Switch 1
Switch 8 Switch 1
Switch 8
Left
3.2.1Board-Mounted Bank 1 Settings
DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right refers to the plug-in module and Down and Up refers to the standalone module.
| Switch | Left/Down | Right/Up |
| (Factory Default) |
| | |
| SW1 | Off: | On: |
| Pause Disable | Pause Enable |
| |
| SW2 | FDX: | HDX: |
| Fiber Port 1 Full-Duplex | Fiber Port 1 Half-Duplex |
| |
| SW3 | Reserved | Reserved |
| SW4 | Reserved | Reserved |
| SW5 | FDX: | HDX: |
| Fiber Port 2 Full-Duplex | Fiber Port 2 Half-Duplex |
| |
| SW6 - SW8 | See Link Mode DIP-Switch Table in Section 3.2.1.6 |
| | | |
3.2.1.1SW1 - Pause Disable/Enable “Off/On”
Pause operation is based on the Pause Disable/Enable DIP-switch setting. Setting the Pause DIP-switch to the “Off” position (factory default) forces the port to operate in No Pause mode. Setting the Pause DIP-switch to the “On” position allows the port to operate in Symmetrical Pause mode.
3.2.1.2SW2 - Fiber Port 1 Full/Half-Duplex “FDX/HDX”
When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port will facilitate a connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports only Half-Duplex.
3.2.1.3SW3, SW4 - Reserved
These DIP-switches are for factory use only.