Schneider Electric XPSMF2DO801 manual Introduction, Representation, Front View, Module

Page 10

Overview

Introduction

XPSMF2DO801 XPSMF2DO801 is a safety remote output module which works with the XPSMF

Safety Remote Safety PLC range and does not contain a user program. It is designed to monitor

Output Module safety functions up to safety Category 4 according to EN 954-1 and SIL 3 according to IEC 61508 and is used to expand a Safety PLC. XPSMF2DO801 is a compact safety remote output module in a metal housing with 8 programmable relay contact outputs.

The safety remote output module is a highly visible product thanks to its red color housing. The product’s overall ingress protection rating is IP 20. The XPSMF2DO801 is an extremely versatile product and can be used in all areas of a factory floor. In areas where conditions are harsh, explosive or generally dangerous, extra protection in the form of enclosures is available to optimize the product’s performance, prolong its life, and improved safety within each factory environment. The XPSMF2DO801 is a very powerful safety remote output module and is very easy to program and install.

Representation

Front View

The following image shows the front view of the XPSMF2DO801 remote output

 

module:

L- L- L+ L+

1 2

3 4

5 6

7 8

L-

L- L+ L+

 

 

 

 

DO1

DO2

DO3

DO4

24V DC

 

RUN

HIMatrix F28 01

FAULT

ERROR

by HIMA

PROG

DO

FORCE

 

OSL

 

BL

 

DO5

DO6

DO7

DO8

HIMA

 

 

 

1

10/100BaseT

10/100BaseT

2

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

10

33003405 07/2007

Image 10
Contents XPSMF2DO801 Remote Output Module Hardware Manual 07/2007Page Table of Contents Appendices At a GlanceProcedure Safety InformationImportant Information Safety Information About the Book At a Glance33003405 07/2007 Overview Whats in this Chapter? Overview XPSMF2DO801Topic Front View IntroductionRepresentation ModuleDimensions Dimensions Remote output moduleSide View Introduction InstallationProcedure Step ActionHIMatrix 100 Compact device Cable duct Spacer = H 40 mm / 1.57 Installation with spacersLength of the required spacer is calculated as follows = length of the spacer = height of the cable ductHIMatrix F31 Heat Case installation Calculation of a m2 1m2=10.76ft2 Convection HousingInternal Variable DescriptionTemperature State/Operating Temperature range Temperature stateOverview Application and Function Overview XPSMF2DO801 safety remote output moduleInitial Operation StageApplication Function Terminal No Designation Function relay output Application and Function Following will occur CableDisconnection SystemVoltage level Reaction of the controller Power Supply InterruptionLarge System Reconfiguration StepShort-Circuit Characteristics Output Channels SHORT-CIRCUIT ConditionModules Offline Proof Test Execution Periodic Proof TestingOffline Proof-Test Offline ProofWhats in this Equipment DescriptionOutput module Chapter?XPSMF2DO801 safety remote output module Housing ElementsElements of the front panel Top View Following image shows the elements of the top panel Back Panel Following image shows elements of the back panel Housing, about 40...50 mm 1.57...1.97 in. from the left rim Reset ButtonUsing Reset ButtonCommunication via switches Overview Safety-Related CommunicationCommunication HIMatrix F3AIO Following scheme shows a SafeEthernet networking exampleNumber Following is a Ethernet cable connection diagramConnector pairs and cable distances Maximum cable distanceEquipment Description LEDs Following table describes behaviors of the LEDs LED DescriptionColor Status Meaning LED Interface WiringEthernet Wiring ElementsClass D capacity are required RJ45 ConnectorSwitches RecommendedDescription IP Addressing and System IDBit numbers e.g SafeEthernet 33003405 07/2007 Ethernet OperationParameters InterfacesUDP ports and usage Connections for SafeEthernet/ Networking ExamplesUsed Network Ports for Ethernet Communication TCP ports and usageOSI model For the next higher level and relies on the next lower levelFollowing table describes the seven OSI layers bottom-top Number Layer Data DescriptionClimatic Operating ConditionsConditions EMC Conditions MechanicalFollowing tables Equipment Description Power Supply Connectors Technical CharacteristicsMechanical Data Power Supply Connectors Signal Line ConnectorsStripping Length and Torque Relay Outputs Supply voltageList of Additional Additional ItemsItems Equipment Description Equipment Description Appendix? AppendicesAppendix contains the following chapters Chapter Chapter NameAppendices Connection Diagrams, Examples Application, and Error Codes Error Codes System signal MeaningBrief description of the functional devices Elements of the network Wiring ExamplesSafeEthernet Protocol Ethernet Wiring Example NetworkingBrief description of the functional devices Element Modbus serialFor setting the communication parameters proceed as follows Configuration of Ethernet InterfacesCommunication Settings Flow-Control Mode list, select AutonegParameters of a port configuration Konfiguration/Abl-Mode/HIMatrix F35/OMFollowing table contains the parameter descriptions Parameter DescriptionBrief description of the functional devices Glossary Field bus Functional block diagramFault tolerance time See FTTProtective extra low voltage Object linking and embeddingOSI Model Open system interconnection model Programmable electronic systemSafety integrity level according to IEC Safety extra low voltageSequential function chart System-rack-slotIndex Index