Ambient Temperature Conditions

Careful consideration of things such as image size, ambient light level, projector placement and type of screen to use are critical to the optimum use of the projection system.

Operation temperature :

Max. ambient temperature : 40 °C (104°F)

Min. ambient temperature : 0 °C (32°F).

The projector will not operate if ambient air temperature falls outside this range (0°C- 40°C) (32°F-104°F). Storage temperature : -35 °C to + 65 °C (-25.6°F to 149°F)

Humidity Conditions

Storage : 0 - 98% RH Non-condensing

Operation : 0 - 95% RH Non-condensing

Environment

Do not install the projection system in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.

Environment condition check

Warning: Harmful Environmental Contamination Precaution

A projector must always be mounted in a manner which ensures the free flow of clean air into the projectors ventilation inlets. For installations in environments where the projector is subject to airborne contaminants such as that produced by smoke machines or similar (these deposit a thin layer of greasy residue upon the projectors internal optics and imaging electronic surfaces, degrading performance), then it is highly advisable and desirable to have this contamination removed prior to it reaching the projectors clean air supply. Devices or structures to extract or shield contaminated air well away from the projector are a prerequisite, if this is not a feasible solution then measures to relocate the projector to a clean air environment should be considered.

Only ever use the manufactures recommended cleaning kit which has been specifically designed for cleaning optical parts, never use industrial strength cleaners on a projectors optics as these will degrade optical coatings and damage sensitive optoelectronic components. Failure to take suitable precautions to protect the projector from the effects of persistant and prolonged air contaminants will culminate in extensive and irreversible ingrained optical damage. At this stage cleaning of the internal optical units will be non- effective and impracticable. Damage of this nature is under no circumstances covered under the manufactures warranty and may deem the warranty null and void. In such a case the client shall be held solely responsible for all costs incurred during any repair. It is the clients responsibility to ensure at all times that the projector is protected from the harmful effects of hostile airborne particles in the environment of the projector. The manufacture reserves the right to refuse repair if a projector has been subject to wantful neglect, abandon or improper use.

Special care for Laser beams

Special care should be used when DLP projectors are used in the same room as performant laser equipment. Direct or indirect hitting of a laser beam on to the lens can severely damage the Digital Mirror Devices (TM) in which case there is a loss of warranty

Which screen type?

There are two major categories of screens used for projection equipment. Those used for front projected images and those for rear projection applications.

Screens are rated by how much light they reflect (or transmit in the case of rear projection systems) given a determined amount of light projected toward them. The ‘GAIN’ of a screen is the term used. Front and rear screens are both rated in terms of gain. The gain of screens range from a white matte screen with a gain of 1 (x1) to a brushed aluminized screen with a gain of 10 (x10) or more. The choice between higher and lower gain screens is largely a matter of personal preference and another consideration called the Viewing angle.

In considering the type of screen to choose, determine where the viewers will be located and go for the highest gain screen possible. A high gain screen will provide a brighter picture but reduce the viewing angle.

R5976336 BARCOSLM R6 Executive 06092001

 

3-1

 

