Random Access Adjustment Mode

How to find the correct values for the displayed item?

During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automatically measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.

Caution : Do not adjust these settings on an active file, they are used to identify the input source file.

If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).

The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).

"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.

"Horizontal Period" : already filled in with the correct value when active file. (see caution above).

The "Vertical Total Lines" are already filled when an active file is selected to be edited (see caution above).

The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification of the source. If not, adjust until full image height is displayed (no missing lines)

Vertical start : number of lines between the start of the input signal and start of the image on the screen.

Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).

Read AMDS

AMDS = automatic mode detection & synchronisation

During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced mode.

When selecting Read AMDS, the system remeasures the above indicated items.

Options

EDIT FILE OPTIONS

 

 

 

Source number

 

1

 

 

 

Clamp position

 

[trailing]

 

 

Clamp delay

 

0

 

 

 

Clamp width

 

10

 

 

 

Field polarity

 

[pos]

 

 

Field select

 

[both]

 

 

([DPVerticalSOHrefreshIRUFODPSSRVLWLRQ[sync] >WUDLOLQJ@

Select with or

 

 

 

 

 

 

 

 

 

 

￿

 

￿

 

 

<ENTER> to toggle

 

 

 

or to change value

 

 

 

D

 

O

 

 

<EXIT> to return

D

 

 

Source Number : The source number of a non-active source can be changed to any other source number. This makes it possible

6\QF&ODPS

O

 

U

 

 

to create a file for future source numbers.

SXOVH

 

 

 

&ODPS

Clamp Position : Clamping determines the black level of the signal.

The clamp pulse is always related to the trailing edge of the sync pulse.

Clamp Delay : The time between the leading edge of the clamp pulse and the locked edge of the sync pulse.

 

Can be any value between 0 and 255.

Change the value by pushing the cursor key or .

 

Clamp Width : The width of the clamp pulse

 

 

 

 

 

 

ZLGWK

Change the value by pushing the cursor key or .

 

Can be any valueGJHbetweenGJH

0 and 255.

 

 

 

 

 

&ODPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GHOD\

 

 

 

 

 

 

 

R5976336 BARCOSLM R6 Executive 06092001

 

 

7-5

 

 

Image 46
Contents Barco Projection Systems SLM R6Barco n.v./Projection Systems Table of Contents Getting Started Random Access Adjustment Mode Installation Mode Standard Source SET UP Files Index R5976336 Barcoslm R6 Executive To prevent personel injury Safety Instruction Related to SLM ProjectorsTo prevent battery explosion To prevent projector damageExtra safety manual DefinitionsPackaging and Dimensions Dimensions Installation Guidelines Which configuration can be used Positioning the ProjectorInstallation Guidelines Safety Area around the Projector Re-adjusting the lamp position in the lamp casingAvailable lenses Which Lens has to be selectedLens formulas to calculate the projector distance Installing the Projection Lens How is the battery delivered ? Cleaning the lensHow to install ? Connections AC Power mains cord connectionSwitching on FusesLamp Run Time Indication Switching to Stand-bySwitching Off Lamp Runtime WarningInput facilities Input facilities, RCVDS05 or VS05 connectedInput module insertion into the projector How to select input Slot 1 or Which signals can be connected to slot 1 & 2 ?Pin assignment for the DVI connector Fixed Slot slot 1Installation How to change the input slot settingAdjustment Mode Input SlotsWhat can be connected to this input ? How to select the Digital inputConnections HD SDI Digital Input slot 3 Connecting a VS05 to the projector Set up of the Baud Rate for Communication with a ComputerConnecting a Rcvds 05 to the projector Connecting an IR Remote Receiver to the projectorConnections Getting Started FunctionalityTerminology RCULamp Run Time Warning Service Temperature error DMDError Quick Language ChangeQuick Lens Adjustment Lens Adjustment ZOOM/FOCUSPointing to the reflective screen Quick On Screen Color changeOSD Color Highlighted Item Hardwired Remote Input Hardwired to the XLR InputHow to control the projector or projectors ? Why a projector address ?Set up an Individual Projector Address Before using the RCUInput Selection How to Program an Address into the RCU ?Display the Projector Address on the Screen PictureContolsPause key Stand-by keyEntering the Password Start UP of the Adjustment ModePasswordProtection Start upRemark Setting Up the personalised PasswordsMenus on Local LCD Display Overview Flowchart Random Access Adjustment ModeStarting up Possible File Manipulations Connecting a new SourceStart up the File Service File AnnotationImage is not perfect ? How to load a file ?Start up the Load File Load FileHow to change the settings ? How to start up the Edit menu ?Which items can be adjusted ? What can be done with the Edit File menu ?How to find the correct values for the displayed item? Edit File OptionsConfirm Edit File Rename FileHow to change the characters ? Copy FileDelete File File SortFile Load Confirm Delete FileHow to change the CTI setting ? What is CTI ?Picture Tuning What can be adjusted ? Available color temperatureAdjusting the Color Temperature Custom BalanceHow can it be selected ? How to change the Gamma Value ?What can be done ? PurposeNoise Reduction Why adjusting the input balance ?To change the noise reduction value Input BalanceHow can an adjustment be adjusted ? How to adjust the input balance for YUV input signals?Which geometry adjustments are possible ? To start up the Geometry functionsTo start up the size adjustment To start up the shift actionAdjusting the blanking Available Blanking AdjustmentBlanking Setting Up the Aspect Ratio What can be done?To view or to change the input configuration Possible results for the fixed input slots 1What can be installed ? What if a switcher is connected to the projector ?Defining the Output module of the RCVDS05 How to start up ? Defining the Infrared Communication protocolSet up the Correct Configuration How to change this color setting ?Changing the Background Color Changing the Shutdown SettingWhat will happen Changing the Shutdown TimeHow to select an internal pattern ? What can be done with these internal patterns ?How to shift the image ? How to Zoom/Focus ?Zoom/Focus/Shift How to get an overview ? OptionsHow to set up? Installation Mode Service Mode Built-up of the service modeInformation How to display the Identification screen ?Detailed description How to enable or disable the password function ? About password TypesAccess Control List How to change the password ?Access Control List Entering the new projector address How to change that address ?Start Up the Serial Communication menu Available Baud rates Setting up the Baud rateInstalling the Interface Standard RS422 TerminationHow to switch the constant light output ? Lamp information light output switchingHow to display the lamp menu How to add or the change the settings ?How to activate an add-in ? Available settingsHow to get add ins ? Available Add InsHow to select diagnosis ? What can be seen ?I2C Diagnosis How to select ?How to select the overview ? FormatterWhat can be done with these keys Confirm Quick AccessProgrammable Function Keys How can a Function Key be programmed ?10-2 R5976336 Barcoslm R6 Executive Standard Source SET UP Files Name Resolution Fvert Fhor Fpix Ptot Pact Ltot Lact KHZ MHZMuse Index RCU