Western Telematic CMS-16 manual Copying Parameters to All Ports, Copy Port Parameters

Page 33

When using the wild card address "255.255.255.255" to block access by all IP addresses, make certain that at least one higher priority mask permits access by your IP address.

5.6.Copying Parameters to All Ports

The /CP command (Copy Port Parameters) provides a convenient means for selecting identical (or similar) parameters for all CMS RS-232 ports.

When the /CP command is invoked, the unit will display a menu which allows you to select port communication parameters, and then copy them to all CMS RS-232 ports. The Copy Port Parameters menu can be used to set all parameters for all RS-232 Ports, or define only a select group of parameters and then copy them to all ports.

Note:

The /CP command will not copy parameters to the Network Port.

The /CP command is only available in Supervisor Mode.

The Copy Port Parameters Menu will not display the Port Password. This field will read either "undefined" or "defined", depending upon whether or not the Port Password has been specified.

To select common parameters for all CMS RS-232 ports, proceed as follows:

1.Access the CMS command mode. If the password prompt is displayed, key in your Supervisor Level Password.

2.At the command prompt, type /CP and press [Enter], the menu shown in Figure 5.5 will be displayed.

COPY PORT PARAMETERS:

 

1.

Port Name:

 

2.

Password:

(undefined)

3.Baud Rate:

4.Bits/Parity:

5.Stop Bits:

6.Handshake Mode:

7.Port Mode:

74. DTR Output:

8.Supervisor Mode:

9.Logoff Character:

10.Sequence Disconnect:

11.Timeout Disconnect:

12.Response Type:

13.Command Echo:

14.Accept Break:

Image 33
Contents CMS-16 Nameplate Power Warning Battery ReplacementRack Mount Installation Table of Contents Page List of Figures AppendicesIntroduction Unit Description Front PanelTypographic Conventions Back Panel Power Cable Receptacle Power SwitchUsing Other Parameters for this Overview Optional Getting StartedCommunication Parameters System SetUp Ports Apply Power to the CMSConnecting your PC to the CMS Communicating with the CMS UnitControl Command Menu Display ConfigurationStatus Port Name PasswordConnecting Power to the CMS Unit Hardware InstallationConfigure Option Switches AC Powered UnitsDC Powered Units Default Handshake Sw4, Sw5 Default Baud Rate Sw1, Sw2, Sw3Initialize Unit to Default Settings Default Response Message Format Sw6Default Command Echo Sw7 Application Example Connecting Devices to the CMSCMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Supervisor Password Password FunctionsPort Passwords Defining the Site ID and Supervisor PasswordConfiguration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Port Parameters #02Stop Bits Default = Parameters #02ATZ AT&C1$D2S0=1 Network Port Configuration Menu Telnet Port Parameters Network ParametersPage IP Security Implementing IP SecurityPage Copy Port Parameters Copying Parameters to All PortsStatus Screens Save User Selected ParametersPort Status Screen /S Port Status Screen Supervisor Mode, Defaults Shown Status Mode Buffer CountDiagnostics Port Diagnostics Screen /SDMode BUF CTS Name StatusNetwork Status Screen /SN Network Status LAN Status Port Parameters Screens /WTelnet Port Status CMSRTS/CTS Port Parameters #03Any-to-Any Mode OperationPort Connection and Disconnection Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeSaving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading CMS Firmware Command Conventions Command Reference GuideCommand Response Terse Verbose Command SummaryWP n Enter Enter Enter Command Mode Command SetEnter+++Enter Resident Disconnect Sequence ConnectCP Copy RS232 Port Parameters Format /C x x EnterFormat /CP Enter Third Party Disconnect2 Enter or /D/Y 3 Enter Format /D/Y x x EnterErase Buffer Format /E/Y x x EnterDefault and Test HelpDisplay Site ID Set Network Port Parameters Set RS232 Port ParametersDisplay Port Status Reset Network Port SD Display Port DiagnosticsSN Display Network Status Save ParametersExit Command Mode UF Upgrade FirmwareFormat /UF Enter Display Port Parameters WhoAppendix B. Specifications Appendix A. RS232 Port InterfaceFormat /X Enter Appendix C. Customer Service PowerStop Bits 1 or Trademarks Used in this Manual Trademark and Copyright Information
Related manuals
Manual 59 pages 31.71 Kb