Western Telematic CMS-16 manual

Page 32

b.Masks are listed in order of ascending priority; Mask 1 has the lowest priority, and Mask 5 has the highest priority.

c.Masks have a cumulative effect; high priority masks supersede the effect of lower priority masks.

d.Each IP Address consists of a series of four eight bit numbers. The number 255 is used as a wild card.

Example 1: Deny access to all hosts except 192.1.1.5:

Security Mask #1: 255.255.255.255

Mask #1 Action: Deny

Security Mask #2: 192.1.1.5

Mask #2 Action: Permit

Since 255 is a wild card, Mask #1 blocks all IP Addresses. Mask #2 then specifically grants access to 192.1.1.5 only.

Example 2: Allow access only by addresses that begin with 192:

Security Mask #1: 255.255.255.255

Mask #1 Action: Deny

Security Mask #2: 192.255.255.255

Mask #2 Action: Permit

Since 255 is a wild card, Mask #1 blocks all IP addresses Mask #2 then grants access to all addresses that begin with 192.

Example 3: Allow access only by addresses that begin with 192, deny access to 192.1.1.5.

Security Mask #1: 255.255.255.255

Mask #1 Action: Deny

Security Mask #2: 192.255.255.255

Mask #2 Action: Permit

Security Mask #3: 192.1.1.5

Mask #3 Action: Deny

Since 255 is a wild card, Mask #1 blocks all IP addresses. Mask #2 then grants access to all addresses that begin with 192. Finally, Mask #3 specifically blocks access by 192.1.1.5.

Note:

Mask #5 has priority over the four other masks. If Mask #5 is set to deny access by "255.255.255.255" (all wild cards), all IP addresses will be blocked, and you will not be able to access the CMS Command Mode via network. Access will only be allowed via the Console Port or Modem Port.

Image 32
Contents CMS-16 Rack Mount Installation Nameplate Power WarningBattery Replacement Table of Contents Page Appendices List of FiguresIntroduction Typographic Conventions Unit DescriptionFront Panel Power Cable Receptacle Power Switch Back PanelCommunication Parameters Using Other Parameters for this Overview OptionalGetting Started Apply Power to the CMS System SetUp PortsConnecting your PC to the CMS Communicating with the CMS UnitCommand Menu Display Configuration ControlPort Name Password StatusHardware Installation Connecting Power to the CMS UnitDC Powered Units Configure Option SwitchesAC Powered Units Default Baud Rate Sw1, Sw2, Sw3 Default Handshake Sw4, Sw5Default Command Echo Sw7 Initialize Unit to Default SettingsDefault Response Message Format Sw6 Connecting Devices to the CMS Application ExampleCMS Application Example Not to Scale Configuration Access to the CMS Command Mode$ telnet 192.1.1.1 Enter Password Functions Supervisor PasswordDefining the Site ID and Supervisor Password Port PasswordsPort Configuration Configuration Conventions3. RS232 Port Configuration Menus Port ModesPort Parameters #02 CTS/RTSATZ Stop Bits Default =Parameters #02 AT&C1$D2S0=1 Network Port Configuration Menu Network Parameters Telnet Port ParametersPage Implementing IP Security IP SecurityPage Copying Parameters to All Ports Copy Port ParametersPort Status Screen /S Status ScreensSave User Selected Parameters Status Mode Buffer Count Port Status Screen Supervisor Mode, Defaults ShownPort Diagnostics Screen /SD DiagnosticsMode BUF CTS Name StatusNetwork Status Screen /SN Port Parameters Screens /W Network Status LAN StatusTelnet Port Status CMSPort Parameters #03 RTS/CTSPort Connection and Disconnection Any-to-Any ModeOperation Disconnecting Ports Enter Defining Hunt Groups Hunt Group ExamplePassive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersRestoring Saved Parameters Saving and Restoring Configuration ParametersSending Parameters to a File Upgrading CMS Firmware Command Reference Guide Command ConventionsCommand Response Command Summary Terse VerboseWP n Enter Command Set Enter Enter Command ModeEnter+++Enter Resident Disconnect Sequence ConnectFormat /C x x Enter CP Copy RS232 Port ParametersFormat /CP Enter Third Party DisconnectFormat /D/Y x x Enter 2 Enter or /D/Y 3 EnterErase Buffer Format /E/Y x x EnterDisplay Site ID Default and TestHelp Display Port Status Set Network Port ParametersSet RS232 Port Parameters SD Display Port Diagnostics Reset Network PortSN Display Network Status Save ParametersUF Upgrade Firmware Exit Command ModeFormat /UF Enter Display Port Parameters WhoFormat /X Enter Appendix B. SpecificationsAppendix A. RS232 Port Interface Stop Bits 1 or Appendix C. Customer ServicePower Trademark and Copyright Information Trademarks Used in this Manual