Image 13
Contents SLM R6 Barco Projection SystemsBarco n.v./Projection Systems Table of Contents Getting Started Random Access Adjustment Mode Installation Mode Standard Source SET UP Files Index R5976336 Barcoslm R6 Executive To prevent battery explosion Safety Instruction Related to SLM ProjectorsTo prevent personel injury To prevent projector damageDefinitions Extra safety manualPackaging and Dimensions Dimensions Installation Guidelines Positioning the Projector Which configuration can be usedInstallation Guidelines Re-adjusting the lamp position in the lamp casing Safety Area around the ProjectorAvailable lenses Which Lens has to be selectedLens formulas to calculate the projector distance Installing the Projection Lens How is the battery delivered ? Cleaning the lensHow to install ? Switching on AC Power mains cord connectionConnections FusesSwitching Off Switching to Stand-byLamp Run Time Indication Lamp Runtime WarningInput facilities, RCVDS05 or VS05 connected Input facilitiesInput module insertion into the projector Pin assignment for the DVI connector Which signals can be connected to slot 1 & 2 ?How to select input Slot 1 or Fixed Slot slot 1Adjustment Mode How to change the input slot settingInstallation Input SlotsWhat can be connected to this input ? How to select the Digital inputConnections HD SDI Digital Input slot 3 Connecting a Rcvds 05 to the projector Set up of the Baud Rate for Communication with a ComputerConnecting a VS05 to the projector Connecting an IR Remote Receiver to the projectorConnections Functionality Getting StartedRCU TerminologyLamp Run Time Warning Error Temperature error DMDService Quick Language ChangeLens Adjustment ZOOM/FOCUS Quick Lens AdjustmentPointing to the reflective screen Quick On Screen Color changeOSD Color Highlighted Item Hardwired to the XLR Input Hardwired Remote InputSet up an Individual Projector Address Why a projector address ?How to control the projector or projectors ? Before using the RCUDisplay the Projector Address on the Screen How to Program an Address into the RCU ?Input Selection PictureContolsStand-by key Pause keyPasswordProtection Start UP of the Adjustment ModeEntering the Password Start upRemark Setting Up the personalised PasswordsMenus on Local LCD Display Overview Flowchart Random Access Adjustment ModeStarting up Start up the File Service Connecting a new SourcePossible File Manipulations File AnnotationStart up the Load File How to load a file ?Image is not perfect ? Load FileWhich items can be adjusted ? How to start up the Edit menu ?How to change the settings ? What can be done with the Edit File menu ?Edit File Options How to find the correct values for the displayed item?Rename File Confirm Edit FileCopy File How to change the characters ?File Load File SortDelete File Confirm Delete FileHow to change the CTI setting ? What is CTI ?Picture Tuning Adjusting the Color Temperature Available color temperatureWhat can be adjusted ? Custom BalanceWhat can be done ? How to change the Gamma Value ?How can it be selected ? PurposeTo change the noise reduction value Why adjusting the input balance ?Noise Reduction Input BalanceWhich geometry adjustments are possible ? How to adjust the input balance for YUV input signals?How can an adjustment be adjusted ? To start up the Geometry functionsTo start up the shift action To start up the size adjustmentAdjusting the blanking Available Blanking AdjustmentBlanking What can be done? Setting Up the Aspect RatioPossible results for the fixed input slots 1 To view or to change the input configurationWhat can be installed ? What if a switcher is connected to the projector ?Defining the Output module of the RCVDS05 Defining the Infrared Communication protocol How to start up ?How to change this color setting ? Set up the Correct ConfigurationWhat will happen Changing the Shutdown SettingChanging the Background Color Changing the Shutdown TimeWhat can be done with these internal patterns ? How to select an internal pattern ?How to shift the image ? How to Zoom/Focus ?Zoom/Focus/Shift Options How to get an overview ?How to set up? Installation Mode Built-up of the service mode Service ModeInformation How to display the Identification screen ?Detailed description About password Types How to enable or disable the password function ?Access Control List How to change the password ?Access Control List Entering the new projector address How to change that address ?Start Up the Serial Communication menu Installing the Interface Standard Setting up the Baud rateAvailable Baud rates RS422 TerminationHow to display the lamp menu Lamp information light output switchingHow to switch the constant light output ? How to add or the change the settings ?How to get add ins ? Available settingsHow to activate an add-in ? Available Add InsWhat can be seen ? How to select diagnosis ?How to select the overview ? How to select ?I2C Diagnosis FormatterProgrammable Function Keys Confirm Quick AccessWhat can be done with these keys How can a Function Key be programmed ?10-2 R5976336 Barcoslm R6 Executive Name Resolution Fvert Fhor Fpix Ptot Pact Ltot Lact KHZ MHZ Standard Source SET UP FilesMuse Index RCU