Garmin EDP70 manual QS1 QS4, QS2

Page 38

Computer relay interface - FEMALE

RAU - FEMALE

RS232 - MALE

Modem and

Multicom power supplies

REAR

QS1

QS4

 

QS3

 

PE U V W U1 V1W1 N U2 V2 W2

 

 

 

E.P.O.

Battery charge

QS2

 

inhibited

GROUND

PRIMARY INPUT

RESERVE INPUT

NEUTRAL (RES/OUT)

OUTPUT

EXTERNAL BATTERIES

Figure 23 - 36 – 24/30/36kVA: Cable Connections

page 38 --MI00/10056 rev. 8 — 4/2005

Image 38
Contents EDP70 Plus 2 --MI00/10056 rev -05/2006 Electric Shock Electrical PrecautionsEmergency Procedure Injuries Caused by Contact with Corrosive LiquidsContents Maintenance and Spare Parts Figures Equipment Delivery and Storage 8 -- MI00/10056 rev -05/2006 Introduction 36kVA 480V/208V Configuration 24kVA Standard Configuration36kVA Standard Configuration RECTIFIER/INVERTER 24/36kVA Ratings Contactor 24/36kVA Ratings Safety Eye goggles Rubber gloves Rubber apron Rubber boots Storage ALL Measurements are Millimeters and Inches 18 --MI00/10056 rev -05/2006 Cable Entry Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Cable Access PlateFuse Entry40.16 ConnectionPoints 32.68BTU/H Recommended wire sizes UPS Type = 2770 - - - e 0.125 h Tk / T0 T k Uninterruptible Power System No Unauthorized Operation Connection#$# % # #% + ,+% Nest Stationary Tool AWGM10 Indentor MoveableS2 = Equipment Reserve Switch Observe Polarities and Orientations Rear FrontRAU Female U1V1W1N PE U V W N U2V2W2 N36 --MI00/10056 rev -05/2006 36 24/30/36kVA Connections QS1 QS4 QS2Terminal board compartment 40 --MI00/10056 rev -05/2006 QS1 QS2 QS3 QS4 QS5 RearSignal connections Emergency Power Off Controls Right Control Maintenance Bypass Installing the EPO SHUT-DOWNLiquid Crystal Display Silencing Audible AlarmMimic LOAD/RES Alarms No Alarms Active RECT/BATT Alarms No Alarms ActiveInverter Alarms No Alarms Active Display Page HeadingsBattery Test Weekly Selected Language EnglishPower History Down to Access Load F xx.x Hz Xxx V B xxx V C Last Mains Failure xxd xxh xxm xxs Inverter F xx.x Hz AB xxx V BC xxx V CA xxx Vdc xxx V Ib xxxx aInverter F xx.x Hz Xxx V B xxx V C xxx InverterLoad System Alarm Abnormal operating mode messagesMain page Heading Alarms Message Condition Stop DUE to Overload Battery DischargingOverload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Power History MatrixResetting data loss manually Battery TestBattery Autonomy Test System normal message11.1 AS400 11.2 RS232 13.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up SafetyEDP70 PLUS/24/18/12 Internal Battery Shelves 13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle13.3 EDP70 Plus above 24KVA Battery Installation/Start-up 13.4 EDP70 Plus above 24KVA Battery CubicleEDP70 Plus System LOG