Omnitron Systems Technology 2FXM2 user manual Setting the Chassis Number and Name

Page 13

PI

SA

Management Options

iConverter, Serial Agent

Network Management

1:Chassis and Module Management

2:Set Module Identifier

Management Module Preferences

3:IP and Control Preferences

4:SNMP Preferences

5:Abandon Preference Changes

6:Save Preference Changes

7:Restore to Factory Defaults

8:Restart Management Module

9:Other Networking Features

Management Module Maintenance

10:Firmware Update

11:Set Date/Time

IP Address

= 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 9

PI

SA

Other Networking Features Screen

iConverter, Serial Agent

1:

Enable/Disable DHCP Client

Disabled

2:

Enable/Disable Keep Alive Trap

Disabled

3:

Keep Alive Trap interval (10-600 secs)

10

4:

Enable/Disable SW1 Switch Block

Enabled

5:

Serial Baud Rate

57600 bps

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts to enable DHCP.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.1.3Setting the Chassis Number and Name

A Chassis Name, or sysName, can be assigned for identification of the 2FXM2 in the SNMP client. The name can be any 1-32 character alphanumeric string.

The Chassis Number can remain as 1 (factory default) when the 2FXM2 is installed without an iConverter NMM in the same chassis. When the 2FXM2 is installed in the same chassis as an NMM, then the 2FXM2 must be set to the Chassis Number of the NMM.

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis number.

To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name.

NOTE: When the NMM is installed into the chassis and is set to Remote OAM, the chassis number of the 2FXM2 is automatically assigned by the NMM.

Page 13

Image 13
Contents Standalone and PLUG-IN Module Table of Contents Plug-In OverviewPort Structure B B B B B B B Installation ProcedureThese DIP-switches are for factory use only 1.5 SW5 Fiber Port 2 Full/Half Duplex FDX/HDX DIP-switch Bank 2 is only available on the plug-in module Installing PLUG-IN Modules and Connecting Cables Passwords Management Options screen will be displayed 2FXM2 Setting the Chassis Number and Name Setting 2FXM2 Passwords Setting Snmp Preferences Setting SNMPv1/v2c Read and Write Community Names Setting the Snmp Trap IP Host Addresses Enabling/Disabling Soft-switch Reload Access the 2FXM2 Remotely Updating the 2FXM2 Firmware via the Serial Console Port Verify Operation NMM Detailed Module Configuration2FXM2 LED Module Management Mode Port Configuration Port Access To change the ingress rate of the Port 1, select option SFP Information 5 802.3ah Parameters Local Status Section OUI 6 802.3ah Events Port Vlan Off Tagged Vlan Pvid BP BBP a BP B Vlan ID VIDVlan Table is Empty Vlan ID +1 Vlan ID CNode Loopback To refresh the Port Statistic screen, press Enter Cable Types 2FXM2 SpecificationsPossible Causes Troubleshooting GuideLimitation of Warranty Warranty