Sierra 241-VTP, 240-VTP instruction manual Appendix a Specifications

Page 68

 

Appendix A Specifications

 

 

 

 

 

 

Series 24-HP Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Air Minimum and Maximum Flow Rates (SCFM)

 

 

 

 

 

 

 

 

Air at 70oF

 

 

 

 

 

 

 

 

 

 

Nominal Pipe Size (in)

 

 

 

 

 

 

Pressure

0.5

0.75

1

 

1.5

2

 

3

 

4

6

8

 

0 psig

1.8

3

5

 

13

22

 

50

 

87

198

347

 

18

41

90

 

221

369

 

826

 

1437

3258

5708

 

 

 

 

 

 

100 psig

5

9

15

 

38

63

 

141

 

245

555

972

 

138

325

704

 

1730

2890

 

6466

 

11254

25515

44698

 

 

 

 

 

 

200 psig

7

13

21

 

52

86

 

193

 

335

761

1332

 

258

609

1322

 

3248

5427

 

12140

 

21131

47911

83931

 

 

 

 

 

 

300 psig

8

15

25

 

63

104

 

234

 

407

922

1615

 

380

896

1944

 

4775

7978

 

17847

 

31064

70431

123375

 

 

 

 

 

 

400 psig

10

18

29

 

72

120

 

269

 

467

1060

1857

 

502

1183

2568

 

6309

10542

 

23580

 

41043

93057

163000

 

 

 

 

 

 

500 psig

11

20

33

 

80

134

 

300

 

521

1182

2071

 

624

1472

3195

 

7849

13115

 

28034

 

51063

115775

203000

 

 

 

 

 

 

 

 

 

Typical Air Minimum and Maximum Flow Rates (nm3/hr)

 

 

 

 

 

 

 

 

Air at 20oC

 

 

 

 

 

 

 

 

 

 

Nominal Pipe Size (mm)

 

 

 

 

Pressure

 

15

 

20

25

40

 

50

80

100

 

150

200

0 barg

 

3

 

5

9

21

 

36

79

138

 

313

549

 

28

 

66

142

350

 

584

1307

2275

 

5157

9034

 

 

 

 

 

5 barg

 

7

 

13

21

52

 

87

194

337

 

764

1339

 

165

 

390

847

2080

 

3476

7775

13533

 

30682

53749

 

 

 

 

 

10 barg

 

9

 

17

29

70

 

117

262

457

 

1035

1814

 

304

 

716

1554

3819

 

6381

14273

24844

 

56329

98676

 

 

 

 

 

15 barg

 

11

 

21

34

85

 

142

317

551

 

1250

2190

 

442

 

1044

2265

5565

 

9299

20801

36205

 

82087

143801

 

 

 

 

 

20 barg

 

13

 

24

40

97

 

162

363

632

 

1434

2511

 

582

 

1373

2979

7318

 

12229

27354

47612

 

107949

189105

 

 

 

 

 

30 barg

 

16

 

29

48

118

 

198

442

770

 

1745

3057

 

862

 

2034

4414

10843

 

18119

40529

70544

 

159942

280187

 

 

 

 

 

Linear Range

 

Smart electronics corrects for lower flow down to a Reynolds number of 5,000. The Reynolds

 

 

 

 

 

 

number is calculated using the fluid’s actual temperature and pres-

 

 

 

 

 

 

sure monitored by the meter. Rangeability depends on the fluid,

 

 

 

 

 

 

process connections and pipe size. Consult factory for your applica-

 

 

 

 

 

 

tion. Velocity rangeability under ideal conditions is as follows:

 

 

 

Liquids 30:1

 

1 foot per second velocity minimum

 

 

 

 

 

 

 

 

 

30 feet per second velocity maximum

 

 

 

 

 

Gases 30:1

 

10 feet per second velocity minimum

 

 

 

 

 

 

 

 

 

300 feet per second velocity maximum

 

