Extron electronic IPL T S manual Connection and Configuration, Connecting the Hardware

Page 26

Connection and Configuration

Connecting the Hardware

To connect the IPL T S interface, connect the input and output devices to the unit. Use figure 3-1, below, as a guide.

Extron

IPL T S2

Ethernet Control Interface

 

093012052

UID#

 

LAN

POW

ER

 

12V MAX

.5A

 

TCP/IP

Network

1

COM

2

COM

COM

2

COM1

 

TX RX

TX RX

 

Serial Cables

to Controlled Devices (switcher, projector, etc.)

Ethernet

or

Crossover

Cable

PCLaptop

Figure 3-1 — IPL T S interface connections

Ethernet connection

Ethernet connection is used on an ongoing basis to connect the IPL T S unit to a LAN and to control the switching and display devices attached to the unit. To connect the unit to a LAN, do the following:

1.

Plug one end of a CAT 5, straight-through Ethernet cable into the rear panel

 

Ethernet connector on the IPL T S unit. See figure 2-9 in chapter 2 for

 

RJ-45 connector wiring information.

2.

Plug the other end of the Ethernet cable into a network switch or hub

 

connected to an Ethernet LAN or to the Internet.

3.

From your PC, launch a Web browser and type in the IP address previously

 

set up on the IPL T S (if this hasnt been set up, see “Setting the Internet

Protocol (IP) Address” later in this chapter). This displays the System Status Web page.

Serial connection

The IPL T S interface can be connected to any A/V device that has a serial control port.

1. Connect one end of a serial cable to the rear panel COM port connector of the IPL T S unit. As an alternative, use a 3.5 mm, 5-pole captive screw connector where available.

NThis captive screw connector must be wired appropriately. See figure 2-10 for pin assignments, if necessary.

3-2 IPL T S Series • Connection and Configuration

Image 26
Contents IPL T S Series IP Link Ethernet Control InterfacesConsignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschIPL T S Series FCC Class a NoticeIi IPL T S Series Quick Start IPL T S Series IPL T S Series Quick Start QS-1QS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About the IPL T S Series Interface IntroductionAbout This Manual Features IPL T S6Introduction, cont’d Two IPL T S Series Installation and Operation Installation and OperationInstallation Overview Mounting the IPL T S InterfaceMounting Type Kit PN Mounting optionsRack mounting an IPL T S Series interface Installation and Operation, cont’d Furniture or projector mountingRear Panel Features and Cabling Mounting the interfacePower Section A-AEthernet/LAN Serial CommunicationIPL T S Series Installation Pin Function RS-232 RS-422 RS-485Identification Front panel indicatorsOperation Resetting the unit 13 IPL T S4 front panel Reset Mode Comparison/Summary Mode Activation ResultInstallation and Operation, cont’d Three IPL T S Series Connection and Configuration Connection and ConfigurationConnecting the Hardware Ethernet connectionSetting the Internet Protocol IP Address IPL T S4Connection and Configuration, cont’d Setting the IP address using Global ConfiguratorSetting the IP address using embedded Web pages Setting the IP address in Global ConfiguratorInternet Protocol TCP/IP Properties dialog box Setting the IP address using the ARP command Example C\arp -s 10.13.197.64 00-05-A6-00-30-5FConfiguration using Global Configurator Click the Download GCSW3XX.exe buttonConfiguration using Embedded Web Pages Global ConfiguratorConnecting via the Web server pages Web server Password dialog boxSystem Status ConfigurationSystem Settings 12 System Settings screen Port SettingsPasswords Email AlertsFirmware Upgrade File ManagementConfiguration using DataViewer Click the Control Software icon19 Communication Setup dialog box Four Programmer’s Guide for Telnet and Web Browsers Using the command/response tableCommunication and Control IPL T S Series Communication and ControlIPL T S Series Communication and Control Password information Copyright informationError responses Series Communication and Control CommunicationBidirectional serial data port Ascii to Decimal Conversion Table X!*X2CY  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X3,X3!CFSeries Communication and Control X5,X5#,X2X6 TC Ethernet data portFirmware version, part number and information requests X1! Series X4, X4&   X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR  X4%SMIpmX1$ ,X1% ,X7# ,X7$  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM  X1& ,X1% CM WX1$ %2CX1% CM X1#CT  X1@CNX1@ X1# X6$ EB  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X6$,X1$  X3# CU WX3# CU Password and security settings X3# CA X5@Remap port designations WMTDirectories ECJ WCJEDF Stream files via Telnet or RS-232 ZQQQ Server Side Includes SSI CustomizationCustom Web pages Server Side Include Using a Remote SIS command Query stringCode examples Example6b Browser view of previous Html source code URL encoding Reserved charactersUnsafe characters Serial pass-through redirect modeAdvanced Serial Port Control Direct port access ports 2001 through IPL T S2Serial Bridging Hardware connectionSerial bridge configuration IPL T S4Data connections TroubleshootingPower connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories IPL T S Series Specifications, Part Numbers, Accessories Specifications, Part Numbers, AccessoriesSpecifications EMI/EMC Included parts Replacement part Number Part Numbers and AccessoriesOptional accessories Accessories Part numberAppendix B IPL T S Series Glossary GlossaryGlossary IPL T S Series Glossary Extron’s Warranty Extron USA West