Runco PL-61CX manual  Orbiter settings,  Orbiter Function settings,  Inverse Settings

Page 52

LOCK1, 2, 3 .... Sets maximum brightness.

The brightness level decreases in the order of LOCK 1, 2, 3. LOCK 3 provides minimum brightness.

ORBITER

Use this to set the picture shift.

Example: Setting “ORBITER” to “AUTO1”

Perform Steps 1-2 of LONG LIFE, then...

3.Use the and buttons to select “ORBITER”.

4.Use the  and  buttons to select “AUTO1”.

The mode switches as follows each time the  or  button is pressed:

OFF AUTO1 AUTO2 MANUAL

 

 

 

 

LONG LIFE

 

 

PLE

:

AUTO

 

ORBITER

 

:

AUTO1

 

 

 

 

 

 

INVERSE

:

OFF

SCREEN WIPER

:

OFF

SOFT FOCUS

:

OFF

 

 

SEL.

ADJ.

 

RETURN

 

 

EXIT

Information

ORBITER settings

OFF .............. Orbiter mode does not function.

This is the default setting when RGB is input.

AUTO1 ......... The picture moves around the screen

intermittently, making the picture smaller. This is the default setting when a Video or a DVD/HD/DTV singnal is input. Set to “OFF” when these signals are not used.

AUTO2 ......... The picture moves around the screen

intermittently, making the picture bigger.

MANUAL ...... User can adjust the orbiter function

(Horizontal Dot, Vertical Line and Time) manually.

See the following explanation.

*When a Video or a DVD/HD/DTV singnal is input, the AUTO1 and 2 functions will affect only the moving picture and will not make the screen smaller or bigger.

Adjust the ORBITER function manually

Set the amount of shift and the time between movement.

Example: Setting so that the picture moves 2 dots horizontally and 3 lines vertically every 3 minutes.

Perform Steps 1-3 of ORBITER, then...

4.Use the  and  buttons to select “MANUAL”, then press the MENU/ENTER button.

THE “ORBITER” screen appears.

5.Adjust the items using the ▲▼  and  buttons.

The mode switches as follows each time the  or  button is pressed:

H-DOT

1 DOT 2 DOT ..... 19 DOT 20 DOT

V-LINE

1 LINE 2 LINE ..... 19 LINE 20 LINE

• TIME

1 M 2 M 3 M

4 M

5 M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORBITER

 

 

 

 

 

 

 

:

2 DOT

 

 

H-DOT

 

 

 

 

 

 

 

 

V-LINE

:

4 LINE

 

TIME

:

3 M

SEL.

ADJ.

EXIT

RETURN

Information

ORBITER Function settings

H-DOT

Moves from 1 to 20 dots in the

 

horizontal direction.

V-LINE

Moves from 1 to 20 lines in the vertical

 

direction.

TIME

Interval of 1~5 minutes (1 horizontal

 

dot or 1 vertical line per interval).

INVERSE

Use this to set the inverse mode or to display a white screen.

Example: Setting “INVERSE” to “WHITE”

Perform Steps 1-2 of LONG LIFE, then...

3.Use the and buttons to select “INVERSE”.

4.Use the  and  buttons to select “WHITE”.

The mode switches as follows each time the  or  button is pressed:

OFF ON WHITE

 

 

 

 

LONG LIFE

 

 

PLE

:

AUTO

ORBITER

:

OFF

 

INVERSE

 

:

WHITE

 

 

 

 

 

 

SCREEN WIPER

:

OFF

SOFT FOCUS

:

OFF

 

 

SEL.

ADJ.

 

RETURN

 

 

EXIT

Information

INVERSE Settings

ON ......... The picture is displayed alternately between

positive image and negative image.

You can set the time by pressing the MENU/ ENTER button while “ON” is set.

OFF ....... Inverse mode does not function.

WHITE ... The entire screen turns white.

You can set the time by pressing the MENU/ ENTER button while “ON” is set.

