Extron electronic manual Direct port access ports 2001 through, IPL T S2

Page 65

CO

M 1

CO

M 2

 

# 09301

2052

UID

 

LAN

 

POWE

R

 

 

 

12V MAX

 

.5A

 

 

TCP/IP

Network

Ethernet

Remote User

Control &

Administrator

Monitoring

Extron

IPL T S2

Ethernet Control

Interface

RS-232

RS-232

Lapt

op

DVD

 

VCR

 

Extron

Extron MediaLink or Other Controller

Projector

Figure 4-8Pass-through mode

In the figure above, a MediaLink® controller connected to the IPL T S2’s serial port 1 (COM1) is controlling a projector connected to serial port 2 (COM2).

Serial pass-through is enabled or disabled through the Com Configuration tab of a device within the Extron Global Configurator software.

Advanced users can use the pass-through SIS command as well. See the “Command/response table for Simple Instruction Set (SIS) commands”, earlier in this chapter, for detailed command descriptions.

Direct port access (ports 2001 through 2006)

Direct port access allows a direct, one-to-one connection to any of the serial ports using a TCP/IP connection. When a TCP session is initiated to port 2001 (COM1) through port 2006 (COM6), all data sent and received passes directly to and from that port without any processing. Set serial port parameters (baud rate, parity, and so on.) within the IPL T S Series unit prior to using direct access. (See “Port Settings” in chapter 3).

NThe reserved TCP port numbers (2001-2006) are default assignments. To initiate direct port access using DataViewer:

1.If necessary, set serial port parameters (baud rate, parity, and so on.) within the IPL T S unit. (See “Port Settings” in chapter 3.)

2.Launch the DataViewer software program.

3. Click the TCP/IP tab on the Communication Setup dialog box.

4.Complete the fields with the appropriate IP address and the TCP/IP port number (2001-2006), as shown below.

NA password is not required for direct port access.

IPL T S Series • Communication and Control 4-25

Image 65
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About the IPL T S Series Interface IntroductionAbout This Manual IPL T S6 FeaturesIntroduction, cont’d Two Installation Overview Installation and OperationIPL T S Series Installation and Operation Mounting the IPL T S InterfaceMounting Type Kit PN Mounting optionsRack mounting an IPL T S Series interface Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationIdentification Front panel indicatorsOperation 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Connecting the Hardware Connection and ConfigurationIPL T S Series Connection and Configuration Ethernet connectionIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Status ConfigurationSystem Settings Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four Communication and Control Using the command/response tableProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlIPL T S Series Communication and Control Copyright information Password informationError responses Bidirectional serial data port CommunicationSeries Communication and Control Ascii to Decimal Conversion TableX2%, X2, X2&, X2   X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X!*X2CY  X!*X3,X3!CFX6 TC X5,X5#,X2Series Communication and Control Ethernet data portFirmware version, part number and information requests X1! Series  X4%CR  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4& X4, X4&   X4%SM X1$ ,X1% ,X7# ,X7$ CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CMX1@  X1@CN X1#CT X1# X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X2@  X6$ EB  X6$,X1$  X3# CA Password and security settings X3# CU WX3# CU X5@WMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Server Side Includes SSI CustomizationCustom Web pages Query string Server Side Include Using a Remote SIS commandExample Code examples 6b Browser view of previous Html source code Reserved characters URL encodingUnsafe characters Serial pass-through redirect modeAdvanced Serial Port Control IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationData connections TroubleshootingPower connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories IPL T S Series Specifications, Part Numbers, Accessories Specifications, Part Numbers, AccessoriesSpecifications EMI/EMC Optional accessories Part Numbers and AccessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B IPL T S Series Glossary GlossaryGlossary IPL T S Series Glossary Extron’s Warranty Extron USA West