Western Telematic CMS-16 manual Network Port Configuration Menu

Page 28

When a Resident Connection is initiated, the CMS will send a message which lists the connected ports, and displays the one character or three character disconnect command that will be required in order to terminate the connection.

The One Character Disconnect sequence is intended for situations where the destination port should not receive the disconnect command. When the Three Character format is selected, the disconnect sequence will pass through to the destination port prior to breaking the connection.

When the Three Character format is selected, the Resident Disconnect Sequence will use the format "[Enter]LLL[Enter]", where L is the selected Logoff Character.

When the One Character format is selected, resident connections are terminated by entering the selected Logoff Character only. There is no need to press [Enter] before and after the Logoff Character when the One Character format is selected.

11. Timeout Disconnect: Enables and selects the Timeout Period for this port. If enabled, and the port does not receive or transmit data for the specified Timeout Period, the port will disconnect. When the port is set for Any-to-Any Mode, Passive Mode, or Buffer Mode, the default setting for this item is "OFF". When the port is set for Modem Mode, the default setting for this item is 15 minutes.

12. Response Type: Selects the type of messages that this port will send in response to commands. The user can select Verbose (English Text), Terse (Numeric / Abbreviation), or Quiet Mode (No Response). (Default = Verbose).

13. Command Echo: Enables or Disables the command echo for this port. (Default = On).

14. Accept Break: Determines whether the port will accept breaks received from the attached device, and pass them along to a connected port. When enabled, breaks received at this port will be passed to any port that this port is connected to, and sent along to the device connected to the other port. When disabled, breaks will be refused at this port, and hence, not sent to the other port. (Default = Yes)

5.5.4. Network Port Configuration Menu

In order to communicate with the CMS via network, the IP Address, Subnet Mask, and Gateway Address must first be defined using the Network Parameters Menu. If desired, the Network Parameters menu also allows you to implement IP Security features, which can restrict command mode access based on the user's IP Address.

Settings for network parameters depend on the configuration of your individual network. Please

Image 28
Contents CMS-16 Battery Replacement Nameplate Power WarningRack Mount Installation Table of Contents Page Appendices List of FiguresIntroduction Front Panel Unit DescriptionTypographic Conventions Power Cable Receptacle Power Switch Back PanelGetting Started Using Other Parameters for this Overview OptionalCommunication Parameters Apply Power to the CMS System SetUp PortsConnecting your PC to the CMS Communicating with the CMS UnitCommand Menu Display Configuration ControlPort Name Password StatusHardware Installation Connecting Power to the CMS UnitAC Powered Units Configure Option SwitchesDC Powered Units Default Baud Rate Sw1, Sw2, Sw3 Default Handshake Sw4, Sw5Default Response Message Format Sw6 Initialize Unit to Default SettingsDefault Command Echo Sw7 Connecting Devices to the CMS Application ExampleCMS Application Example Not to Scale Configuration Access to the CMS Command Mode$ telnet 192.1.1.1 Enter Password Functions Supervisor PasswordDefining the Site ID and Supervisor Password Port PasswordsPort Configuration Configuration Conventions3. RS232 Port Configuration Menus Port ModesPort Parameters #02 CTS/RTSParameters #02 Stop Bits Default =ATZ AT&C1$D2S0=1 Network Port Configuration Menu Network Parameters Telnet Port ParametersPage Implementing IP Security IP SecurityPage Copying Parameters to All Ports Copy Port ParametersSave User Selected Parameters Status ScreensPort Status Screen /S Status Mode Buffer Count Port Status Screen Supervisor Mode, Defaults ShownPort Diagnostics Screen /SD DiagnosticsMode BUF CTS Name StatusNetwork Status Screen /SN Port Parameters Screens /W Network Status LAN StatusTelnet Port Status CMSPort Parameters #03 RTS/CTSOperation Any-to-Any ModePort Connection and Disconnection Disconnecting Ports Enter Defining Hunt Groups Hunt Group ExamplePassive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersSending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading CMS Firmware Command Reference Guide Command ConventionsCommand Response Command Summary Terse VerboseWP n Enter Command Set Enter Enter Command ModeEnter+++Enter Resident Disconnect Sequence ConnectFormat /C x x Enter CP Copy RS232 Port ParametersFormat /CP Enter Third Party DisconnectFormat /D/Y x x Enter 2 Enter or /D/Y 3 EnterErase Buffer Format /E/Y x x EnterHelp Default and TestDisplay Site ID Set RS232 Port Parameters Set Network Port ParametersDisplay Port Status SD Display Port Diagnostics Reset Network PortSN Display Network Status Save ParametersUF Upgrade Firmware Exit Command ModeFormat /UF Enter Display Port Parameters WhoAppendix A. RS232 Port Interface Appendix B. SpecificationsFormat /X Enter Power Appendix C. Customer ServiceStop Bits 1 or Trademark and Copyright Information Trademarks Used in this Manual