Western Telematic CMS-16 manual Enter

Page 42

Character Format (for more information, please refer to Section 5.5.3.):

. Three Characters (Default): Uses the format "[Enter]LLL[Enter]", where L is the selected Logoff Character. The Default Resident Disconnect Sequence is [Enter]+++[Enter].

b.One Character: When the One Character Disconnect Sequence is selected, simply enter the selected Logoff Character once (Default = +). Note that it is not necessary to enter a carriage return before or after the Logoff Character.

c.If the default Resident Disconnect Sequence is not compatible with your application, both the command format and Logoff Character can be redefined via the Port Configuration menus, as described in Section 5.5.

2.Third Party Disconnect: (Supervisor Mode Only) The /D command is issued from your resident port to disconnect two third party ports. For example, if your Resident Port is Port 1, a Third Party Disconnect would be used to disconnect Port 3 from Port 4.

. The /D command uses the format: /D xx XX [Enter], where xx and XX are the numbers of the ports that you wish to disconnect, if an N is entered, the command will disconnect the Network Port.

b.The /D (Disconnect) command can only be invoked by a port with access to Supervisor Level commands.

c.The /D command can specify both connected ports, or either of the two ports. For example, if Port 1 is your resident port, any of the following commands can be used to disconnect Port 3 from Port 4:

/D 3 4 [Enter]

or

/D 3 [Enter]

or

/D 4 [Enter]

3.No Activity Timeout: Providing the Timeout feature is enabled at either connected port, the No Activity Timeout can disconnect Resident Ports, or Third Party Ports.

. RS232 Ports: To configure the Timeout Feature for the RS232 Ports, invoke the /P command to display the Port Configuration Menu for the desired port as described in Section 5.5.3. Option 11 enables and defines the Timeout Feature.

Image 42
Contents CMS-16 Nameplate Power Warning Battery ReplacementRack Mount Installation Table of Contents Page Appendices List of FiguresIntroduction Unit Description Front PanelTypographic Conventions Power Cable Receptacle Power Switch Back PanelUsing Other Parameters for this Overview Optional Getting StartedCommunication Parameters Connecting your PC to the CMS Apply Power to the CMSSystem SetUp Ports Communicating with the CMS UnitCommand Menu Display Configuration ControlPort Name Password StatusHardware Installation Connecting Power to the CMS UnitConfigure Option Switches AC Powered UnitsDC Powered Units Default Baud Rate Sw1, Sw2, Sw3 Default Handshake Sw4, Sw5Initialize Unit to Default Settings Default Response Message Format Sw6Default Command Echo Sw7 Connecting Devices to the CMS Application ExampleCMS Application Example Not to Scale Configuration Access to the CMS Command Mode$ telnet 192.1.1.1 Enter Password Functions Supervisor PasswordDefining the Site ID and Supervisor Password Port PasswordsPort Configuration Configuration Conventions3. RS232 Port Configuration Menus Port ModesPort Parameters #02 CTS/RTSStop Bits Default = Parameters #02ATZ AT&C1$D2S0=1 Network Port Configuration Menu Network Parameters Telnet Port ParametersPage Implementing IP Security IP SecurityPage Copying Parameters to All Ports Copy Port ParametersStatus Screens Save User Selected ParametersPort Status Screen /S Status Mode Buffer Count Port Status Screen Supervisor Mode, Defaults ShownMode BUF CTS Port Diagnostics Screen /SDDiagnostics Name StatusNetwork Status Screen /SN Telnet Port Status Port Parameters Screens /WNetwork Status LAN Status CMSPort Parameters #03 RTS/CTSAny-to-Any Mode OperationPort Connection and Disconnection Disconnecting Ports Enter Defining Hunt Groups Hunt Group ExamplePassive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersSaving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading CMS Firmware Command Reference Guide Command ConventionsCommand Response Command Summary Terse VerboseWP n Enter Enter+++Enter Resident Disconnect Sequence Command SetEnter Enter Command Mode ConnectFormat /CP Enter Format /C x x EnterCP Copy RS232 Port Parameters Third Party DisconnectErase Buffer Format /D/Y x x Enter2 Enter or /D/Y 3 Enter Format /E/Y x x EnterDefault and Test HelpDisplay Site ID Set Network Port Parameters Set RS232 Port ParametersDisplay Port Status SN Display Network Status SD Display Port DiagnosticsReset Network Port Save ParametersFormat /UF Enter UF Upgrade FirmwareExit Command Mode Display Port Parameters WhoAppendix B. Specifications Appendix A. RS232 Port InterfaceFormat /X Enter Appendix C. Customer Service PowerStop Bits 1 or Trademark and Copyright Information Trademarks Used in this Manual