Garmin EDP70 manual Inverter Alarms Message Condition

Page 58

INVERTER ALARMS

 

 

 

MESSAGE

CONDITION

NOT CALIBRATED

FAULT

 

 

PCB SUPPLY FAULT

FAULT

 

 

OUT OF SYNC

WARNING

 

 

DESATURATION

FAULT

 

 

OVER TEMPERATURE

FAULT

 

 

BYPASS SWITCH CLOSED

FAULT

 

 

SHUTDOWN IMMINENT

WARNING

 

 

DC VOLTAGE HIGH

FAULT

 

 

DC VOLTAGE LOW

WARNING

 

 

INVERTER NOT RUNNING

FAULT

 

 

INVERTER INHIBITED

FAULT

 

 

INVERTER BLOCKED

FAULT

 

 

INVERTER VOLTS HIGH

FAULT

 

 

INVERTER VOLTS LOW

FAULT

 

 

OVERLOAD

WARNING

 

 

STOP DUE TO OVERLOAD

FAULT

 

 

CURRENT LIMIT

WARNING

 

 

INV.ST. SWITCH FAULT

FAULT

 

 

INV.FREQ.OUT RANG. 8%

FAULT

 

 

INV. FEEDBACK FAULT

FAULT

 

 

VERIFYING INV. FREQ.

-

 

 

VERIFYING BATT. CONT.

-

 

 

INV.FREQ.OUT 1%

FAULT

 

 

page 58 --MI00/10056 rev. 8 —05/2006

Image 58
Contents EDP70 Plus 2 --MI00/10056 rev -05/2006 Electric Shock Electrical PrecautionsEmergency Procedure Injuries Caused by Contact with Corrosive LiquidsContents Maintenance and Spare Parts Figures Equipment Delivery and Storage 8 -- MI00/10056 rev -05/2006 Introduction 36kVA Standard Configuration 24kVA Standard Configuration36kVA 480V/208V Configuration RECTIFIER/INVERTER 24/36kVA Ratings Contactor 24/36kVA Ratings Safety Eye goggles Rubber gloves Rubber apron Rubber boots Storage ALL Measurements are Millimeters and Inches 18 --MI00/10056 rev -05/2006 Cable Entry Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Cable Access PlateFuse Entry40.16 ConnectionPoints 32.68BTU/H Recommended wire sizes UPS Type = 2770 - - - e 0.125 h Tk / T0 T k Uninterruptible Power System No Unauthorized Operation Connection#$# % # #% + ,+% Nest Stationary Tool AWGM10 Indentor MoveableS2 = Equipment Reserve Switch Observe Polarities and Orientations Rear FrontRAU Female U1V1W1N PE U V W N U2V2W2 N36 --MI00/10056 rev -05/2006 36 24/30/36kVA Connections QS1 QS4 QS2Terminal board compartment 40 --MI00/10056 rev -05/2006 QS1 QS2 QS3 QS4 QS5 RearSignal connections Emergency Power Off Controls Right Control Maintenance Bypass Installing the EPO SHUT-DOWNMimic Silencing Audible AlarmLiquid Crystal Display LOAD/RES Alarms No Alarms Active RECT/BATT Alarms No Alarms ActiveInverter Alarms No Alarms Active Display Page HeadingsBattery Test Weekly Selected Language EnglishPower History Down to Access Load F xx.x Hz Xxx V B xxx V C Last Mains Failure xxd xxh xxm xxs Inverter F xx.x Hz AB xxx V BC xxx V CA xxx Vdc xxx V Ib xxxx aInverter F xx.x Hz Xxx V B xxx V C xxx InverterLoad Main page Heading Alarms Message Condition Abnormal operating mode messagesSystem Alarm Overload Battery DischargingStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Power History MatrixResetting data loss manually Battery TestBattery Autonomy Test System normal message11.1 AS400 11.2 RS232 13.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up SafetyEDP70 PLUS/24/18/12 Internal Battery Shelves 13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle13.3 EDP70 Plus above 24KVA Battery Installation/Start-up 13.4 EDP70 Plus above 24KVA Battery CubicleEDP70 Plus System LOG