Omnitron Systems Technology 2FXM2 DIP-switch Bank 2 is only available on the plug-in module

Page 8

3.2.2Board-Mounted Bank 2 Settings

PI

DIP-switch Bank 2 is only available on the plug-in module.

Switch

Left (Factory Default)

Right

SW1

A-DS:

A-EN:

 

Backplane Port A Disabled

Port A Enabled

SW2

B-DS:

B-EN:

 

Backplane Port B Disabled

Port B Enabled

SW3

Reserved

Reserved

SW4

M/SL:

SL:

 

Master/Slave Auto-Select

Slave-Mode Only

SW5 - SW8

Reserved

Reserved

3.2.2.1SW1 - Backplane Port A Enabled “A-DS/A-EN”

When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the 2FXM2 is isolated from the chassis Backplane. When the DIP-switch is in the Right “A-EN” position, Backplane Port A of the 2FXM2 is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port A. See the backplane illustrations in Section 2.1.3.

3.2.2.2SW2 - Backplane Port B Enabled “B-DS/B-EN”

When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the chassis Backplane. When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B. See the backplane illustrations in Section 2.1.3.

3.2.2.3SW4 - Master/Slave Auto-Select and Slave-Only “M/SL / SL

When multiple management modules such as the iConverter Network Management Module (NMM) and the 2FXM2 (or multiple self-managed modules such as the 2FXM2) are installed in the same chassis, only one management module can act as the chassis master. The master management module has the ability to make changes to the settings of the other modules in the chassis, while the slave management modules cannot make the changes. If an NMM is installed in the chassis, the NMM will always be the master, otherwise the lowest slot number with a management module installed will become chassis master.

When this DIP-switch is in the Left “M/SL” position (factory default), the assignment of mastership is automatically negotiated by the installed management modules. To designate a specific management module as the master when no NMM is installed in the chassis, set the DIP-switch on the master module to the Left “M/SL” position, and set the other installed management modules’ DIP-switches to the Right “SL” position to enable Slave-Only mode.

Only the chassis master can change configuration settings of other modules.

3.2.2.4SW3, SW5, SW6, SW7, SW8 - Reserved

These DIP-switches are for factory use only.

NOTE: DIP-switches marked Reserved must be kept in the Left (factory default) position.

Page 8

Image 8
Contents Standalone and PLUG-IN Module Table of Contents Overview Plug-InPort Structure Installation Procedure B B B B B B BThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan BP B PvidVlan Table is Empty Vlan ID VIDBP a BP B Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 2FXM2 Specifications Cable TypesTroubleshooting Guide Possible CausesWarranty Limitation of Warranty