Page 55

Resident Disconnect Sequence or wait for the Timeout Period to elapse (if enabled).

Availability: Supervisor Only

Format: /D[/Y] <x> [x] [Enter]

Where:

/Y (Optional) suppresses the "Sure?" prompt.

xIs the number or name of the port(s) to be disconnected. To Disconnect all ports, enter an asterisk. To disconnect the Network Port, enter an "N".

Response:

Verbose: "Are you Sure (y/n)?", if Y, unit will respond with "Disconnected".

Terse: 5, if Y, unit will respond with 3.

Example: To disconnect Port 2 from Port 3 without the "Sure?" prompt, access the Command Mode from a third port with "All" command capability and type one of the following commands:

/D/Y 2 [Enter] or /D/Y 3 [Enter]

/E Erase Buffer

Erases data from the buffer for a specified port or several ports. Note that erased data cannot be recovered.

Availability: Supervisor Only

Format: /E[/Y] <x> [x] [Enter]

Where:

xIs the number or name of the port buffer(s) to be cleared. To erase buffers for all ports, enter an asterisk.

/Y (Optional) Suppresses the "SURE? (Y/N)" prompt.

Response:

Verbose: "Are You Sure (y/n)?", if Y, the unit will respond with "OK".

Terse: 5, if Y, the unit will respond with 0.

Example: To clear the buffer for Port 3, access the Command Mode from a port with "All" command capability, and type /E 3 [Enter].

/F Set System Parameters

Displays a menu which is used to define the Site ID message and Supervisor Password. When the Supervisor Password is defined, the CMS will display a password prompt before allowing

Image 55
Contents CMS-16 Battery Replacement Nameplate Power WarningRack Mount Installation Table of Contents Page List of Figures AppendicesIntroduction Front Panel Unit DescriptionTypographic Conventions Back Panel Power Cable Receptacle Power SwitchGetting Started Using Other Parameters for this Overview OptionalCommunication Parameters Communicating with the CMS Unit Apply Power to the CMSSystem SetUp Ports Connecting your PC to the CMSControl Command Menu Display ConfigurationStatus Port Name PasswordConnecting Power to the CMS Unit Hardware InstallationAC Powered Units Configure Option SwitchesDC Powered Units Default Handshake Sw4, Sw5 Default Baud Rate Sw1, Sw2, Sw3Default Response Message Format Sw6 Initialize Unit to Default SettingsDefault Command Echo Sw7 Application Example Connecting Devices to the CMSCMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Supervisor Password Password FunctionsPort Passwords Defining the Site ID and Supervisor PasswordConfiguration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Port Parameters #02Parameters #02 Stop Bits Default =ATZ AT&C1$D2S0=1 Network Port Configuration Menu Telnet Port Parameters Network ParametersPage IP Security Implementing IP SecurityPage Copy Port Parameters Copying Parameters to All PortsSave User Selected Parameters Status ScreensPort Status Screen /S Port Status Screen Supervisor Mode, Defaults Shown Status Mode Buffer CountName Status Port Diagnostics Screen /SDDiagnostics Mode BUF CTSNetwork Status Screen /SN CMS Port Parameters Screens /WNetwork Status LAN Status Telnet Port StatusRTS/CTS Port Parameters #03Operation Any-to-Any ModePort Connection and Disconnection Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeXx Enter Reading Data from Buffer Mode PortsPort Buffers Modem ModeSending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading CMS Firmware Command Conventions Command Reference GuideCommand Response Terse Verbose Command SummaryWP n Enter Connect Command SetEnter Enter Command Mode Enter+++Enter Resident Disconnect SequenceThird Party Disconnect Format /C x x EnterCP Copy RS232 Port Parameters Format /CP EnterFormat /E/Y x x Enter Format /D/Y x x Enter2 Enter or /D/Y 3 Enter Erase BufferHelp Default and TestDisplay Site ID Set RS232 Port Parameters Set Network Port ParametersDisplay Port Status Save Parameters SD Display Port DiagnosticsReset Network Port SN Display Network StatusDisplay Port Parameters Who UF Upgrade FirmwareExit Command Mode Format /UF EnterAppendix A. RS232 Port Interface Appendix B. SpecificationsFormat /X Enter Power Appendix C. Customer ServiceStop Bits 1 or Trademarks Used in this Manual Trademark and Copyright Information