RECTIFIER/BATTERY ALARMS

 

 

 

MESSAGE

CONDITION

NOT CALIBRATED

FAULT

 

 

DC FEEDBACK FAULT

FAULT

 

 

VERIFY DC FEEDBACK

NORMAL

 

 

PRIMARY SUPPLY FAULT

WARNING

 

 

PHASE SEQUENCE ERROR

FAULT

 

 

BATTERY FAULT

FAULT

 

 

PCB SUPPLY FAULT

FAULT

 

 

BATT CONTACTOR OPEN

-

 

 

BATTERY DISCHARGING

WARNING

 

 

SHUTDOWN IMMINENT

WARNING

 

 

DC VOLTAGE HIGH

FAULT

 

 

DC VOLTAGE LOW

WARNING

 

 

INPUT SWITCH OPEN

FAULT

 

 

HARMONIC FILTER OPEN

FAULT

 

 

RECTIFIER ALARM

FAULT

 

 

RECTIFIER INHIBITED

WARNING

 

 

RECTIFIER BLOCKED

FAULT

 

 

BATT. CHARGE INHIBIT

WARNING

 

 

MI00/10056 rev. 8 — 05/2006-- page 57

Image 57
Contents EDP70 Plus 2 --MI00/10056 rev -05/2006 Emergency Procedure Electrical PrecautionsElectric Shock Injuries Caused by Contact with Corrosive LiquidsContents Maintenance and Spare Parts Figures Equipment Delivery and Storage 8 -- MI00/10056 rev -05/2006 Introduction 24kVA Standard Configuration 36kVA Standard Configuration36kVA 480V/208V Configuration RECTIFIER/INVERTER 24/36kVA Ratings Contactor 24/36kVA Ratings Safety Eye goggles Rubber gloves Rubber apron Rubber boots Storage ALL Measurements are Millimeters and Inches 18 --MI00/10056 rev -05/2006 Cable Entry Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Fuse Access PlateCable EntryPoints Connection40.16 32.68BTU/H Recommended wire sizes UPS Type = 2770 - - - e 0.125 h Tk / T0 T k Connection Uninterruptible Power System No Unauthorized Operation#$# % # #% + ,+% M10 AWGNest Stationary Tool Indentor MoveableS2 = Equipment Reserve Switch Observe Polarities and Orientations RAU Female FrontRear U1V1W1N PE U V W N U2V2W2 N36 --MI00/10056 rev -05/2006 36 24/30/36kVA Connections QS2 QS1 QS4Terminal board compartment 40 --MI00/10056 rev -05/2006 Rear QS1 QS2 QS3 QS4 QS5Signal connections Emergency Power Off Controls Right Control Maintenance Bypass SHUT-DOWN Installing the EPOSilencing Audible Alarm MimicLiquid Crystal Display Inverter Alarms No Alarms Active RECT/BATT Alarms No Alarms ActiveLOAD/RES Alarms No Alarms Active Display Page HeadingsSelected Language English Battery Test WeeklyPower History Down to Access Load F xx.x Hz Xxx V B xxx V C Last Mains Failure xxd xxh xxm xxs Inverter F xx.x Hz Xxx V B xxx V C xxx Vdc xxx V Ib xxxx aInverter F xx.x Hz AB xxx V BC xxx V CA xxx InverterLoad Abnormal operating mode messages Main page Heading Alarms Message ConditionSystem Alarm Battery Discharging OverloadStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Matrix Power HistoryBattery Autonomy Test Battery TestResetting data loss manually System normal message11.1 AS400 11.2 RS232 Safety 13.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle EDP70 PLUS/24/18/12 Internal Battery Shelves13.4 EDP70 Plus above 24KVA Battery Cubicle 13.3 EDP70 Plus above 24KVA Battery Installation/Start-upEDP70 Plus System LOG