Schneider Electric
manual
XPSMF2DO801 Remote Output Module Hardware Manual, 07/2007
Technical Characteristics
Install
Error messages
Functional block diagram
Wiring
Dimension
Large System Reconfiguration
Reset Button
RJ45 Connector
Procedure
Page 1
XPSMF2DO801 Remote
Output Module
Hardware Manual
07/2007
33003405.01
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
07/2007
XPSMF2DO801 Remote Output Module Hardware Manual
Page
Table of Contents
At a Glance
Appendices
Procedure
Safety Information
Important Information
Safety Information
At a Glance
About the Book
33003405 07/2007
Overview Whats in this Chapter?
Overview XPSMF2DO801
Topic
Representation
Introduction
Front View
Module
Dimensions Remote output module
Dimensions
Side View
Procedure
Installation
Introduction
Step Action
HIMatrix
100 Compact device Cable duct Spacer
Length of the required spacer is calculated as follows
Installation with spacers
= H 40 mm / 1.57
= length of the spacer = height of the cable duct
HIMatrix F31
Heat
Case installation Calculation of a m2 1m2=10.76ft2
Internal
Housing
Convection
Variable Description
Temperature range Temperature state
Temperature State/Operating
Overview
Application and Function
Initial Operation
XPSMF2DO801 safety remote output module
Overview
Stage
Application
Function
Terminal No Designation Function relay output
Application and Function
Disconnection
Cable
Following will occur
System
Large System Reconfiguration
Power Supply Interruption
Voltage level Reaction of the controller
Step
SHORT-CIRCUIT Condition
Short-Circuit Characteristics Output Channels
Modules
Offline Proof Test
Offline Proof-Test
Periodic Proof Testing
Execution
Offline Proof
Output module
Equipment Description
Whats in this
Chapter?
XPSMF2DO801 safety remote output module
Housing Elements
Elements of the front panel
Top View Following image shows the elements of the top panel
Back Panel Following image shows elements of the back panel
Using Reset
Reset Button
Housing, about 40...50 mm 1.57...1.97 in. from the left rim
Button
Communication via switches
Overview Safety-Related Communication
Communication
Following scheme shows a SafeEthernet networking example
HIMatrix F3AIO
Connector pairs and cable distances
Following is a Ethernet cable connection diagram
Number
Maximum cable distance
Equipment Description
LEDs
Following table describes behaviors of the LEDs
LED Description
Color Status Meaning
LED
Ethernet Wiring
Wiring
Interface
Elements
Switches
RJ45 Connector
Class D capacity are required
Recommended
Description
IP Addressing and System ID
Bit numbers e.g
SafeEthernet
33003405 07/2007
Parameters
Operation
Ethernet
Interfaces
Used Network Ports for Ethernet Communication
Connections for SafeEthernet/ Networking Examples
UDP ports and usage
TCP ports and usage
For the next higher level and relies on the next lower level
OSI model
Number Layer Data Description
Following table describes the seven OSI layers bottom-top
Climatic
Operating Conditions
Conditions
EMC Conditions
Mechanical
Following tables
Equipment Description
Mechanical Data Power Supply Connectors
Technical Characteristics
Power Supply Connectors
Signal Line Connectors
Stripping Length and Torque
Supply voltage
Relay Outputs
List of Additional
Additional Items
Items
Equipment Description
Equipment Description
Appendix contains the following chapters
Appendices
Appendix?
Chapter Chapter Name
Appendices
Connection Diagrams, Examples Application, and Error Codes
System signal Meaning
Error Codes
Brief description of the functional devices
SafeEthernet Protocol Ethernet Wiring Example
Wiring Examples
Elements of the network
Networking
Brief description of the functional devices
Modbus serial
Element
Communication Settings
Configuration of Ethernet Interfaces
For setting the communication parameters proceed as follows
Flow-Control Mode list, select Autoneg
Konfiguration/Abl-Mode/HIMatrix F35/OM
Parameters of a port configuration
Parameter Description
Following table contains the parameter descriptions
Brief description of the functional devices
Glossary
Fault tolerance time
Functional block diagram
Field bus
See FTT
OSI Model Open system interconnection model
Object linking and embedding
Protective extra low voltage
Programmable electronic system
Sequential function chart
Safety extra low voltage
Safety integrity level according to IEC
System-rack-slot
Index
Index
Related pages
What maintenance tips are recommended for the
Zephyr CBE-1000 blower
?
Top
Page
Image
Contents