SMC Networks 1560 Modbus Register Map, Mstr Type 5 Write Global Data, MBP Modbus Address Space

Page 9

Chapter 2 — Modbus Plus Port Functionality

Contents

MSTR Type 5 Write Global Data

This command is used in a host processor to ‘publish’ Global Data which all slaves on the Modbus Plus highway may access. The 1560-MBP units can be configured to read the Control and Reference values from this Global Data table.

2.1.2 Modbus Register Map

A pre-defined register map has been provided in the 1560- MBP unit. This map is detailed in Appendix A, and shown below. The full memory map is dependent on the A-B device which is connected to the 1560-MBP unit.

On power-up, the 1560-MBP unit polls the remote device and determines the maximum number of parameters that exist in the SCANport device. If the number is greater than 2000 the parameter list is limited to 2000.

1560-MBP Modbus

Address Space

 

 

Host

Global

Host

 

Global

Read

Write

Read

Write

(to Host)

MSTR 1

MSTR 2

MSTR 5

MSTR 6

40001

40011

40021

40101

Control, Reference and Datalink IN

Status, Reference and Datalink OUT

Miscellaneous

Parameter

(1)

(2)

(3)

4xxxx

(1)Note that 40001 and 40002 are only accessible with MSTR Type 1 if ‘Global Control’ is disabled in the 1560-MBP.

(2)Represents Control and Reference Words which are controlled by host when ‘Global Control’ is enabled.

(3)Words 40011 up to 40020 are ‘Published’ by 1560-MBP in the mode Global Data space. A host can access these values using a MSTR Type 6 instruction or Peer Cop (see Appendix C), or an MSTR Type 2 data read.

9

Image 9
Contents 1560 Table of Contents Please Read This Notice Step-by-Step Quick Start GuideRevisions Modbus Plus Specifications Product SpecificationsGeneral Specifications Configuration via dip switches Slave Address Host Address24 VDC Operating Temp To 50 C Storage Temp 40 to 85 C Supported Mstr Programming Commands Modbus Plus Port FunctionalityModbus Plus Communications Modbus Register Map Mstr Type 5 Write Global DataMBP Modbus Address Space Hardware Setup 1560-MBP Card Setup Connecting Power to the 1560-MBP CardDip Switch Configuration Switch SW Loss Function Description Details Fault onModbus PlusSwitch SW 2 cont’d Contents Programming Considerations Writing to the 1560-MBP Global Data Enabled Mstr Type1560-MBP Global Data Abort Error 40410 Enable 40400 ActiveModicon Programming Example Mstr SuccessHost Issued Write Commands Mstr Type Reading from the 1560-MBP Global Data Mstr TypeModicon Programming Example Mstr Type Enable 40500 Active Host Issued Read Commands Mstr Type40510 0001040050 4006000020 Modbus Name Values Description Address MBP Status Registers 40021 toBatch At this time Troubleshooting LED Troubleshooting TableLED Locations SCANport Mbpstat Diagnostics TxRxD+ Cable DiagramTechnical Support Contacts Technical SupportAppendix a MBP Modbus Register MapMBP Modbus Device Specific Hints Appendix BSetting up the Adaptor I/O Data Logic Control Word Bit Function DescriptionDrive Status Word Bit Function Description Appendix C Hardware ConfigurationSingle Drive Peer Cop Application Example OverviewConfiguration Extension Blocks Switch Position DescriptionPLC REF Drive Status Ladder Logic Programming RefOffset DescriptionPLC Ref PLC Name Description Timing Special Precautions and hintsHints AddressingMounting and SCANport Cabling Instructions Appendix DMounting Instructions 70mmCable Requirements SCANport Datalink Operation Appendix ERepair and Warranty Service and RepairGeneral Warranty Policy Limitation of Liability Hardware Product Warranty DetailsContents