42

Image 52
Contents PL-61cx Table of Contents External Control Features you’ll enjoy include Contents of the packageIntroduction OptionsImportant Information PrecautionsRisk of Electric Shock Do not Open To avoid damage and prolong operating life Plasma monitor cleaning procedureRecommendations to avoid or minimize phosphor burn-in Three Year Limited Warranty RIGHTS, Limits and Exclusions TWO Year Limited Warranty RIGHTS, Limits and Exclusions How to Attach Options to the Plasma Monitor Turns the plasma monitor’s power on and off Receives the signals from the remote controlSets the On-Screen Menu mode and displays the main menu Part Names and FunctionRear View / Terminal Board Connect the included power cord hereConnect DVD’s, High Definition or Laser Discs, etc here Installation Remote Control Use of Installation Remote Control Battery Installation and Replacement Operating Range Using the wired remote control mode1/8 Stereo Mini cable must be purchased separeately Plasma Monitor Installation VideoConnecting Your Document Camera Connecting Your VCR or Laser Disc PlayerConnecting Your DVD Player Connections with Equipment that have a Digital InterfacePin Assignments and Signal Levels for 15 pin RGB Analog Pin No Signal AnalogCreating a video wall Cable ManagementPFP Controller Installation & Overall Description PFP Controller Description Front PanelRear Panel RGB Output Video InputsPFP Controller Remote Description Quick Set-up Guide Connection ExamplesMenu Tree Main MenuPicture Quality Adjustments Page Page Installation Menu Side Bar LevelInvert Input Shift Output ShiftIR Code Select Blanking System ResetBlanking Basic Operations To set the off timer To cancel the off timerAfter the power is turned off with the off timer To check the remaining timeWhen viewing videos or digital video discs Wide OperationsWide Screen Operation with Computer Signals When Picture Size is set to OFF Supported resolution  Picture Size setting Advanced menu mode Menu OperationsReset Menu TreeOPTION2 PWR. MGT Picture Settings Menu Adjusting the pictureAdjusting the color to the desired level Setting the color temperatureReducing noise in the picture Making the Low Tone adjustments  Adjusting the white balance Gamma settings  LOW Tone settingsAudio Settings Menu Adjusting the colors Color Tune settings  Audio settings menuImage Adjust Settings Menu Setting the allocation of the audio connectorsAdjusting the Position, Size, Fine Picture, Picture Adj Example Setting Audio INPUT1 to VideoOption1 Settings Menu Setting the on-screen menuSetting the BNC connectors Checking the signal being transmitted to RGB1 terminalSetting a computer image to the correct RGB select screen  OSM Orbiter settingsSetting high definition images to the suitable screen size Setting the Input Skip Input Skip settings  RGB Select modesResetting to the default values Option2 Settings MenuSetting the power management for computer images POWER/STANDBY indicator Setting the picture to suit the movie PLE settings Reducing burn-in of the screen Orbiter Function settings  Orbiter settings Inverse Settings  To select on for the Working Time  Setting the timeScreen Wiper Setting the screen size for S1/S2 video input  Soft Focus settingsSetting the gray level for the sides of the screen  Gray Level settingsSetting the picture size for RGB input signals Setting the signal and black level for DVI signal S1/S2 settings  PLUG/PLAY settingsOption3 Settings Menu Using the timer Present Time settings Present TimeSetting the power on mode  To reset the program To reset the data  Special characters in the Program Timer screenEnabling/disabling remote control wireless transmission  PWR. on Mode settings Control Lock settings  IR Remote settingsLoop Out setting ID number settingVideo Wall setting  Divider settings Video Wall Position settings Screens DISP. Mode settings  Auto ID settings Image Adjust settings On Delay Power on delay  P. on Delay settings PLE Link settings PLE LinkAdvanced OSM Settings Menu Setting the menu modeRepeat Timer  Repeat Timer settingsLanguage Settings Menu Color System Settings MenuSetting the language for the menus Setting the video signal formatExternal Control ApplicationConnections Communication ParametersSupported resolution Table of Signals SupportedComputer input signals supported by this system PFP Controller RS-232 Communications General InformationPFP Controller RS-232 Commands Parameter min/max Value stored?Store YES Troubleshooting Symptom Checks RemedyPage After initial installation. Power LED on the frontYellow after the power button Plasma does not turn onOn, and the power LED on Image appears tooBright, and there is a loss Definition in the brightWeight 140 lbs .5 kg 1366 xDiagonal 169Pfptm Controller Specifications & Dimensions RUMA-006830-SPL