Omnitron Systems Technology 2FXM2 user manual Passwords

Page 10

3.4CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

PI

SA

To configure, attach the 2FXM2 to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The 2FXM2 Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the 2FXM2. This is a standard asynchronous serial interface. The pin-outs are illustrated below.

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the 2FXM2 module and press <ENTER> to bring up a command line prompt on the attached PC.

The module is configured with the following defaults:

IP

 

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

 

Serial:

No password assigned

FTP:

No password assigned

Telnet:

public

SNMPv1/v2c Communities

READ:

public

 

 

WRITE:

public

 

 

SNMPv3 Parameters

 

 

 

User 1 name (read only):

guest

 

 

User 2 name (read/write):

admin

 

 

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin

Page 10

Image 10
Contents Standalone and PLUG-IN Module Table of Contents Overview Plug-InPort Structure Installation Procedure B B B B B B BThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan BP B PvidBP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 2FXM2 Specifications Cable TypesTroubleshooting Guide Possible CausesWarranty Limitation of Warranty