Western Telematic CMS-16 manual Appendix C. Customer Service, Stop Bits 1 or, Power

Page 61

RS232 Port Interface: 16 RS232 serial inputs use DB9 connectors configured as DTE ports.

Network Interface: 10Base-T Ethernet, RJ45

Coding: Asynchronous, 7/8 bits ASCII.

Parity: Even, Odd, None

Stop Bits: 1 or 2.

Data Rate: 300 to 115.2K bps (all standard rates).

Flow Control: XON/XOFF, RTS/CTS, Both, or None.

Timeout: No activity timeout disconnects port. 1, 5, 10, 15, 30 seconds, 1, 5, 15, 30, 90 minutes.

Memory: Stores Parameters and captured data. Non-volatile 512K SRAM buffer memory. Statically allocated.

Break: Accept Break or Refuse Break

Option Switch: 8 position DIP switch, selects default settings for baud rate, flow control, response message format, and command echo.

LEDs: Power On, Ready, Net, Data Activity for Ports 1 through 16.

Temperature: 0°C to 45°C (operating)

Power:

AC Version: IEC-32 Inlet, 115/230 VAC, 50/60 Hz, 5 watts

DC Version: Terminal Strip (#6-32), -48 VDC, 0.2 Amp Max.

Size: 2.8" x 17" x 6.8" (H x W x D)

Weight: 8 lbs. shipping weight

Humidity: 10 to 90% RH, Non-Condensing

Venting: Side vents are used to dissipate heat generated within the unit. When mounting the unit in an equipment rack, make certain to allow adequate clearance for venting.

Appendix C. Customer Service

Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When calling, please be prepared to give the name and make of the unit, its serial number and a description of its symptoms. If the unit should need to be returned for factory repair it must be accompanied by a Return Authorization number from Customer Service.

WTI Customer Service

5 Sterling

Irvine, California 92618

949-586-9950

Toll Free: 1-800-854-7226 Email: service@wti.com

Image 61
Contents CMS-16 Battery Replacement Nameplate Power WarningRack Mount Installation Table of Contents Page List of Figures AppendicesIntroduction Front Panel Unit DescriptionTypographic Conventions Back Panel Power Cable Receptacle Power SwitchGetting Started Using Other Parameters for this Overview OptionalCommunication Parameters System SetUp Ports Apply Power to the CMSConnecting your PC to the CMS Communicating with the CMS UnitControl Command Menu Display ConfigurationStatus Port Name PasswordConnecting Power to the CMS Unit Hardware InstallationAC Powered Units Configure Option SwitchesDC Powered Units Default Handshake Sw4, Sw5 Default Baud Rate Sw1, Sw2, Sw3Default Response Message Format Sw6 Initialize Unit to Default SettingsDefault Command Echo Sw7 Application Example Connecting Devices to the CMSCMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Supervisor Password Password FunctionsPort Passwords Defining the Site ID and Supervisor PasswordConfiguration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Port Parameters #02Parameters #02 Stop Bits Default =ATZ AT&C1$D2S0=1 Network Port Configuration Menu Telnet Port Parameters Network ParametersPage IP Security Implementing IP SecurityPage Copy Port Parameters Copying Parameters to All PortsSave User Selected Parameters Status ScreensPort Status Screen /S Port Status Screen Supervisor Mode, Defaults Shown Status Mode Buffer CountDiagnostics Port Diagnostics Screen /SDMode BUF CTS Name StatusNetwork Status Screen /SN Network Status LAN Status Port Parameters Screens /WTelnet Port Status CMSRTS/CTS Port Parameters #03Operation Any-to-Any ModePort Connection and Disconnection Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeSending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading CMS Firmware Command Conventions Command Reference GuideCommand Response Terse Verbose Command SummaryWP n Enter Enter Enter Command Mode Command SetEnter+++Enter Resident Disconnect Sequence ConnectCP Copy RS232 Port Parameters Format /C x x EnterFormat /CP Enter Third Party Disconnect2 Enter or /D/Y 3 Enter Format /D/Y x x EnterErase Buffer Format /E/Y x x EnterHelp Default and TestDisplay Site ID Set RS232 Port Parameters Set Network Port ParametersDisplay Port Status Reset Network Port SD Display Port DiagnosticsSN Display Network Status Save ParametersExit Command Mode UF Upgrade FirmwareFormat /UF Enter Display Port Parameters WhoAppendix A. RS232 Port Interface Appendix B. SpecificationsFormat /X Enter Power Appendix C. Customer ServiceStop Bits 1 or Trademarks Used in this Manual Trademark and Copyright Information
Related manuals
Manual 59 pages 31.71 Kb