Sierra 240-VTP, 241-VTP instruction manual IP66, Nema

Page 71

Series 24-HP Instruction Manual

Appendix A Specifications

 

 

 

Pocess Fluid and

Process Fluid:

Ambient Temperature

Standard temperature sensor: –40°F to 500°F (–40°C to 260°C).

 

High temperature sensor: to 750°F ( to 400°C).

 

Ambient:

 

Operating: –5°F to 140°F (–20°C to 60°C).

 

Storage: –40°F to 150°F (–40°C to 65°C).

 

0-98% relative humidity, non-condensing conditions.

Output Signals (1)

Analog: Volumetric Meter: field rangeable linear 4-20 mA output

 

signal (1000 Ohms maximum loop resistance) selected by user for

 

mass flow rate or volumetric flow rate.

 

Communications: HART, MODBUS, RS485

 

Multiparameter Meter: up to three field rangeable linear 4-20 mA

 

output signals (1000 Ohms maximum loop resistance) selected

 

from the five parameters–mass flow rate, volumetric flow rate, tem-

 

perature, pressure and density.

 

Pulse:Pulse output for totalization is a 50-millisecond duration pulse

 

operating a solid-state relay capable of switching 40 VDC, 40 mA

 

maximum.

 

Note: (1) All outputs are optically isolated and require external power

 

for operation.

Alarms

Up to three programmable solid-state relays for high, low or window

 

alarms capable of switching 40 VDC, 40 mA maximum.

Totalizer

Based on user-determined flow units, six significant figures in sci-

 

entific notation. Total stored in non-volatile memory.

Wetted Materials

Series 240 In-Line Flow Meter:

 

316L stainless steel standard.

 

C276 hastelloy or A105 carbon steel optional.

 

Series 241 Insertion Flow Meter:

 

316L stainless steel standard.

 

Teflon® packing gland below 500°F (260°C).

 

Graphite packing gland above 500°F (260°C).

Enclosure

NEMA 4X cast enclosure.

Electrical Ports

Two 3/4-inch female NPT ports.

Mounting Connections

Series 240: Wafer, 150, 300, 600 lb ANSI flange, PN16, PN40,

 

PN64 flange.

 

Series 241 Permanent installation: 2-inch MNPT; 150, 300, 600 lb

 

ANSI flange, PN16, PN40, PN64 flange with compression fitting

 

probe seal.

 

Series 241 Hot Tap(1) Installation: 2-inch MNPT; 150, 300, 600 lb

 

ANSI flange, PN16, PN40, PN64 flange and optional retractor with

 

packing gland probe seal.

 

Note: (1) Removable under line pressure.

Mounting Position

Series 240 In-Line Flow Meter: No effect.

 

Series 241 Insertion Flow Meter: Meter must be perpendicular

 

within ± 5°of the pipe centerline.

Certifications

Construction Inspection ( ANSI/ASME B31.3).

 

Materials (NACE MR-01-75[90]).

 

CE and FM approved.

 

CSA, CENELEC approval pending.

 

FM approvals:

 

Class I, Division 1, Groups B, C, & D, T6 at Tamb = 60°C

 

Class II/III, Division 1, Groups E, F, & G

 

IP66, NEMA 4X

 

 

 

IM-24-HP

A-5

Image 71
Contents Models 240-VT, 240-VTP, 241-VT, 241-VTP Copyright Sierra Instruments Customer NoticeTable of Contents Troubleshooting and Repair Tables FiguresTable of Contents Innova-MassMulti-Parameter Vortex Mass Flow Meters Using This ManualIntroduction Technical Assistance Receipt of System ComponentsVelocity Measurement How the Innova-Mass Vortex Mass Flow Meter OperatesVortex Frequency Sensing Vortex Shedding FrequencyGas Liquid Flow Velocity RangeReynolds Number Range for the Innova-Mass Temperature MeasurementPressure Measurement Flow Meter ConfigurationsFlow Meter Electronics Flow Meter Installation Requirements InstallationInstallation Overview Unobstructed Flow Requirements Flange Bolt Specifications Series 240 In-Line Flow Meter InstallationWafer-Style Flow Meter Installation Wafer-Style Flow Meter InstallationFlange-Style Flow Meter Installation Flange-Style Flow Meter InstallationIsolation Valve Selection Series 241 Insertion Flow Meter InstallationMounting Position Cold Tap Guidelines Flow Hot Tap GuidelinesUse the Correct Insertion Formula Flow Meter InsertionExample Installing Flow Meters with a Compression ConnectionInsertion Procedure for Meters with a Compression Connection Example 2 NPT Style Meters Installing Flow Meters with a Packing Gland ConnectionExample 1 Flange Style Meters Flow Meter with Permanent Insertion Tool 10. Flow Meter with Removable Insertion Tool 11. Insertion Calculation Meters without Insertion Tool Installation Display/Keypad Adjustment All Meters Adjusting Meter Orientation13. Enclosure Viewing Adjustment Enclosure Adjustment Series 240 OnlyDC Power Wiring Wiring ConnectionsInput Power Connections AC Power Wiring16. Load Resistance Versus Input Voltage MA Output ConnectionsPulse Output Connections 20. Isolated Pulse Output with External Power Supply 23. Isolated Alarm Output with External Power Supply Alarm Output Connections25. Isolated Alarm Output Using Meter Provided Power Supply Remote Electronics WiringOptional Energy EMS Input Electronics Wiring Optional Input Electronics WiringPage Sierra Operating InstructionsFlow Meter Display/Keypad Start-Up Run Mode ScreensProgramming the Flow Meter Using the Setup MenusTimeConstSec Xxxx Output MenuFirst, set the desired units of measurement Example for Setting an OutputDisplay Menu Example for Changing a Run Mode Display ItemExample for Setting an Alarm Alarms MenuTotalizer #1 Menu Example for Setting the TotalizerTotalizer #2 Menu Energy Menu For EMS Energy Meters Only ConfigurationFluid Menu Units Menu Time & Date Menu Example for Setting the TimeDiagnostics Menu Calibration Menu Password Menu Hidden Diagnostics Menus Troubleshooting and RepairColumn One Hidden Diagnostics Values IM-24-HP A2D Ref. Resistor = Factory Use Only Analog Output Calibration Troubleshooting the Flow Meter Symptom Output at no Flow Symptom No Output Symptom Meter Displays Temperature Fault Electronics Assembly Replacement All Meters Pressure Sensor Replacement Appendix a Product Specifications Appendix a Specifications Appendix a Specifications Cnpt IP66, Nema Page C D Appendix B GlossaryK L S T Page Viscosity Appendix C Fluid CalculationsCalculations for Steam T & P DensityDensity for real gases is calculated from the equation Calculations for Gas Real Gas and Other GasCalculations for Liquid Page PV AO Appendix D Hart Commands with DD MenuPV AO PV LRV URV Appendix D Hart Commands without DD MenuApplicable Flow Meter Models Appendix E Modbus CommunicationModbus Order Register Definitions Appendix E Modbus Commands Following registers contain the display units strings Control Register Definitions Examples An attempt to read registers that don’t exist 8C 3A CRC not the correct CRC EJS-02-06-07 Appendix E Modbus Commands