Page 12

Chapter 3 — Hardware Setup

Contents

off

on

on

off

on

on

28

off

on

on

on

off

off

29

off

off

on

on

off

on

30

off

on

on

on

on

off

31

off

on

on

on

on

on

32

on

off

off

off

off

off

33

on

off

off

off

off

on

34

on

off

off

off

on

off

35

on

off

off

off

on

on

36

on

off

off

on

off

off

37

on

off

off

on

off

on

38

on

off

off

on

on

off

39

on

off

off

on

on

on

40

on

off

on

off

off

off

41

on

off

on

off

off

on

42

on

off

on

off

on

off

43

on

off

on

off

on

on

44

on

off

on

on

off

off

45

on

off

on

on

off

on

46

on

off

on

on

on

off

47

on

off

on

on

on

on

48

on

on

off

off

off

off

49

on

on

off

off

off

on

50

on

on

off

off

on

off

51

on

on

off

off

on

on

52

on

on

off

on

off

off

53

on

on

off

on

off

on

54

on

on

off

on

on

off

55

on

on

off

on

on

on

56

on

on

on

off

off

off

57

on

on

on

off

off

on

58

on

on

on

off

on

off

59

on

on

on

off

on

on

60

on

on

on

on

off

off

61

on

off

on

on

off

on

62

on

on

on

on

on

off

63

on

on

on

on

on

on

64

Switch SW 2

Function

Description

Details

 

 

 

Fault on

When enabled, the

SW2-8

Loss of

1560-MBP will fault the

Off = Disable fault on loss

Modbus

connected SCANport

of Modbus Plus

Plus

device if the Control

On = Enable fault on loss of

 

Word is not updated

Modbus Plus

 

within 10 seconds.

 

 

Note that the fault is not

 

 

enabled until after

 

 

Modbus Plus

 

 

communications have

 

 

been initially

 

 

established.

 

 

 

 

12

Image 12
Contents 1560 Table of Contents Please Read This Notice Quick Start Guide Step-by-StepRevisions Product Specifications Modbus Plus SpecificationsGeneral Specifications Configuration via dip switches Slave Address Host Address24 VDC Operating Temp To 50 C Storage Temp 40 to 85 C Supported Mstr Programming Commands Modbus Plus Port FunctionalityModbus Plus Communications Modbus Register Map Mstr Type 5 Write Global DataMBP Modbus Address Space Hardware Setup 1560-MBP Card Setup Connecting Power to the 1560-MBP CardDip Switch Configuration Switch SW Function Description Details Fault on LossModbus PlusSwitch SW 2 cont’d Contents Writing to the 1560-MBP Global Data Enabled Mstr Type Programming Considerations1560-MBP Global Data Enable 40400 Active Abort Error 40410Modicon Programming Example Mstr SuccessHost Issued Write Commands Mstr Type Reading from the 1560-MBP Global Data Mstr TypeModicon Programming Example Mstr Type Host Issued Read Commands Mstr Type Enable 40500 Active40510 0001040050 4006000020 MBP Status Registers 40021 to Modbus Name Values Description AddressBatch At this time Troubleshooting LED Troubleshooting TableLED Locations SCANport Mbpstat Diagnostics Cable Diagram TxRxD+Technical Support Technical Support ContactsAppendix a MBP Modbus Register MapMBP Modbus Appendix B Device Specific HintsSetting up the Adaptor I/O Data Logic Control Word Bit Function DescriptionDrive Status Word Bit Function Description Hardware Configuration Appendix CSingle Drive Peer Cop Application Example OverviewSwitch Position Description Configuration Extension BlocksPLC REF Drive Status Ladder Logic Programming RefOffset DescriptionPLC Ref PLC Name Description Special Precautions and hints TimingAddressing HintsAppendix D Mounting and SCANport Cabling InstructionsMounting Instructions 70mmCable Requirements Appendix E SCANport Datalink OperationRepair and Warranty Service and RepairGeneral Warranty Policy Hardware Product Warranty Details Limitation of LiabilityContents