Barco R9002790 manual Confirm Edit File, Rename File

Page 47

Random Access Adjustment Mode

Field Polarity :

The field polarity function is used for interlaced images. Both rasters of the image could be shifted in a wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity to [neg] or [pos].

Use the ENTER key to toggle between [pos] and [neg].

Field Select : Default [both]

The field select is only used for interlaced images. One frame of an interlaced image contains two fields, an even and an odd field. The choice exists to project [both] fields on the screen or only the [even] or [odd] field. This can be useful for 3D projection. Use the ENTER key to toggle between [both], [even] and [odd].

Vertical Refresh [sync/async] : The way of updating the image information on the LCD panels.

Not available for PAL-SECAM-NTSC sources. This option will be displayed in gray.

1For sources with a vertical frequency up to 60 Hz : the vertical refresh rate is the same as the vertical frequency of the incoming source. This is a necessity to project moving images without 'motion artifacts'. For stationary images with a vertical frequency up to 60 Hz it is still possible to use asynchronous refresh. When loading Pal, Secam, NTSC-files the synchronous mode is default, for all other sources below 60 Hz asynchronous mode is default.

2For sources with a vertical frequency higher that 60 Hz : the vertical refresh is different than the vertical frequency of the incoming source. Synchronous refresh cannot be used.

Press EXIT to leave the Edit File Option menu.

A 'Confirm Edit File' menu will be displayed.

CONFIRM

EDIT FILE

Save changes to file

xga.c30?

<ENTER> to confirm

<EXIT> to return

Press ENTER to confirm and to save the new settings or EXIT to return without saving the new entered settings.

Rename a file

Start Up.

To change the name of a selected file:

1Push the cursor key or to highlight 'Rename' (menu 1).

2 Press ENTER.

The Rename selection menu will be displayed (menu 2).

3 Push the cursor key or to select a file name (menu 2). 4 Press ENTER to select.

The Rename menu will be displayed with the selected file name already filled in, in the 'From file name :' area and in the 'To file name :' area.

The first character in the 'To file name :' area is highlighted (menu 3).

FILE SERVICE

LOAD

EDIT

RENAME

COPY

DELETE

OPTIONS

Select with or

then <ENTER> <EXIT> to return.

menu1

RENAME FILE

Filename Src Resolution

-----------------------------------------------------

Video525.s01 1

675x240i

Video525.c01

1

675x240i

Video525.c02

1

675x240i

-----------------------------------------------------

Active file : Video525.c50

Select with or

then <ENTER>

<EXIT> to return.

menu2

RENAME FILE

Frome file name :

Video525.s01 To file name : demo.c10

Select with or

Reprogram with or

or numeric keys

<ENTER> to confirm

<EXIT> to return

menu3

7-6

 

R5976336 BARCOSLM R6 Executive 06092001

 

Image 47
Contents SLM R6 Barco Projection SystemsBarco n.v./Projection Systems Table of Contents Getting Started Random Access Adjustment Mode Installation Mode Standard Source SET UP Files Index R5976336 Barcoslm R6 Executive To prevent projector damage Safety Instruction Related to SLM ProjectorsTo prevent battery explosion To prevent personel injuryDefinitions Extra safety manualPackaging and Dimensions Dimensions Installation Guidelines Positioning the Projector Which configuration can be usedInstallation Guidelines Re-adjusting the lamp position in the lamp casing Safety Area around the ProjectorLens formulas to calculate the projector distance Which Lens has to be selectedAvailable lenses Installing the Projection Lens How to install ? Cleaning the lensHow is the battery delivered ? Fuses AC Power mains cord connectionSwitching on ConnectionsLamp Runtime Warning Switching to Stand-bySwitching Off Lamp Run Time IndicationInput facilities, RCVDS05 or VS05 connected Input facilitiesInput module insertion into the projector Fixed Slot slot 1 Which signals can be connected to slot 1 & 2 ?Pin assignment for the DVI connector How to select input Slot 1 orInput Slots How to change the input slot settingAdjustment Mode InstallationConnections How to select the Digital inputWhat can be connected to this input ? HD SDI Digital Input slot 3 Connecting an IR Remote Receiver to the projector Set up of the Baud Rate for Communication with a ComputerConnecting a Rcvds 05 to the projector Connecting a VS05 to the projectorConnections Functionality Getting StartedRCU TerminologyLamp Run Time Warning Quick Language Change Temperature error DMDError ServiceLens Adjustment ZOOM/FOCUS Quick Lens AdjustmentOSD Color Highlighted Item Quick On Screen Color changePointing to the reflective screen Hardwired to the XLR Input Hardwired Remote InputBefore using the RCU Why a projector address ?Set up an Individual Projector Address How to control the projector or projectors ?PictureContols How to Program an Address into the RCU ?Display the Projector Address on the Screen Input SelectionStand-by key Pause keyStart up Start UP of the Adjustment ModePasswordProtection Entering the PasswordMenus on Local LCD Display Setting Up the personalised PasswordsRemark Starting up Random Access Adjustment ModeOverview Flowchart File Annotation Connecting a new SourceStart up the File Service Possible File ManipulationsLoad File How to load a file ?Start up the Load File Image is not perfect ?What can be done with the Edit File menu ? How to start up the Edit menu ?Which items can be adjusted ? How to change the settings ?Edit File Options How to find the correct values for the displayed item?Rename File Confirm Edit FileCopy File How to change the characters ?Confirm Delete File File SortFile Load Delete FilePicture Tuning What is CTI ?How to change the CTI setting ? Custom Balance Available color temperatureAdjusting the Color Temperature What can be adjusted ?Purpose How to change the Gamma Value ?What can be done ? How can it be selected ?Input Balance Why adjusting the input balance ?To change the noise reduction value Noise ReductionTo start up the Geometry functions How to adjust the input balance for YUV input signals?Which geometry adjustments are possible ? How can an adjustment be adjusted ?To start up the shift action To start up the size adjustmentBlanking Available Blanking AdjustmentAdjusting the blanking What can be done? Setting Up the Aspect RatioPossible results for the fixed input slots 1 To view or to change the input configurationDefining the Output module of the RCVDS05 What if a switcher is connected to the projector ?What can be installed ? Defining the Infrared Communication protocol How to start up ?How to change this color setting ? Set up the Correct ConfigurationChanging the Shutdown Time Changing the Shutdown SettingWhat will happen Changing the Background ColorWhat can be done with these internal patterns ? How to select an internal pattern ?Zoom/Focus/Shift How to Zoom/Focus ?How to shift the image ? Options How to get an overview ?How to set up? Installation Mode Built-up of the service mode Service ModeDetailed description How to display the Identification screen ?Information About password Types How to enable or disable the password function ?Access Control List How to change the password ?Access Control List Start Up the Serial Communication menu How to change that address ?Entering the new projector address RS422 Termination Setting up the Baud rateInstalling the Interface Standard Available Baud ratesHow to add or the change the settings ? Lamp information light output switchingHow to display the lamp menu How to switch the constant light output ?Available Add Ins Available settingsHow to get add ins ? How to activate an add-in ?What can be seen ? How to select diagnosis ?Formatter How to select ?How to select the overview ? I2C DiagnosisHow can a Function Key be programmed ? Confirm Quick AccessProgrammable Function Keys What can be done with these keys10-2 R5976336 Barcoslm R6 Executive Name Resolution Fvert Fhor Fpix Ptot Pact Ltot Lact KHZ MHZ Standard Source SET UP FilesMuse Index RCU