5.0 Update storage and firmware
You can update the ATTO FastStream VT 5300 at any time. Refer to www.attotech.com for complete information.
Several methods are available to update the ATTO FastStream firmware and to
before using any of these procedures to prevent data loss.
Remove stale VTL configuration data
Initializing the attached storage may be used to remove stale VTL configuration data from a drive that is known to be in good health.
This operation erases all information stored on your drive; back up data before selecting Commit.
CAUTION
Data is erased during this process. Back up your data before selecting Commit. These operations have a negative impact on the performance of normal operations; all activity should be stopped.
1If you are not already in the FastStream GUI, type the IP address of your appliance, as found in Use the FastStream VT 5300 GUI on page 23, in a standard browser, click Enter Here and type in your username and password.
2Click the Diagnostics button
3Click the Initialize and Verify button or the Initialize Only button.
4Click Next
5Click on the drives you wish to test; the drives are highlighted.
6Select Initialize and Verify
7Click Commit
8A warning message displays; choose yes to continue.
9The Drive Performance and Health screen appears
10The Time Remaining box tells you how much time remains until the process is complete. The representation of each drive in the Drives box shows the percentage completed.
Update firmware
The ATTO FastStream VT 5300 has several processors which control the flow of data. The firmware to control these processors can be upgraded in the field using the PUT command from an FTP connection or the zModem utility over an
Preliminary steps
1The ATTO FastStream VT 5300 firmware is distributed as a compressed .zip file. Uncompress the .zip file into an image file (.ima). Note the filename. The .zip file can be uncompressed using any utility that supports the zip format.
CAUTION
Ensure that all I/O to the ATTO FastStream VT 5300 has stopped.
During this procedure, do not interrupt the flash process. Do not power down the host or the ATTO FastStream VT 5300 until the display returns the Ready prompt.
Interrupting the flash process makes your ATTO FastStream VT 5300 inoperable and you will have to return it to ATTO for repair.
2Decide whether to use FTP over Ethernet or a terminal program using the
21