Extron electronic manual Quick Start IPL T S Series, IPL T S Series Quick Start QS-1

Page 5

Quick Start — IPL T S Series

Step 1

Turn power off and disconnect the device from its power source.

Step 4

Connect RS-232 cables from the IPL T S Series unit to the audio/video (A/V) devices.

Step 2

Mount the IPL T S Series unit:

• on a projector

Projector

MountingMounting

Bracket Bolt

Digital Projector

Projector Mount

• under a desk

Furniture Mount

IPL

 

TS2

 

R

COM

1

2

 

100 LINK ACT

• or on a rack

 

 

 

Rack Mount

IPLTS2

 

 

 

R

 

 

 

1 COM

 

 

 

2

 

 

 

100

IPLT

 

 

LINK

 

 

ACT

S2

 

 

 

R

COM

 

1U Rack Shelf

1

LINK

2

 

 

 

 

100

 

 

 

ACT

1/4 Rack Width False Front

 

 

Face Plate

 

 

 

IPLTS2

 

 

 

R

COM

 

 

1

Use 2 mounting holes on

2

 

 

LINK

 

 

 

100

opposite corners.

 

ACT

 

(2) 4-40 x 3/16" Screws

 

 

 

Step 3

Connect a local area network (LAN) cable from a PC, hub, or router to the IPL T S Series unit.

00-05-A6-00-30-06

 

 

COM1

 

 

 

POWER

LAN

 

 

COM2

 

 

 

12V

 

 

 

 

COM3

COM4 COM5

COM6

.5A MAX

 

 

 

 

 

 

 

TX RX

TX RX TX RX

TX RX

IPL T S6 Ethernet Control Interface

Step 5

Connect power cords and apply power in the following order:

output devices (projectors, monitors, speakers)

IPL T S Series device

PC or serial controller

input devices (DSS, cable boxes, and so on)

Step 6

Configure the IPL T S Series device. See chapter 3 for more information.

Step 7

Test the IPL T S Series device via its default Web pages. See chapter 4 for more information.

Extron

 

 

 

LAN

 

.5A MA

COM

1

 

IPL T S1

 

 

 

 

12V

 

X

 

 

Ethernet Control

 

RS-232

 

Interface

 

 

 

 

 

 

 

TCP/IP

 

 

 

 

Ethernet

Network

 

 

 

 

Plasma Display

Ethernet

Extron

 

 

 

LAN

 

.5A

MAX

1

 

 

 

 

COM

 

 

IPL T S1

12V

 

 

 

 

 

 

 

 

Remote User

Ethernet Control

 

 

 

 

 

 

RS-232

Control and

Interface

 

 

 

 

Administrator

 

 

 

 

 

Monitoring

Plasma Display

Typical IPL T S Series configuration

IPL T S Series • Quick Start QS-1

Image 5
Contents IP Link Ethernet Control Interfaces IPL T S Series Safety Instructions English Precautions Consignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About the IPL T S Series Interface IntroductionAbout This Manual IPL T S6 FeaturesIntroduction, cont’d Two Installation Overview Installation and OperationIPL T S Series Installation and Operation Mounting the IPL T S InterfaceMounting Type Kit PN Mounting optionsRack mounting an IPL T S Series interface Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationIdentification Front panel indicatorsOperation 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Connecting the Hardware Connection and ConfigurationIPL T S Series Connection and Configuration Ethernet connectionIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Status ConfigurationSystem Settings Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four Communication and Control Using the command/response tableProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlIPL T S Series Communication and Control Copyright information Password informationError responses Bidirectional serial data port CommunicationSeries Communication and Control Ascii to Decimal Conversion TableX2%, X2, X2&, X2   X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X!*X2CY  X!*X3,X3!CFX6 TC X5,X5#,X2Series Communication and Control Ethernet data portFirmware version, part number and information requests X1! Series  X4%CR  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4& X4, X4&   X4%SM X1$ ,X1% ,X7# ,X7$ CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CMX1@  X1@CN X1#CT X1# X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X2@  X6$ EB  X6$,X1$  X3# CA Password and security settings X3# CU WX3# CU X5@WMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Server Side Includes SSI CustomizationCustom Web pages Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingUnsafe characters Serial pass-through redirect modeAdvanced Serial Port Control IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationData connections TroubleshootingPower connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories IPL T S Series Specifications, Part Numbers, Accessories Specifications, Part Numbers, AccessoriesSpecifications EMI/EMC Optional accessories Part Numbers and AccessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B IPL T S Series Glossary GlossaryGlossary IPL T S Series Glossary Extron’s Warranty Extron USA West