A-2

IM-24-HP

Image 68
Contents Models 240-VT, 240-VTP, 241-VT, 241-VTP Customer Notice Copyright Sierra InstrumentsTable of Contents Troubleshooting and Repair Figures TablesTable of Contents Innova-MassMulti-Parameter Vortex Mass Flow Meters Using This ManualIntroduction Receipt of System Components Technical AssistanceHow the Innova-Mass Vortex Mass Flow Meter Operates Velocity MeasurementVortex Shedding Frequency Vortex Frequency SensingFlow Velocity Range Gas LiquidTemperature Measurement Reynolds Number Range for the Innova-MassFlow Meter Configurations Pressure MeasurementFlow Meter Electronics Flow Meter Installation Requirements InstallationInstallation Overview Unobstructed Flow Requirements Series 240 In-Line Flow Meter Installation Flange Bolt SpecificationsWafer-Style Flow Meter Installation Wafer-Style Flow Meter InstallationFlange-Style Flow Meter Installation Flange-Style Flow Meter InstallationIsolation Valve Selection Series 241 Insertion Flow Meter InstallationMounting Position Cold Tap Guidelines Hot Tap Guidelines FlowFlow Meter Insertion Use the Correct Insertion FormulaInstalling Flow Meters with a Compression Connection ExampleInsertion Procedure for Meters with a Compression Connection Example 2 NPT Style Meters Installing Flow Meters with a Packing Gland ConnectionExample 1 Flange Style Meters Flow Meter with Permanent Insertion Tool 10. Flow Meter with Removable Insertion Tool 11. Insertion Calculation Meters without Insertion Tool Installation Adjusting Meter Orientation Display/Keypad Adjustment All MetersEnclosure Adjustment Series 240 Only 13. Enclosure Viewing AdjustmentWiring Connections Input Power ConnectionsAC Power Wiring DC Power WiringMA Output Connections 16. Load Resistance Versus Input VoltagePulse Output Connections 20. Isolated Pulse Output with External Power Supply Alarm Output Connections 23. Isolated Alarm Output with External Power SupplyRemote Electronics Wiring 25. Isolated Alarm Output Using Meter Provided Power SupplyOptional Input Electronics Wiring Optional Energy EMS Input Electronics WiringPage Sierra Operating InstructionsFlow Meter Display/Keypad Run Mode Screens Start-UpUsing the Setup Menus Programming the Flow MeterOutput Menu TimeConstSec XxxxExample for Setting an Output First, set the desired units of measurementExample for Changing a Run Mode Display Item Display MenuAlarms Menu Example for Setting an AlarmExample for Setting the Totalizer Totalizer #1 MenuTotalizer #2 Menu Configuration Energy Menu For EMS Energy Meters OnlyFluid Menu Units Menu Example for Setting the Time Time & Date MenuDiagnostics Menu Calibration Menu Password Menu Troubleshooting and Repair Hidden Diagnostics MenusColumn One Hidden Diagnostics Values IM-24-HP A2D Ref. Resistor = Factory Use Only Analog Output Calibration Troubleshooting the Flow Meter Symptom Output at no Flow Symptom No Output Symptom Meter Displays Temperature Fault Electronics Assembly Replacement All Meters Pressure Sensor Replacement Appendix a Product Specifications Appendix a Specifications Appendix a Specifications Cnpt IP66, Nema Page Appendix B Glossary C DK L S T Page Appendix C Fluid Calculations Calculations for Steam T & PDensity ViscosityCalculations for Gas Real Gas and Other Gas Density for real gases is calculated from the equationCalculations for Liquid Page Appendix D Hart Commands with DD Menu PV AOAppendix D Hart Commands without DD Menu PV AO PV LRV URVAppendix E Modbus Communication Applicable Flow Meter ModelsModbus Order Register Definitions Appendix E Modbus Commands Following registers contain the display units strings Control Register Definitions Examples An attempt to read registers that don’t exist 8C 3A CRC not the correct CRC EJS-02-06-07 Appendix E Modbus Commands