ATTO Technology FastStream VT RGDisplay, RGHaltConversion, RGHaltRebuild, RGMemberAdd, RGRebuild

Page 45

RGDisplay

Displays status information for a single RAID Group, or if All is used, all available RAID groups.

RGDisplay [GroupName All ]

RGHaltConversion

Stops the conversion on the specified existing RAID Group.

RGHaltConversion [GroupName]

RGHaltRebuild

Stops the rebuild(s) on the specified existing RAID Group. MemberIndex specifies the RAID member whose rebuild is stopped. If no MemberIndex is specified, all rebuilds on that RAID Group are stopped.

RGHaltRebuild [GroupName] <MemberIndex>

RGMemberAdd

Adds an available block device to a NEW RAID Group. This command fails if the specified RAID Group does not exist, if the specified RAID Group is not in the NEW state, or if the specified block device index does not represent an available device. The RAID Group cannot have been saved using the RGCommit command.

RGMemberAdd [GroupName] [BlockDevID]

RGMemberRemove

Removes a RAID member from a NEW RAID Group. This command fails if the specified RAID Group does not exist, if the specified RAID Group is not in the NEW state, or if the specified block device index does not represent an available device. The RAID Group cannot have been saved using the RGCommit command.

RGMemberRemove [GroupName] [BlockDevID]

RGRebuild

Starts rebuilding the specified existing RAID Group. Optional parameter MemberIndex specifies the member to rebuild. If no member is specified, all degraded members are rebuilt. Optional parameter BlockDeviceID allows an available block device to be substituted for the RAID Member currently assigned to the MemberIndex.

RGRebuild [GroupName] <MemberIndex> <BlockDeviceID>

RGResumeConversion

Continues the stopped conversion on the specified existing RAID Group.

RGResumeConversion [GroupName]

RGResumeRebuild

Continues the rebuild(s) on the specified existing RAID Group. MemberIndex specifies the RAID member whose stopped rebuild is continued. If no MemberIndex is specified, all stopped rebuilds on that RAID Group are continued.

RGResumeRebuild [GroupName] <MemberIndex>

RGSpanDepth

Sets the span depth on the specified existing RAID Group. The RAID Group must be RAID Level 0, RAID Level 1, RAID Level 5, or RAID Level 10.

Default: 1

set RGSpanDepth [GroupName] [SpanDepth [1-32]] get RGSpanDepth [GroupName]

RGSpeedRead

Performs look-ahead during reads from RAID Group member disks for ALL or the specified RAID Group. This command fails if the RAID Group does not exist. GroupName is the ASCII name of the RAID Group for which look-ahead reads are performed.

Default: disabled

set RGSpeedRead [GroupName all] [enabled disabled] get RGSpeedRead [GroupName all]

RGWaitTimeout

Specifies the maximum time in seconds that the system waits to discover previously-configured RAID groups attached to the drive. The timeout is used during system boot time and when the BlockDevScan command is issued.

Default: 5

set RGWaitTimeout [1-3600] get RGWaitTimeout

RMState

Sets the member state on the specified existing RAID Group member(s). RAID Group may not be in the NEW state. Optional parameter MemberIndex specifies the RAID Member whose status is to be set. If no MemberIndex is specified, the status of all members of the specified RAID Group is set.

Note

Members undergoing rebuild are not changed. Rebuilds on these members must first be stopped.

set RMState [GroupName] <MemberIndex> [Online Degraded Unavailable Faulted]

get RMStatus

xvi Appendix

Image 45
Contents FastStream VT Page Page Contents Appendix E Warranty, contact information Xxi Update storage and firmwareModify storage Interface optionsVirtual Tape features Hardware featuresBackup and restore features Management and control featuresGb FC Switch GbE Switch Ethernet Fibre ChannelGbE network Physical attributes Installation Unpack the packing box verify contents InstallationInstall the FastStream Install Windows driversClick on Launch Browser Begin initial configurationConfigure Virtual Tape Use custom initial setup Use quick initial configurationClick on the Add/Remove Hot Spares button Use Hot Spare devicesEnable/Disable Write Protection page appears Click in the Enable/Disable Write Protection buttonSecure data through Write Protection Move Virtual Tape CartridgesCustomize the username, password Change system configurationsOptional changes to system parameters Advanced CLI Changes to other parameters may be made using the AdvancedMonitor VTL Monitor storage and diagnose configurationsConfiguration Display Health and Status MonitorPhone home E-mail messages Click the Set up Error Notification button ConfigurationMeasure drive performance Verify storage Scan drive surfacesClick the Initialize and Verify button Select Verify OnlyModify storage Initialize and verify drivesAdd drives to a RAID Group Add or remove Hot Spares Rebuild RAID GroupsSelect Rebuild RAID Groups Select the Add/Remove Hot Spares buttonAdd a VTL from another FastStream VTL Delete a VTLClick in the Delete Virtual Tape Library button Move Virtual Tape Cartridges Remove stale VTL configuration data Update storage and firmwareUpdate firmware Preliminary stepsUse the RS-232 serial link Use FTP over EthernetSend File Click Send FileInterface options Use the serial portType FastStream VT 5300 in the New Connection dialog box Enter Use TelnetAppendix a Cabling Scsi cablingCable types Cable length Fibre Channel connectionsJbod Just a Bunch of Disks Appendix B Designing RAID groupsRAID Level DiskIv Appendix Appendix C CLI provides an ASCII-based interface Symbol IndicatesMp1 CLI error messagesCLI summary Command Default ExampleViii Appendix Sntp CLI command explanations DHCPFixedDelay DefaultInterleaveDriveTestConfig DumpConfigEmailNotifyAddress EmailPasswordEmailServerAddress EmailUsernameFCDataRate FCPortErrorsFCHard FCHardAddressIPGateway PasswordIPSubnetMask IsReservedResetFCPortErrors RAIDCommandTimeoutRestoreConfiguration RGCancelAddStorageRGDisplay RGWaitTimeoutRGHaltConversion RGHaltRebuildSCSIPortReset SaveConfigurationSCSIPortResetOnStartup RMStatusSerialPortEcho SerialPortBaudRateSNTPServer TailEventLogFurther results of FCC Testing Appendix D Standards and compliancesThis equipment generates, uses, and can radiate radio Declaration of Conformity European StandardsAppendix E Warranty, contact information Manufacturer limited warrantyContact Atto Technology, Inc Xxii Appendix