Garmin EDP70 manual Abnormal operating mode messages, Main page Heading Alarms Message Condition

Page 55

10.5Abnormal operating mode messages

Under abnormal operating conditions, the normal functioning heading on the main page

UPS xx KVA

SYSTEM NORMAL

is replaced with the alarm page:

UPS xx KVA

SYSTEM ALARM

If at least 1 alarm is activated for each block; the »NO ALARMS ACTIVE» message in the second line on the display is replaced with the first active alarm. Whenever there is more than one active alarm, they can be scrolled through using the

and keys.

Each message is associated with one of the following conditions:

￿￿￿￿￿￿

Conditions which do not adversely affect the normal functioning of the machine are identified under this heading.

No action is required on the part of the operator.

￿￿￿￿￿￿￿

Transitory conditions which can either return to normal condition or result in a permanent fault are identified under this heading. No action is required on the part of the operator.

￿￿￿￿￿

Faults are identified under this heading. The intervention of a qualified technician is required.

Alarms which do not come under any of these headings do not require any action if arising separately.

MAIN PAGE HEADING ALARMS

 

 

 

MESSAGE

CONDITION

TESTING BATTERY

NORMAL

 

 

EPO ACTIVE

WARNING

 

 

NOT CALIBRATED

FAULT

 

 

TESTING AUTONOMY

WARNING

 

 

SYSTEM TEST MODE

FAULT

 

 

MI00/10056 rev. 8 — 05/2006-- page 55

Image 55
Contents EDP70 Plus 2 --MI00/10056 rev -05/2006 Injuries Caused by Contact with Corrosive Liquids Electrical PrecautionsEmergency Procedure Electric ShockContents Maintenance and Spare Parts Figures Equipment Delivery and Storage 8 -- MI00/10056 rev -05/2006 Introduction 36kVA Standard Configuration 24kVA Standard Configuration36kVA 480V/208V Configuration RECTIFIER/INVERTER 24/36kVA Ratings Contactor 24/36kVA Ratings Safety Eye goggles Rubber gloves Rubber apron Rubber boots Storage ALL Measurements are Millimeters and Inches 18 --MI00/10056 rev -05/2006 Cable Entry Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 24/36kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Battery Cabinet Drawing for 50/80kVA Ratings Entry Access PlateFuse Cable32.68 ConnectionPoints 40.16BTU/H Recommended wire sizes UPS Type = 2770 - - - e 0.125 h Tk / T0 T k Connection Uninterruptible Power System No Unauthorized Operation#$# % # #% + ,+% Indentor Moveable AWGM10 Nest Stationary ToolS2 = Equipment Reserve Switch Observe Polarities and Orientations U1V1W1N PE U V W N U2V2W2 N FrontRAU Female Rear36 --MI00/10056 rev -05/2006 36 24/30/36kVA Connections QS2 QS1 QS4Terminal board compartment 40 --MI00/10056 rev -05/2006 Rear QS1 QS2 QS3 QS4 QS5Signal connections Emergency Power Off Controls Right Control Maintenance Bypass SHUT-DOWN Installing the EPOMimic Silencing Audible AlarmLiquid Crystal Display Display Page Headings RECT/BATT Alarms No Alarms ActiveInverter Alarms No Alarms Active LOAD/RES Alarms No Alarms ActiveSelected Language English Battery Test WeeklyPower History Down to Access Load F xx.x Hz Xxx V B xxx V C Last Mains Failure xxd xxh xxm xxs Inverter Vdc xxx V Ib xxxx aInverter F xx.x Hz Xxx V B xxx V C xxx Inverter F xx.x Hz AB xxx V BC xxx V CA xxxLoad Main page Heading Alarms Message Condition Abnormal operating mode messagesSystem Alarm Overload Battery DischargingStop DUE to Overload RECTIFIER/BATTERY Alarms Message Condition Inverter Alarms Message Condition LOAD/RESERVE Alarms Message Condition Power History Matrix Power HistorySystem normal message Battery TestBattery Autonomy Test Resetting data loss manually11.1 AS400 11.2 RS232 Safety 13.1 EDP70 PLUS/24/18/12 Battery Installation/Start-up13.2 EDP70 PLUS/24/18/12 Optional Battery Cubicle EDP70 PLUS/24/18/12 Internal Battery Shelves13.4 EDP70 Plus above 24KVA Battery Cubicle 13.3 EDP70 Plus above 24KVA Battery Installation/Start-upEDP70 Plus System LOG