Service Mode
Setting up the Baud rate
To change the baud rate, handle as follow :
1Push the cursor key or to highlight 'Baudrate' (menu 1).
The actual baud rate will be displayed.
2Press ENTER to toggle between the available baudrates. Default : 9600
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with or
then <ENTER>
<EXIT> to return.
menu1
Available Baud rates
115200/57600/38400/19200/9600/4800/1200
Installing the Interface Standard
The communication protocol for the communication between the projector and a computer can be set on RS232 or RS422. To set up the desired protocol, handle as follow :
1Push the cursor key or to highlight 'Interface Standard' (menu 1). The actual interface standard will be displayed.
2Press ENTER to toggle between RS232 and RS422. Default : RS232
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with or
then <ENTER>
<EXIT> to return.
menu1
RS422 Termination
The last projector in a line should be RS422 terminated (ON position). All others in the line should be in the OFF position. To change the termination position :
1Push the cursor key or to highlight 'RS422 Termination' (menu 1). The actual setting will be displayed.
2Press ENTER to toggle between ON and OFF. Default setting : ON
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with or
then <ENTER> <EXIT> to return.
menu1