Ethernet Link
The rear panel Ethernet connector on the switcher can be connected to the an Ethernet LAN or WAN (see figure 27). This connection makes SIS control of the switcher possible using a computer connected to the same LAN or WAN.
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
Crossover Cable
| End 1 | End 2 |
Pin | Wire color | Wire color |
|
|
|
1 | ||
2 | Green | Orange |
3 | ||
4 | Blue | Blue |
5 | ||
6 | Orange | Green |
7 | ||
8 | Brown | Brown |
|
|
|
| T568A | T568B |
A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crossover" cable.
Pin | End 1 | End 2 |
Wire color | Wire color | |
|
|
|
1 | ||
2 | Orange | Orange |
3 | ||
4 | Blue | Blue |
5 | ||
6 | Green | Green |
7 | ||
8 | Brown | Brown |
|
|
|
T568BT568B
A cable that is wired the same at both ends is called a
Figure 27. RJ-45 Connector Pinout Tables
Ethernet Connection
The cable can be terminated as either a patch cable or a crossover cable (see figure 27) and must be properly terminated for your application:
•Patch (straight) cable — Connection of the ISM to an Ethernet hub, router, or switcher that also hosts a controlling computer
•Crossover cable — Direct connection between the ISM and a computer
Default Address
To access the switcher via the Ethernet port, you need the switcher’s IP address. If the address has been changed to an address comprised of words and characters, the actual numeric IP address can be determined using the front panel (see IP Information on page 27) or the Ping utility (see Pinging to Determine the Switcher IP Address or Ping to determine the Web IP address on page 70 for more details). If the address has not been changed, the