowsersIPL T S Series Communication and Control Copyright information Password informationError responses Ascii to Decimal Conversion Table CommunicationBidirectional serial data port Series Communication and Control X!*X3,X3!CF  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X2CYEthernet data port X5,X5#,X2X6 TC Series Communication and ControlFirmware version, part number and information requests X1! Series  X4%SM  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR X4, X4&  X1& ,X1% CM WX1$ %2CX1% CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM IpmX1$ ,X1% ,X7# ,X7$X1#  X1@CNX1@  X1#CTX6$,X1$  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$   X6$ EB X5@ Password and security settings X3# CA  X3# CU WX3# CUWMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Server Side Includes SSI CustomizationCustom Web pages Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingUnsafe characters Serial pass-through redirect modeAdvanced Serial Port Control IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationData connections TroubleshootingPower connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories IPL T S Series Specifications, Part Numbers, Accessories Specifications, Part Numbers, AccessoriesSpecifications EMI/EMC Accessories Part number Part Numbers and AccessoriesOptional accessories Included parts Replacement part NumberAppendix B IPL T S Series Glossary GlossaryGlossary IPL T S Series Glossary Extron’s Warranty Extron USA West