Extron electronic IPL T S X1! , Series, Firmware version, part number and information requests

Page 49

IPL

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

Firmware version, part number and information requests

NIn a query response, an asterisk (*) after the version number indicates the version that is currently used.

A question mark (? or ?.??) indicates that the factory default firmware is the only firmware loaded in the IPL T S unit.

A carat (^) indicates the version of firmware that should be running, but, since a mode 1 reset was performed, the factory default firmware version is loaded and running instead. An exclamation point (!) indicates that the firmware is corrupted.

NResponses to commands differ depending on which, if any, verbose response mode the IPL T S device is in. See the CV command (EX2@ CV}) under IP setup commands later in this table.

Query firmware

Q or 1Q

Q or 1Q

X1! ]

 

Show the IPL T S unit’s firmware version

version

 

 

or Ver01*X1! ]

 

(X1!) to two decimal places. This query

Example:

1Q

1Q

1.01

 

yields the number of the currently running

 

 

 

or Ver01*1.01

 

version of the user-updatable firmware.

Query verbose

0Q

0Q

Sum of responses from 2Q-3Q-

Show the bootstrap, factory-installed, and

firmware version

 

 

4Q]

 

updated firmware versions.

information

 

 

or Ver00*sum of responss from

See 2Q, 3Q, and 4Q below.

 

 

 

2Q-3Q-4Q]

 

 

Example:

0Q

0Q

1.03-1.00(1.18-IPL Series

-Thu, 20 Jan 2005 09:41:47 GMT)-1.01*(1.31-IPL

 

 

 

Series -Tue, 14 Jun 2005 00:54:58 GMT)]

T S Series •

Query bootstrap

2Q

2Q

firmware version

 

 

Example:

2Q

2Q

Query factory

3Q

3Q

firmware version

 

 

X1! ]

or Ver02*X1! ]

1.03 ]

X1! (plus Web ver.-desc-UL date/time)]

or Ver03*X1! (plus Web ver.- desc-UL date/time)]

The bootstrap firmware is not user- replaceable, but you may need this information during troubleshooting.

Factory-installed firmware is different from the bootstrap firmware, but it is also not user- replaceable. This firmware was installed at the factory; it is the version the controller reverts to after a mode 1 reset (see ch. 2).

Example:

3Q

3Q

1.00(1.18-IPL Series

-Thu, 20 Jan 2005 09:41:47 GMT) ]

Query updated

4Q

4Q

firmware version

 

 

X1! (plus Web ver.-desc-UL date/time)]

or Ver04*X1! (plus Web ver.- desc-UL date/time)]

In this example the factory firmware version is 1.00 and the IP Link kernel version is 1.18 for the IPL T S unit, dated 20 January 2005.

Use this command to find out which version of the firmware, if any, was uploaded into the controller after it left the factory.

Communication and Control 4-9

Example:

4Q

4Q

1.01*(1.31-IPL Series

-Mon, 28 Feb 2005 23:16:55 GMT) ]

 

In this example the current firmware version

 

is 1.01, the IP Link kernel version is 1.31, for

 

the IPL T S device, dated 28 February, 2005.

Image 49
Contents IP Link Ethernet Control Interfaces IPL T S SeriesSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice IPL T S SeriesIi IPL T S Series IPL T S Series Quick Start QS-1 Quick Start IPL T S SeriesQS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One About This Manual IntroductionAbout the IPL T S Series Interface IPL T S6 FeaturesIntroduction, cont’d Two Installation Overview Installation and OperationIPL T S Series Installation and Operation Mounting the IPL T S InterfaceRack mounting an IPL T S Series interface Mounting optionsMounting Type Kit PN Furniture or projector mounting Installation and Operation, cont’dMounting the interface Rear Panel Features and CablingSection A-A PowerSerial Communication Ethernet/LANPin Function RS-232 RS-422 RS-485 IPL T S Series InstallationOperation Front panel indicatorsIdentification 13 IPL T S4 front panel Resetting the unitMode Activation Result Reset Mode Comparison/SummaryInstallation and Operation, cont’d Three Connecting the Hardware Connection and ConfigurationIPL T S Series Connection and Configuration Ethernet connectionIPL T S4 Setting the Internet Protocol IP AddressSetting the IP address using Global Configurator Connection and Configuration, cont’dSetting the IP address in Global Configurator Setting the IP address using embedded Web pagesInternet Protocol TCP/IP Properties dialog box Example C\arp -s 10.13.197.64 00-05-A6-00-30-5F Setting the IP address using the ARP commandClick the Download GCSW3XX.exe button Configuration using Global ConfiguratorGlobal Configurator Configuration using Embedded Web PagesWeb server Password dialog box Connecting via the Web server pagesSystem Settings ConfigurationSystem Status Port Settings 12 System Settings screenEmail Alerts PasswordsFile Management Firmware UpgradeClick the Control Software icon Configuration using DataViewer19 Communication Setup dialog box Four Communication and Control Using the command/response tableProgrammer’s Guide for Telnet and Web Browsers IPL T S Series Communication and ControlIPL T S Series Communication and Control Copyright information Password informationError responses Bidirectional serial data port Communication Series Communication and Control Ascii to Decimal Conversion TableX2%, X2, X2&, X2   X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2 X!*X2CY  X!*X3,X3!CFX6 TC X5,X5#,X2Series Communication and Control Ethernet data portSeries X1! Firmware version, part number and information requests  X4%CR  X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4& X4, X4&   X4%SM X1$ ,X1% ,X7# ,X7$ CM  X4%,X7,X4&SM WX4%%2CX7%2CX4&SMIpmX1$ ,X1% ,X7# ,X7$  X1& ,X1% CM WX1$ %2CX1% CMX1@  X1@CN X1#CT X1# X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X2@  X6$ EB  X6$,X1$  X3# CA Password and security settings X3# CU WX3# CU X5@WMT Remap port designationsECJ WCJ DirectoriesStream files via Telnet or RS-232 EDF ZQQQ Custom Web pages CustomizationServer Side Includes SSI Query string Server Side Include Using a Remote SIS commandExample Code examples6b Browser view of previous Html source code Reserved characters URL encodingAdvanced Serial Port Control Serial pass-through redirect modeUnsafe characters IPL T S2 Direct port access ports 2001 throughHardware connection Serial BridgingIPL T S4 Serial bridge configurationPower connections TroubleshootingData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications Specifications, Part Numbers, AccessoriesIPL T S Series Specifications, Part Numbers, Accessories EMI/EMC Optional accessories Part Numbers and AccessoriesIncluded parts Replacement part Number Accessories Part numberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron USA West
Related manuals