Western Telematic CMS-16 Format /C x x Enter, CP Copy RS232 Port Parameters, Format /CP Enter

Page 54

Establishes a bi-directional connection between two ports. For more information and command line examples, please refer to Section 7.1. There are two different types of port connections:

Resident Connect: If the /C command specifies one port name or number, your resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two port names or numbers, the unit will connect the two ports indicated. A Third Party Connect command must be issued from a third port with "Supervisor" command capability. "User" ports cannot initiate a Third Party Connect.

Note:

Ports with "User" command capability can only connect to ports that share the same Port Password.

Ports with "Supervisor" command capability are allowed to connect to all other ports.

Availability: Supervisor / User

Format: /C <x> [x] [Enter]

Where x is the number or name of the port(s) to be connected.

Response:

Verbose: Connected xx, when a Resident Connection is initiated, the CMS will also display the currently selected Resident Disconnect Sequence for your port.

Terse: 1

/CP Copy RS232 Port Parameters

Allows quick set-up when all CMS RS232 ports will be configured with the same or similar parameters. When the /CP command is invoked, the CMS will display a menu that is used to select common port parameters, which can then be copied to all CMS RS232 ports. For more information, please refer to Section 5.6.

Availability: Supervisor Only

Format: /CP [Enter]

Response: Displays Copy Parameters Menu

/D Third Party Disconnect

Invoke the /D command at your resident port to disconnect two other ports. The /D command cannot be used to disconnect your resident port. To disconnect your resident port, issue the

Image 54
Contents CMS-16 Nameplate Power Warning Battery ReplacementRack Mount Installation Table of Contents Page Appendices List of FiguresIntroduction Unit Description Front PanelTypographic Conventions Power Cable Receptacle Power Switch Back PanelUsing Other Parameters for this Overview Optional Getting StartedCommunication Parameters Connecting your PC to the CMS Apply Power to the CMSSystem SetUp Ports Communicating with the CMS UnitCommand Menu Display Configuration ControlPort Name Password StatusHardware Installation Connecting Power to the CMS UnitConfigure Option Switches AC Powered UnitsDC Powered Units Default Baud Rate Sw1, Sw2, Sw3 Default Handshake Sw4, Sw5Initialize Unit to Default Settings Default Response Message Format Sw6Default Command Echo Sw7 Connecting Devices to the CMS Application ExampleCMS Application Example Not to Scale Configuration Access to the CMS Command Mode$ telnet 192.1.1.1 Enter Password Functions Supervisor PasswordDefining the Site ID and Supervisor Password Port PasswordsPort Configuration Configuration Conventions3. RS232 Port Configuration Menus Port ModesPort Parameters #02 CTS/RTSStop Bits Default = Parameters #02ATZ AT&C1$D2S0=1 Network Port Configuration Menu Network Parameters Telnet Port ParametersPage Implementing IP Security IP SecurityPage Copying Parameters to All Ports Copy Port ParametersStatus Screens Save User Selected ParametersPort Status Screen /S Status Mode Buffer Count Port Status Screen Supervisor Mode, Defaults ShownMode BUF CTS Port Diagnostics Screen /SDDiagnostics Name StatusNetwork Status Screen /SN Telnet Port Status Port Parameters Screens /WNetwork Status LAN Status CMSPort Parameters #03 RTS/CTSAny-to-Any Mode OperationPort Connection and Disconnection Disconnecting Ports Enter Defining Hunt Groups Hunt Group ExamplePassive Mode Buffer ModeReading Data from Buffer Mode Ports Xx EnterModem Mode Port BuffersSaving and Restoring Configuration Parameters Sending Parameters to a FileRestoring Saved Parameters Upgrading CMS Firmware Command Reference Guide Command ConventionsCommand Response Command Summary Terse VerboseWP n Enter Enter+++Enter Resident Disconnect Sequence Command SetEnter Enter Command Mode ConnectFormat /CP Enter Format /C x x EnterCP Copy RS232 Port Parameters Third Party DisconnectErase Buffer Format /D/Y x x Enter2 Enter or /D/Y 3 Enter Format /E/Y x x EnterDefault and Test HelpDisplay Site ID Set Network Port Parameters Set RS232 Port ParametersDisplay Port Status SN Display Network Status SD Display Port DiagnosticsReset Network Port Save ParametersFormat /UF Enter UF Upgrade FirmwareExit Command Mode Display Port Parameters WhoAppendix B. Specifications Appendix A. RS232 Port InterfaceFormat /X Enter Appendix C. Customer Service PowerStop Bits 1 or Trademark and Copyright Information Trademarks Used in this Manual