Western Telematic CMS-16 manual Set Network Port Parameters, Set RS232 Port Parameters

Page 57

Format: /J [Enter]

Response: Displays Site I.D. Message

/N Set Network Port Parameters

Displays a menu which is used to define communication parameters for the Network Port. Also allows access to the IP Security function, which is used to restrict network access by unauthorized IP addresses. For more information on selecting network parameters, please refer to Section 5.5.4.

Availability: Supervisor Only

Format: /N [Enter]

Response: Displays Network Parameters Menu

/P Set RS232 Port Parameters

Displays a menu which allows the user to select options and parameters for the selected port. Section 5.5.3 describes the procedure for defining port parameters.

Availability: Supervisor Only

Format: /P [x] [Enter]

Where x is the number or name of the port to be configured. If the port number or name is not specified, the CMS will display the configuration menu for your resident port.

Response: The Port Parameters Menu is displayed.

/S Display Port Status

Displays the Port Status Screen, which lists current conditions and parameters for all ports. Normally, the Port Status Screen will not display Port Passwords; the Password column will read either "defined" or "undefined", depending upon whether or not the password for each port has been specified. When the Supervisor Mode is active, the /SP command offers the option to either display or suppress Port Passwords. For more information on the Port Status Screen, please refer to Section 6.1.

Availability: Supervisor / User

Format: /S[P] [Enter]

When the "P" option is included (e.g. /SP), the Port Status Screen will lists the password for each port, if defined. (Supervisor Mode Only).

Response: Displays Port Status Screen

Image 57
Contents CMS-16 Nameplate Power Warning Battery ReplacementRack Mount Installation Table of Contents Page List of Figures AppendicesIntroduction Unit Description Front PanelTypographic Conventions Back Panel Power Cable Receptacle Power SwitchUsing Other Parameters for this Overview Optional Getting StartedCommunication Parameters System SetUp Ports Apply Power to the CMSConnecting your PC to the CMS Communicating with the CMS UnitControl Command Menu Display ConfigurationStatus Port Name PasswordConnecting Power to the CMS Unit Hardware InstallationConfigure Option Switches AC Powered UnitsDC Powered Units Default Handshake Sw4, Sw5 Default Baud Rate Sw1, Sw2, Sw3Initialize Unit to Default Settings Default Response Message Format Sw6Default Command Echo Sw7 Application Example Connecting Devices to the CMSCMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Supervisor Password Password FunctionsPort Passwords Defining the Site ID and Supervisor PasswordConfiguration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Port Parameters #02Stop Bits Default = Parameters #02ATZ AT&C1$D2S0=1 Network Port Configuration Menu Telnet Port Parameters Network ParametersPage IP Security Implementing IP SecurityPage Copy Port Parameters Copying Parameters to All PortsStatus Screens Save User Selected ParametersPort Status Screen /S Port Status Screen Supervisor Mode, Defaults Shown Status Mode Buffer CountDiagnostics Port Diagnostics Screen /SDMode BUF CTS Name StatusNetwork Status Screen /SN Network Status LAN Status Port Parameters Screens /WTelnet Port Status CMSRTS/CTS Port Parameters #03Any-to-Any Mode OperationPort Connection and Disconnection Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeSaving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading CMS Firmware Command Conventions Command Reference GuideCommand Response Terse Verbose Command SummaryWP n Enter Enter Enter Command Mode Command SetEnter+++Enter Resident Disconnect Sequence ConnectCP Copy RS232 Port Parameters Format /C x x EnterFormat /CP Enter Third Party Disconnect2 Enter or /D/Y 3 Enter Format /D/Y x x EnterErase Buffer Format /E/Y x x EnterDefault and Test HelpDisplay Site ID Set Network Port Parameters Set RS232 Port ParametersDisplay Port Status Reset Network Port SD Display Port DiagnosticsSN Display Network Status Save ParametersExit Command Mode UF Upgrade FirmwareFormat /UF Enter Display Port Parameters WhoAppendix B. Specifications Appendix A. RS232 Port InterfaceFormat /X Enter Appendix C. Customer Service PowerStop Bits 1 or Trademarks Used in this Manual Trademark and Copyright Information