Connection and Configuration, cont’d
IPL T S4
COM
| TX | RX | RTS | CTS | TX | RX | RTS | CTS |
R | 1 |
|
|
| 3 |
|
|
|
| 2 |
|
|
| 4 |
|
|
|
100
LINK ACT
1 2
Figure 3-3 — IPL T S unit’s front panel
aPower LED — A green LED lights to indicate that the interface is receiving power. Blinks four times to confirm a Mode 4 reset.
bReset button — The Reset button is recessed. Use an Extron Tweeker or similar tool to activate.
Setting the IP address using Global Configurator
The preferred method for setting a unit’s IP address is to use the Extron Global Configurator (GC) application.
If you have Global Configurator installed on a local PC, and have a GC project file open, proceed with the steps below. If you do not have Global Configurator installed, it is available as a free download from www.extron.com. The GC help file leads you through the process of creating a new GC project file, and provides an illustrated version of the procedure below.
The IPL T S unit must be:
•physically connected to the network
•at its factory default IP address
To set an IP address with a GC project file open:
1. | From the Edit menu, select Add Device. |
| The Add Device dialog box opens (see figure |
2. | Select the appropriate device type (for example, IPL T S4) in the IP Link® |
| Device |
3. | Enter the new IP address (for example, 10.14.195.40) in the Name/IP |
| Address field. |
4. | Enter a unique device name in the Display Name field. |
5. | Click the Advanced >>> button. |
| The Advanced options of the Add Device dialog are displayed, and the |
| “Advanced >>>” button name changes to “Basic <<<”. |
6. | Enable the Auto Configure IP Address check box. |
7. | Enter the unit’s MAC address in the MAC Address field. The first six digits |
| |
| only need to enter the final six digits. Dashes between digits are |
8. | Click the Set button. The Auto Configure Successful dialog box opens. |
9. | Click OK. |