Extron electronic IPL T S manual Serial Bridging, Hardware connection

Page 66

Communication and Control, cont’d

Figure 4-9 — DataViewer Communication Setup dialog box

5.Click OK. The DataViewer commands window opens.

6.Send serial commands directly through the selected COM port to the attached A/V device.

7.To end the direct access session, close DataViewer.

NYou can force the direct access session closed by logging on as administrator and entering "EscX!*0CD}", where X! is the selected COM port.

Serial Bridging

Serial bridging mode allows you to pass serial data between two COM ports through an Ethernet port, creating a virtual serial connection over a LAN.

To use serial bridging, two IPL T S devices (one local and one remote) must be enabled to communicate with each other, providing PC or controller access to a remote A/V device.

Hardware connection

To set up the hardware for serial bridging:

1.Verify that the serial port parameters of the two devices match, as explained under “Direct port access (ports 2001 through 2006)”.

2.For IPL T S unit 1 (the remote device), connect a serial cable to an A/V device (for example, a plasma display or projector).

3.On the same IPL T S, connect the device to your LAN.

4-26 IPL T S Series • Communication and Control

Image 66
Contents IPL T S Series IP Link Ethernet Control InterfacesConsignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschIPL T S Series FCC Class a NoticeIi IPL T S Series Quick Start IPL T S Series IPL T S Series Quick Start QS-1QS-2 IPL T S Series Quick Start Table of Contents Table of Contents, cont’d One Introduction About This ManualAbout the IPL T S Series Interface Features IPL T S6Introduction, cont’d Two IPL T S Series Installation and Operation Installation and OperationInstallation Overview Mounting the IPL T S InterfaceMounting options Rack mounting an IPL T S Series interfaceMounting Type Kit PN Installation and Operation, cont’d Furniture or projector mountingRear Panel Features and Cabling Mounting the interfacePower Section A-AEthernet/LAN Serial CommunicationIPL T S Series Installation Pin Function RS-232 RS-422 RS-485Front panel indicators OperationIdentification Resetting the unit 13 IPL T S4 front panelReset Mode Comparison/Summary Mode Activation ResultInstallation and Operation, cont’d Three IPL T S Series Connection and Configuration Connection and ConfigurationConnecting the Hardware Ethernet connectionSetting the Internet Protocol IP Address IPL T S4Connection and Configuration, cont’d Setting the IP address using Global ConfiguratorSetting the IP address using embedded Web pages Setting the IP address in Global ConfiguratorInternet Protocol TCP/IP Properties dialog box Setting the IP address using the ARP command Example C\arp -s 10.13.197.64 00-05-A6-00-30-5FConfiguration using Global Configurator Click the Download GCSW3XX.exe buttonConfiguration using Embedded Web Pages Global ConfiguratorConnecting via the Web server pages Web server Password dialog boxConfiguration System SettingsSystem Status 12 System Settings screen Port SettingsPasswords Email AlertsFirmware Upgrade File ManagementConfiguration using DataViewer Click the Control Software icon19 Communication Setup dialog box Four Programmer’s Guide for Telnet and Web Browsers Using the command/response tableCommunication and Control IPL T S Series Communication and ControlIPL T S Series Communication and Control Password information Copyright informationError responses Series Communication and Control CommunicationBidirectional serial data port Ascii to Decimal Conversion Table X!*X2CY  X!* X2%, X2, X2&, X2*CP WX! %2A X2% %2CX2 %2CX2X2%, X2, X2&, X2   X!*X3,X3!CFSeries Communication and Control X5,X5#,X2X6 TC Ethernet data portX1!  SeriesFirmware version, part number and information requests X4, X4&   X4%, X4, X4&CR WX4%%2CX4%2CX4&CR IprX4%,X4,X4&  X4%CR  X4%SMIpmX1$ ,X1% ,X7# ,X7$  X4%,X7,X4&SM WX4%%2CX7%2CX4&SM X1$ ,X1% ,X7# ,X7$ CM  X1& ,X1% CM WX1$ %2CX1% CM X1#CT  X1@CNX1@ X1# X6$ EB  X2@  X6$,X1$ EB  WX6$%2CX1$EB Bmd X6$,X1$  X6$,X1$  X3# CU WX3# CU Password and security settings X3# CA X5@Remap port designations WMTDirectories ECJ WCJEDF Stream files via Telnet or RS-232 ZQQQ Customization Custom Web pagesServer Side Includes SSI Server Side Include Using a Remote SIS command Query stringCode examples Example6b Browser view of previous Html source code URL encoding Reserved charactersSerial pass-through redirect mode Advanced Serial Port ControlUnsafe characters Direct port access ports 2001 through IPL T S2Serial Bridging Hardware connectionSerial bridge configuration IPL T S4Troubleshooting Power connectionsData connections IPL T S Series Communication and Control Communication and Control, cont’d Specifications, Part Numbers, Accessories Specifications, Part Numbers, Accessories SpecificationsIPL T S Series Specifications, Part Numbers, Accessories EMI/EMC Included parts Replacement part Number Part Numbers and AccessoriesOptional accessories Accessories Part numberAppendix B Glossary GlossaryIPL T S Series Glossary IPL T S Series Glossary Extron’s Warranty Extron USA West