Extron electronic ISM 482 manual Front Panel Operations, LCD Display, Menu Control Buttons, Power

Page 21

LCD Display

GStatus display — The 20-column by 4-line LCD displays configuration menus and status information (see “Front Panel Operations,” below, for details).

Menu Control Buttons

HMenu button — The Menu button enters and moves through the main menu system in the ISM (see “Front Panel Operations,” below, for details).

Next button — The Next button steps through the submenus in the ISM menu system (see “Front Panel Operations,” below, for details).

Adjustment Knobs

IAdjust (horizontal) and Adjust (vertical) knobs — The Adjust and Adjust knobs change settings when used in conjunction with the picture adjustment buttons or the menu system. Rotate these knobs to change picture settings when one of the picture adjustment buttons is selected. In the menu system, rotate these knobs to scroll through the selection options and make adjustments.

Front Panel Operations

Power

Power

on

The following paragraphs detail the power-up process and then describe the menu system, the picture adjustments, and selection of executive mode.

Power is automatically applied when the power cord is connected to an AC source. When AC power is applied, the switcher performs a self-test that blinks all of the front panel LEDs and then lights only the LEDs for the previously selected output and the tied input. The self-test also displays the model name, part number, and the firmware version in the LCD display. After approximately 2 seconds, the LCD reverts to its default display cycle, alternating between two displays: one showing the inputs selected for outputs 1 and output 2, and the other showing the selected output rates (see figure 16). An error-free power up self-test sequence leaves all of the LEDs off, with the exception of the selected output’s and input’s LEDs, off and the LCD cycling through the default displays.

Default Display Cycle

Extron Electronics

 

Extron Electronics

 

Out #1 In # 1

RGB

Output Rate

ISM 482

 

ISM 482

 

0.00 kHz 0.00Hz

#1 1280 x 1024 @ 60

Integration

2

60-425-01

2

Out #2 In # 3 S-Video

2

Scaling Matrix

sec.

Version x.xx

sec.

0.00 kHz 0.00Hz

sec. #2 1280 x 1024 @ 60

 

 

 

 

 

 

2

 

 

 

 

 

 

sec.

Figure 16. LCD Power Up and Default Display Cycle

The selected inputs for output 1 and output 2, the picture adjustments, and other current settings are saved in nonvolatile memory. When power is applied, the latest configuration is retrieved.

NOTE: On figure 16 and all other flowcharts in this section, solid lines indicate screen changes initiated by the operator. Dashed lines indicate screen changes that are the result of a timeout function.

ISM 482 Integrated Scaling Matrix Switcher • Operation

15

Image 21
Contents No Photo Available yet ISMSafety Instructions Specifications Availability Conventions Used in this Guide FCC Class a NoticeNotifications  X! *X1@* X1%* X1** X1 CE Software CommandsContents Html Operation Switcher SoftwareEthernet Connection Reference InformationAbout the Switcher IntroductionAbout This Guide ISM Inputs FeaturesISM 482 Integrated Scaling Matrix Switcher Introduction Mounting the Switcher InstallationTabletop Placement Rack MountingInput Connections Cabling and Rear Panel ViewsConnections for Various Input Video Formats BNC Output Connections for Rgbhv and Rgbs Video Standard Output ConnectionsOptional Output Connection Cabling and RJ-45 connector wiringEthernet Connection Choosing a network cableWiring the network cable ConfigurationRS-232 Connection Pin RS-232 FunctionOperation Front Panel Controls and IndicatorsOutput Buttons and LEDs Video/Audio Selection Button and LEDsInput Buttons, LEDs, and Label Window Recalling a user presetFront panel input label window Selecting an inputPicture Adjustment Buttons Black/Mute Button and LEDsAuto imaging an input Power Adjustment KnobsFront Panel Operations LCD DisplayExtron Electronics ISM 60-425-01 Version Menu System OverviewInput Configuration submenu Video & Audio Configuration menuOutput Resolution submenu Output Configuration menuSync Type and Polarity submenu 000 Advanced Configuration MenuRGB Delay submenu Blue-Only Mode and Edge Smoothing submenuTest Pattern submenu Blanking submenuPixel Phase submenu Enhanced Mode submenuPAL Film Mode submenu Reset submenuSave Preset submenu User Presets menuExit menu Erase Preset submenuPicture Adjustments Flowchart Picture AdjustmentsFront Panel Security Lockout Flowchart Front Panel Security Lockout Executive ModeIP Information IP Information FlowchartOptimizing the Video Troubleshooting Setting up a DVD sourceOptimizing the Audio General Checks Specific ProblemsRS-232 Link Programming GuideEthernet Link Default Address= Hdtv SymbolsPower-up Switcher-Initiated MessagesTies Creation Input and Output Video Type@BrtX1 PAL Film Mode RGB DelayAutomated Adjustments Test PatternHost-to-Switcher Instructions Switcher Error ResponsesUsing the Command and Response Table Command and Response Table for SIS Commands Brightness TintContrast Horizontal sizeCommand and Response Table for SIS Commands Detail filter S-video and composite video inputs User presetsAuto Memories FreezeVerbose mode Front panel security lockout Executive modeSet audio gain and attenuation Audio muteInformation requests ResetsCommand and Response Table for IP SIS Commands Symbol definitionsCommand and response table Scaler output settings RGB delayEnhanced mode PAL film modeMemory backup Switcher Software Installing the SoftwareControl Software for Windows Software Operation via Ethernet Ethernet protocol settingsIf you selected a comm port, proceed to step Using the Control ProgramWindows Control Program Window Button-Label Generator Using the Help ProgramExtron Button-Label Generator Window Using the SoftwareLoading the Startup Control Html OperationEnter Network Password Control Changing the RGB DelayCreating a Tie Blacking out the Screen and Muting the AudioExecutive Mode Using Blue-Only ModeFreezing the Output Outputting a Test PatternAdministration Fields System ConfigurationISM IP Address field ISM IP Settings FieldsISM Name field Hardware Address fieldFile Management File ManagementO Configuration Input ConfigurationOutput Resolution, Rate, Sync Format, and Polarity Output resolution Output rateOutput format Polarity Drop Box Output polarityOpening and Closing the Switcher Maintenance ModificationsRemoving the ISM Cover ISM Firmware Chip Locations Installing a Firmware UpgradeDVI Output Card Connector Opening and Socket J14 Installing a DVI Output CardOutput DVI Board Installation Cabling Ethernet ConnectionDetermining Default Addresses Pinging to Determine the Switcher IP AddressPinging to Determine the Web IP Address Connecting as a Telnet Client Telnet TipsOpen Local echo Escape character and Esc keySet carriage return-line feed CloseReference Information Optional AccessoriesPart Numbers Included PartsAssorted connectors Cables and ConnectorsButton Labels Bulk cablePage USA, Canada, South America Central America Japan Extron Warranty