SMC Networks 1560 user manual Please Read This Notice

Page 3

Contents

Please Read This Notice

Successful application of the 1560-MBP card requires a reasonable working knowledge of the Allen-Bradley hardware to be interfaced with, and the application in which the combination is to be used. For this reason, it is important that those responsible for implementing the 1560-MBP satisfy themselves that the 1560-MBP and Allen-Bradly hardware combination will meet the needs of the application without exposing personnel or equipment to unsafe or inappropriate working conditions.

This manual is provided to assist the user. Every attempt has been made to assure that the information provided is accurate and a true reflection of the product’s installation requirements.

In order to assure a complete understanding of the operation of the 1560-MBP, the user should read all applicable documentation on the operation of the Allen-Bradley hardware.

Under no conditions will ProSoft Technology, Inc. be responsible or liable for indirect or consequential damages resulting form the use or application of the 1560-MBP product.

Reproduction of the contents of this manual, in whole or in part, without written permission from ProSoft Technology, Inc. is prohibited.

Information in this manual is subject to change without notice and does not represent a commitment on the part of ProSoft Technology, Inc. Improvements and/or changes in this manual or the product may be made at any time. These changes will be made periodically to correct technical inaccuracies or typographical errors.

WARNING

The 1560-MBP card will allow remote access to commands in the Allen-Bradley drives and other Scanport compatible devices. The User is responsible for assuring that any applicable regulations concerning the remote operation of

equipment are adhered to.

© ProSoft Technology, Inc. 1997, 1998

Modbus Plus is a Trademark of Schneider Automation

3

Image 3
Contents 1560 Table of Contents Please Read This Notice Step-by-Step Quick Start GuideRevisions Configuration via dip switches Slave Address Host Address Product SpecificationsModbus Plus Specifications General Specifications24 VDC Operating Temp To 50 C Storage Temp 40 to 85 C Supported Mstr Programming Commands Modbus Plus Port FunctionalityModbus Plus Communications Modbus Register Map Mstr Type 5 Write Global DataMBP Modbus Address Space Hardware Setup 1560-MBP Card Setup Connecting Power to the 1560-MBP CardDip Switch Configuration Switch SW Plus Function Description Details Fault onLoss ModbusSwitch SW 2 cont’d Contents Programming Considerations Writing to the 1560-MBP Global Data Enabled Mstr Type1560-MBP Global Data Success Enable 40400 ActiveAbort Error 40410 Modicon Programming Example MstrHost Issued Write Commands Mstr Type Reading from the 1560-MBP Global Data Mstr TypeModicon Programming Example Mstr Type 00010 Host Issued Read Commands Mstr TypeEnable 40500 Active 4051040050 4006000020 Modbus Name Values Description Address MBP Status Registers 40021 toBatch At this time Troubleshooting LED Troubleshooting TableLED Locations SCANport Mbpstat Diagnostics TxRxD+ Cable DiagramTechnical Support Contacts Technical SupportAppendix a MBP Modbus Register MapMBP Modbus Device Specific Hints Appendix BSetting up the Adaptor I/O Data Logic Control Word Bit Function DescriptionDrive Status Word Bit Function Description Overview Hardware ConfigurationAppendix C Single Drive Peer Cop Application ExampleConfiguration Extension Blocks Switch Position DescriptionPLC REF Drive Status Ladder Logic Programming RefOffset DescriptionPLC Ref PLC Name Description Timing Special Precautions and hintsHints Addressing70mm Appendix DMounting and SCANport Cabling Instructions Mounting InstructionsCable Requirements SCANport Datalink Operation Appendix ERepair and Warranty Service and RepairGeneral Warranty Policy Limitation of Liability Hardware Product Warranty DetailsContents