Western Telematic CMS-16 manual Network Parameters, Telnet Port Parameters

Page 29

contact your network administrator for appropriate settings, and then assign parameters as described in this section.

NETWORK PARAMETERS

 

1.

IP Address:

(undefined)

2.

Subnet Mask:

(undefined)

3.

Gateway Address:

(undefined)

4.

IP Security:

Off

TELNET PORT PARAMETERS

 

11.

Port Name:

(undefined)

12.

Supervisor Mode:

Permit

13.

Logoff Character:

+

14.Sequence Disconnect: Three Characters

15.Timeout Disconnect: 5 Min

16.

Response Type:

Verbose

17.

Command Echo:

On

18.

Accept Break:

Yes

Enter: #<CR> to Change,

<ESC> Exit ...

Figure 5.3: Network Parameters Menu (Supervisor Mode Only)

To access the Network Parameters menu, type /N and press [Enter]. The screen shown in Figure 5.3 will be displayed. Note that the Network Parameters menu is only available in Supervisor Mode. The Network Parameters menu offers the following options:

1.IP Address: Defines the IP Address for the CMS unit. Type 1 press [Enter], and follow the instructions in the submenu. (Default = undefined).

2.Subnet Mask: Defines the Subnet Mask for the CMS unit. Type 2 press [Enter], and follow the instructions in the submenu. (Default = undefined).

3.Gateway Address: Defines the Gateway Address for the CMS unit. Type 3 press [Enter], and follow the instructions in the submenu. (Default = undefined).

4.IP Security: Sets up the IP Security feature as described in Section 5.5.5.

11.Port Name: (Up to 16 characters) Assigns a name to the Network Port. (Default = undefined).

12.Supervisor Mode: Permits or denies access to the Supervisor Mode. When enabled (Permit), and the valid Supervisor Password is entered, this port may then issue Supervisor level commands. If disabled (Deny), the port may not enter Supervisor Mode, even when the Supervisor Password is entered. (Default = Permit).

13.Logoff Character: Defines the Logoff Character for the Network Port. The Logoff Character determines the disconnect sequence that is issued at this port in order to

Image 29
Contents CMS-16 Rack Mount Installation Nameplate Power WarningBattery Replacement Table of Contents Page List of Figures AppendicesIntroduction Typographic Conventions Unit DescriptionFront Panel Back Panel Power Cable Receptacle Power SwitchCommunication Parameters Using Other Parameters for this Overview OptionalGetting Started System SetUp Ports Apply Power to the CMSConnecting your PC to the CMS Communicating with the CMS UnitControl Command Menu Display ConfigurationStatus Port Name PasswordConnecting Power to the CMS Unit Hardware InstallationDC Powered Units Configure Option SwitchesAC Powered Units Default Handshake Sw4, Sw5 Default Baud Rate Sw1, Sw2, Sw3Default Command Echo Sw7 Initialize Unit to Default SettingsDefault Response Message Format Sw6 Application Example Connecting Devices to the CMSCMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Supervisor Password Password FunctionsPort Passwords Defining the Site ID and Supervisor PasswordConfiguration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Port Parameters #02ATZ Stop Bits Default =Parameters #02 AT&C1$D2S0=1 Network Port Configuration Menu Telnet Port Parameters Network ParametersPage IP Security Implementing IP SecurityPage Copy Port Parameters Copying Parameters to All PortsPort Status Screen /S Status ScreensSave User Selected Parameters Port Status Screen Supervisor Mode, Defaults Shown Status Mode Buffer CountDiagnostics Port Diagnostics Screen /SDMode BUF CTS Name StatusNetwork Status Screen /SN Network Status LAN Status Port Parameters Screens /WTelnet Port Status CMSRTS/CTS Port Parameters #03Port Connection and Disconnection Any-to-Any ModeOperation Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeRestoring Saved Parameters Saving and Restoring Configuration ParametersSending Parameters to a File Upgrading CMS Firmware Command Conventions Command Reference GuideCommand Response Terse Verbose Command SummaryWP n Enter Enter Enter Command Mode Command SetEnter+++Enter Resident Disconnect Sequence ConnectCP Copy RS232 Port Parameters Format /C x x EnterFormat /CP Enter Third Party Disconnect2 Enter or /D/Y 3 Enter Format /D/Y x x EnterErase Buffer Format /E/Y x x EnterDisplay Site ID Default and TestHelp Display Port Status Set Network Port ParametersSet RS232 Port Parameters Reset Network Port SD Display Port DiagnosticsSN Display Network Status Save ParametersExit Command Mode UF Upgrade FirmwareFormat /UF Enter Display Port Parameters WhoFormat /X Enter Appendix B. SpecificationsAppendix A. RS232 Port Interface Stop Bits 1 or Appendix C. Customer ServicePower Trademarks Used in this Manual Trademark and Copyright Information