Omnitron Systems Technology 2FXM2 user manual These DIP-switches are for factory use only

Page 6

Switch 1

Switch 8 Switch 1

Switch 8

Left

Bank 2

Bank 1

Right

DIP-switch Locations

3.2.1Board-Mounted Bank 1 Settings

PI

SA

DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right refers to the plug-in module and Down and Up refers to the standalone module.

PI

(Left/Right)

SA

(Up/Down)

Switch

Left/Down

Right/Up

(Factory Default)

 

 

SW1

Off:

On:

Pause Disable

Pause Enable

 

SW2

FDX:

HDX:

Fiber Port 1 Full-Duplex

Fiber Port 1 Half-Duplex

 

SW3

Reserved

Reserved

SW4

Reserved

Reserved

SW5

FDX:

HDX:

Fiber Port 2 Full-Duplex

Fiber Port 2 Half-Duplex

 

SW6 - SW8

See Link Mode DIP-Switch Table in Section 3.2.1.6

 

 

 

3.2.1.1SW1 - Pause Disable/Enable “Off/On”

Pause operation is based on the Pause Disable/Enable DIP-switch setting. Setting the Pause DIP-switch to the “Off” position (factory default) forces the port to operate in No Pause mode. Setting the Pause DIP-switch to the “On” position allows the port to operate in Symmetrical Pause mode.

3.2.1.2SW2 - Fiber Port 1 Full/Half-Duplex “FDX/HDX”

When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port will facilitate a connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports only Half-Duplex.

3.2.1.3SW3, SW4 - Reserved

These DIP-switches are for factory use only.

Page 6

Image 6
Contents Standalone and PLUG-IN Module Table of Contents Overview Plug-InPort Structure Installation Procedure B B B B B B BThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan BP B PvidVlan ID VID BP a BP BVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 2FXM2 Specifications Cable TypesTroubleshooting Guide Possible CausesWarranty Limitation of Warranty