RMStatus
Displays the status of all RAID Members within the specified RAID Group or a specific RAID member (if specified) within the specified RAID Group. This command fails if the specified RAID Group does not exist or a specified member index within the RAID Group does not exist.
RMStatus [GroupName] <MemberIndex>
Route
Assigns a SCSI LUN protocol address to a target. Use the Delete identifier to remove the map. In verbose mode, overwriting a map requires secondary confirmation of the action.
Route FC [lun] [ [RAID [GroupName] Delete ]
RouteDisplay
Displays a list of Fibre Channel to SCSI address mappings on the FastStream.
RouteDisplay FC <fp> <fl>
SaveConfiguration
Issued with the restart option, cycles unit power after saving configuration changes. The norestart option saves changes without restarting.
Note
Certain modifications require a system restart.
SaveConfiguration <Restart NoRestart>
SCSIInitID
Specifies or reports the SCSI initiator ID on the specified SCSI port as found in NVRAM. All maps coinciding with the
Default: 7
set SCSIInitID [sb
SCSIPortBusSpeed
Controls the transfer rate at which the unit attempts to negotiate with its SCSI devices.
Default: ultra320
set SCSIPortBusSpeed [sb] [fast ultra ultra2 ultra160 ultra320]
get SCSIPortBusSpeed [sb]
SCSIPortList
Returns a list of available SCSI ports and their current status. Valid status values are OK and Failed
SCSIPortList
xvii
SCSIPortReset
Resets the specified SCSI bus.
SCSIPortReset [sb]
SCSIPortResetOnStartup
Specifies if the SCSI port should be reset on power-up.
Default: enabled
set SCSIPortResetOnStartup [sb [enabled disabled] ]
Requires a SaveConfiguration command get SCSIPortResetOnStartup [sb]
SCSIPortSyncTransfer
Specifies whether synchronous SCSI transfers should be negotiated with devices on the specified SCSI port.
Default: enabled
set SCSIPortSyncTransfer [[sb [enabled disabled] ]
Requires a SaveConfiguration command
get SCSIPortSyncTransfer [sb]
SCSIPortTermination
Configures/reports the SCSI internal termination of the SCSI port identified on the FastStream.
Default: enabled
set SCSIPortTermination [sb] [enabled disabled] Requires a SaveConfiguration command
get SCSIPortTermination [sb]
SCSIPortWideTransfer
Specifies whether wide SCSI transfers should be negotiated. Enabled allows wide transfer negotiation
Default: enabled
set SCSIPortWideTransfer [sb [enabled disabled ]] Requires a SaveConfiguration command
get SCSIPortWideTransfer
SCSITargetLUNs
Sets the maximum number of SCSI LUNs per target the FastStream tries to query during a SCSI bus scan.
Default: 8
set SCSITargetLUNs [sb] [8 64] Requires a SaveConfiguration command get SCSITargetLUNs
SCSITargets
Returns a list of SCSI devices operational on the referenced SCSI port with SCSI target number, SCSI LUN number, device type, vendor ID, product ID, revision and serial number.
SCSITargets [sb]
SerialNumber
Reports the FastStream serial number which is unique for each FastStream. The serial number tracks the board throughout its life and should not be changed.
get SerialNumber
ATTO Technology Inc. FastStream VT 5300 Installation and Operation Manual