Omnitron Systems Technology 2FXM2 user manual Setting SNMPv1/v2c Read and Write Community Names

Page 16

PI

SA

SNMP Preferences Screen

 

iConverter, Serial Agent

 

Chassis Number

= 1

SNMP Engine ID 80001CAE03000687003B19

1: sysContact

 

Omnitron (949) 250-6510

 

 

2: sysLocation

 

Irvine, CA USA

 

 

3: SNMP Writes

 

Enabled

 

 

 

SNMP v1/v2c -------------------------------------------------------------------

 

 

 

 

4: Read Community

*****

 

 

 

5: Write Community

*****

 

 

 

6: Agent

 

Enabled

 

 

 

SNMP V3 -----------------------------------------------------------------------

 

 

 

 

7: Agent

 

Enabled

 

 

 

8: User 1 name (read only)

guest

 

 

 

9: User 2 name (read/write)

admin

 

 

 

10: User 1 Security

noAuthNoPriv 13: User 2 Security

noAuthNoPriv

11: User 1 Privacy pwd

*****

14: User 2 Privacy pwd

*****

12: User 1 Authen. pwd

*****

15: User 2 Authen. pwd

*****

Traps Hosts -------------------------------------------------------------------

 

 

 

 

16: Address 1

255.255.255.255

20: Address 5

255.255.255.255

17: Address 2

255.255.255.255

21: Address 6

255.255.255.255

18: Address 3

255.255.255.255

22: Address 7

255.255.255.255

19: Address 4

255.255.255.255

23: Address 8

255.255.255.255

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

3.4.2.1Setting SNMPv1/v2c Read and Write Community Names

The 2FXM2 is shipped from the factory with the SNMP agent enabled with the default SNMP Read and Write Community name as “public”. See Section 3.4 for all factory default settings.

The SNMP Read Community Name is necessary for reading data from the 2FXM2. The name can be any 1-32 character alphanumeric string. To set the SNMP Read Community Name, select 4 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts.

The SNMP Write Community Name is necessary for writing data to the 2FXM2. The name can be any 1-32 character alphanumeric string. To set the SNMP Write Community Name, select 5 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.2.2Setting SNMPv3 Parameters

SNMPv3 implements a security model that provides for message integrity, authentication, and encryption.

Authentication for SNMPv3 is provided through a unique User Name and Authentication Password for each access level.

Two access levels or accounts are available; Read-Only Level (User 1) and Read and Write Level (User 2). User 1 is allowed to request information from the module. User 2 is allowed to request information from and set configuration to the module. To set the User 1 name, select 8 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts. To set the User 2 name, select 9 at the SNMP Preferences screen, press <ENTER> and then follow the screen prompts. The 2FXM2 is shipped with default values pre-assigned. See Section 3.4 for all factory default settings.

The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv, authNoPriv and authPriv. noAuthNoPriv uses username for authentication,

Page 16

Image 16
Contents Standalone and PLUG-IN Module Table of Contents Overview Plug-InPort Structure Installation Procedure B B B B B B BThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation Detailed Module Configuration NMM2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan BP B PvidBP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter 2FXM2 Specifications Cable TypesTroubleshooting Guide Possible CausesWarranty Limitation of Warranty